- 16 -
Mode No. EXP-value, and measurement time unit setting
A B C D E F
0 2.3 0 1 1
Display decimal point setting
0・・・ 0
1・・・ 0.0
2・・・ 0.00
3・・・ 0.000
4・・・ 0.0000
measurement time unit
0 ・・・ per Hour
1 ・・・ per Minute
2 ・・・ per Second
Display condition for last figures
0 ・・・ real display
1 ・・・ "0" fixed
2 ・・・ only "0" or "5" display
EXP-value
0-9
0 2
This mode “02" -C is EXP-value input as explained in mode “01" .
Mode No. Display sampling time
A B C D E F
0 3. 0 2.0
Sampling time
00.1~99.9 seconds
(00.0 corresponds to 100 sec.)
0 3
For display-sampling time, input signal is measured with its set time, and its mean
value is calculated and display, then use it for preventing the flashing or for
stabilizing the display. Accordingly, renewal shall be made by averaging the display
for each set time.