Intended use

Table of contents

How it works

Intended use

How it works

Safety instructions

Operating the device

Technical information

Cleaning and care

Warranty

Important patient information
Important technical information

Device description
Display
Initial commissioning of the device
Setting the date, time and temperature unit (°C/°F)
Switching the beep on/off
Avoiding inaccurate measurements
Measuring the temperature
Classifying the measured values

Retrieving saved readings

Extended measuring range

Deleting the measured value memory
Replacing the battery

Error messages
Technical data

Metrological inspection
Explanation of symbols

Customer service

Disposal

3

3

5
6

7
8
9
9

10
11
12
14
15
16
17
17

19
20
21
21
22
22

23

24

Domotherm

®

 E is an electronic infrared thermometer for regular meas-

urement and monitoring of the human body temperature in the ear 
canal. It is suitable for adults and children from the age of 6 months.

The device measures the infrared energy that is emitted by the middle 
ear and the surrounding tissue. A sensor takes this thermal radiation 
and converts it into temperature values. The measured temperature 
appears on the display.

Measurements taken on the surrounding tissue of the ear canal will 
result in lower measured values and can lead to an incorrect diagnosis 
of a fever. You should therefore follow the instructions on avoiding 
inaccurate measurements on page 11.

The innovative infrared technology enables the body temperature to 
be measured in just one second. This makes it particularly suitable for 
use with children. A measurement can even be taken as a child sleeps 
without disturbing them.

Its ergonomic design makes the thermometer easy and convenient 
to use.

It features a measured value memory that stores the last 12 measured 
temperature values along with the date and time of the measure-
ment. This allows you to track the change in temperature over time.

The thermometer has no probe cover, making it particularly us-
er-friendly and cost-effective. As no replacement probe covers need 
to be purchased, there are no follow-up costs.

Fever alarm: If temperature values above 37.5 °C are measured, then 
three short beeps and a red background light on the display indicate 
that this is a raised temperature.

Содержание Domotherm E

Страница 1: ...Instructions for use www domotherm de...

Страница 2: ...ounding tissue A sensor takes this thermal radiation and converts it into temperature values The measured temperature appears on the display Measurements taken on the surrounding tissue of the ear can...

Страница 3: ...a high level of humidity Read these instructions for use carefully to ensure that you have un derstood all of the functions and the safety information Take the time to familiarise yourself with the t...

Страница 4: ...rowaves or other devices with strong electromagnetic fields can cause mal functions Maintain a distance of at least one metre from such de vices when using the thermometer If you cannot maintain the m...

Страница 5: ...for entering the basic settings date time temperature unit Before using the device for the first time set the date and time so that the measurements can be saved together with the date and time During...

Страница 6: ...ounding tissue of the ear canal will result in lower measured values and can lead to an incorrect diagnosis of a fever For this reason it is very important to position the thermometer in the ear corre...

Страница 7: ...hes back to measuring mode Figure 5 Performing measurement The best way to perform the measurement on small children is to lie them flat on their stomach with their head facing to the side so that the...

Страница 8: ...the normal body temperature varies de pending on where the measurement is taken Caution It is essential to consult a doctor in cases of high fever 37 5 C to 38 0 C high temperature 38 0 C to 39 0 C m...

Страница 9: ...CR2032 lithium battery If the battery icon flashes on the display while the thermometer is in use the battery is low Although you are still able to take tempera ture measurements you should have a sp...

Страница 10: ...Cover of battery compartment unlocked Cover of battery compartment locked Error messages Measured temperature is above 100 0 C and is therefore outside the measuring range Measured temperature is bel...

Страница 11: ...re to operating temperature 2 hours Customer service Metrological inspection Device repairs may only be performed by the manufacturer or an ex pressly authorised body Please contact In accordance with...

Страница 12: ...C 25 C 95 15 IP 22 Disposal Technical equipment and batteries do not belong in household waste They must be disposed of at appropriate collection and disposal points Use one of the enclosed alcohol w...

Страница 13: ...device by the buyer Further more the warranty does not constitute grounds for asserting claims for damages against us UEBE Medical GmbH Service Center Zum Schlag 18 97877 Wertheim Germany Warranty cla...

Страница 14: ......