- 52 -
A B C D E
Measurement indicat
1 2 3 4
○ ○ ○ ○
Hold %
○ ○
After the end of registration, if a is pressed 2 sec
or more, it will shift to a measurement.
Or please re-switch on a power.
In the case of AI (4 to 20mA) output In the case of AV3 (1 to 5V) output
Adjustment item
Current value
Adjustment item
Voltage value
Minimum adjustment
4.000mA
Minimum adjustment
1.000V
Maximum adjustment
20.000mA
Maximum adjustment
5.000V
In the case of AV4 (0 to 5V) output In the case of AV5 (0 to 10V) output
Adjustment item
Voltage value
Adjustment item
Voltage value
Minimum adjustment
0.000V
Minimum adjustment
0.000V
Maximum adjustment
5.000V
Maximum adjustment
10.000V
About operating flow detail, refer to “Analog adjustment flow chart”.