CX6182
O
PERATION
16
6
Operation
6.1
Automatic wake up
The knob cylinder is in sleep mode as long as it is not used. To check the
authorization of a key, it needs to be woken up from the sleep mode. This
normally happens automatically if a key is held in front of the reader unit.
If, however, the electronic knob cylinder has been woken up 24 times (for
example by metallic objects in the surroundings) without reading a key, then
automatic wake up is disabled.
In this case, the knob cylinder has to be woken up manually.
Turn the knob module few times to wake up the reading unit
,
until an LED
starts glowing.
Hold up an authorized key in front of the reading unit only after this.
Automatic wake up is enabled once again by reading an authorized key, but it
can also be enabled or disabled using the service device CX6510.
In addition, the wake up sensitivity (that is the number of times the knob module
needs to be turned to wake up the reading unit) can be set.
6.2
Opening the door
Hold the authorized key in front of the reading unit until the green LED starts
glowing.