![background image](http://html1.mh-extra.com/html/uic/bezel-5/bezel-5_programmers-manual_3278495076.webp)
UIC Bezel5 Programmer’s Manual
Page.76/166
UDN PM098 Rev. 1.0
Copyright © 2013, Uniform Industrial Corp. All Rights Reserved
4.3.4.
CPx(43h 50h x)
-
PayPass Support
Command Packet
Byte 0 ~ 1
Byte 2
CP
Command Type, see Table 4-28
Command Type
Parameter
Example (Hex)
Description
00h
09h 00h 03h 43h 50h 00h 19h
MagStripe Only
01h
09h 00h 03h 43h 50h 01h 18h
MChip Enable
Table 4-28. Configure PayPass supporting mode
4.3.5.
CTx(43h 54h x)
-
Set Terminal/Transaction Type/Info
Command Packet
Byte 0 ~ 1
Byte 2
Byte 3
CT
Type
Data, see Table 4-29
Command Type
Parameter
Length
Description
Example (Hex)
0
1 Byte
Terminal Type
09h 00h 04h 43h 54h 30h 22h 08h
1
1 Byte
Transaction Type
09h 00h 04h 43h 54h 31h 00h 2Bh
2
1 Byte
Transaction Info
09h 00h 04h 43h 54h 32h 40h 68h
Table 4-29. Set Terminal, Transaction Type/Info Table
4.3.6.
DFx(44h 46h x)
-
Default Setting
The reader will restore the configuration to default manufacture settings after receiving this
command.
Command Packet
Byte 0 ~ 1
Byte 2
DF
<00>
Important: It has to power-cycle the reader after this command is processed.