UIC Bezel5 Programmer’s Manual
Page.56/166
UDN PM098 Rev. 1.0
Copyright © 2013, Uniform Industrial Corp. All Rights Reserved
54 (35H34H) - Set Date
Command Packet:
Byte 0-1
Byte 2-3
Byte 4
Byte 5
Byte 6
Command
Year
Month
Date
Week
54
<14><0C>
<0C>
<06>
<04>
Hex value format valid input
01h=Monday, 02h=Tuesday, … 07h=Sunday
Default setting is <20><01><01><01><01>, obtained by Read Date.
YYYY: 14h 00h – 1Eh FFh (2000 – 3000)
If the ‘YYYY’ falls out of range, the reader will restore the configuration to default settings after resetting the device.
Example
Host Command
Reader Response Example
54<14><0C><0C><06><04>
^
55 (35H35H) - Set Time
Command Packet:
(
Hex value format valid input)
Byte 0-1
Byte 2
Byte 3
Byte 4
Byte 5-6
Command
Hour
Min
Second
Millisecond
55
<11>
<0E>
<37>
<00><0A>
Example
Host Command
Reader Response Example
55<11><0E><37><00><0A>
^