UIC Bezel5 Programmer’s Manual
Page.71/166
UDN PM098 Rev. 1.0
Copyright © 2013, Uniform Industrial Corp. All Rights Reserved
Example
Host Command
Reader Response Example
P
^
Note:
1.
After an Arm to Read command is received and acknowledged the only valid commands that
will be accepted for execution are: <ESC> “Abort” and ‘$’ “Status”.
2.
Reader will NOT send out track data automatically; the host has to issue the ‘Q’, ‘R’, ‘S’
commands to get the corresponding track data.
3.
In the Self-Arm mode, it is not necessary to send this command. If this command is sent, it will
temporarily override the Self-Arm mode.
4.2.3.
p (70H) – Arm to Read (Used for Manufacturing Test Only)
Equivalent to the 'P' command, except that the card read acknowledgement is not the ‘^’ character.
Example
Host Command
Reader Response Example
p
^
It will report a ‘(‘ (28H) byte if the card media is detected, and a ‘)’ (29H) byte when the media
detection goes inactive.
4.2.4.
<ESC> (1BH) – Abort Arm to Read
1.
Clear the data buffers.
2.
Aborts the Arm to Read command.
Example
Host Command
Reader Response Example
<1B>
^