IM_ONE-01
1
www.ueonline.com
One Series Electronic Pressure
and Temperature Switches
Discrete Input and Loop-Powered
Models: 2W2D, 2W3A, 2WLP
External Powered
Models: 4W3A, 8W2D
U N I T E D E L E C T R I C
C O N T R O L S
Installation and Maintenance
Instructions
Please read all instructional literature carefully and thoroughly before starting. Refer to the final page for the listing of Recommended
Practices, Liabilities and Warranties.
IM_ONE-01
GENERAL
MISUSE OF THIS PRODUCT MAY CAUSE EXPLOSION AND PERSONAL INJURY. THESE INSTRUCTIONS MUST BE THOROUGHLY READ AND UNDERSTOOD
BEFORE UNIT IS INSTALLED.
WARNING: EXPLOSION HAZARD - SUBSTITUTION OF COMPONENTS MAY IMPAIR SUITABILITY FOR USE IN HAZARDOUS LOCATIONS.
WARNING: SEE THE PRODUCT NAMEPLATE INFORMATION FOR SPECIFIC AGENCY CERTIFICATIONS APPLICABLE TO YOUR PRODUCT.
2W2D MODELS
THIS EQUIPMENT IS SUITABLE FOR USE IN CLASS I, DIVISION 2, GROUPS A, B, C AND D; CLASS II, DIVISION 2, GROUPS F AND G; CLASS III; CLASS I, ZONE
2 AEx nC IIC T5; CLASS I, ZONE 2 Ex nC IIC T5; OR CLASS I, DIVISION 1, GROUPS A, B, C AND D; CLASS II, DIVISION 1, GROUPS E, F AND G; CLASS III;
CLASS I, ZONE 0 AEx ia IIC T5; CLASS I, ZONE 0 Ex ia IIC T5; WHEN INSTALLED PER DRAWING #A-62174-19 (NORTH AMERICA); OR NON-HAZARDOUS
LOCATIONS ONLY.
THIS EQUIPMENT IS ATEX CERTIFIED SUITABLE FOR APPROPRIATE USE IN GAS ZONE 2 & DUST ZONE 22 APPLICATIONS OR GAS ZONE 0 & DUST ZONE
20 APPLICATIONS WHEN INSTALLED PER DRAWING #A-62174-20 (EUROPE).
0539 DEMKO 03 ATEX 0322281X
0539 DEMKO 03 ATEX 0322281X
II 1 G EEx ia IIC T5
II 3 G EEx nL IIC T5
II 1 D T+ 90ºC
II 3 D T+ 90ºC
-40ºC TAMB. +85ºC, IP66
-40ºC TAMB. +85ºC, IP66
2W3A MODELS
THIS EQUIPMENT IS SUITABLE FOR USE IN CLASS I, DIVISION 2, GROUPS A, B, C AND D; CLASS II, DIVISION 2, GROUPS F AND G; CLASS III; CLASS I, ZONE
2 AEx nC IIC T5; CLASS I, ZONE 2 Ex nC IIC T5; OR NON-HAZARDOUS LOCATIONS ONLY.
THIS EQUIPMENT IS ATEX CERTIFIED SUITABLE FOR APPROPRIATE USE IN GAS ZONE 2 & DUST ZONE 22 APPLICATIONS.
0539 DEMKO 03 ATEX 135585X
II 3 G EEx nL IIC T5
II 3 D T+ 90ºC
-40ºC ≤ TAMB. ≤ +85ºC, IP66
2WLP AND 8W2D* MODELS
(* pending approvals)
THIS EQUIPMENT IS SUITABLE FOR USE IN CLASS I, DIVISION 2, GROUPS A, B, C AND D; CLASS II, DIVISION 2, GROUPS F AND G; CLASS III; CLASS I, ZONE
2 AEx nC IIC T4 CLASS I, ZONE 2 Ex nC IIC T4; OR NON-HAZARDOUS LOCATIONS ONLY.
THIS EQUIPMENT IS ATEX CERTIFIED SUITABLE FOR APPROPRIATE USE IN GAS ZONE 2 & DUST ZONE 22 APPLICATIONS.
0539 DEMKO 03 ATEX 0322281X
II 3 G EEx nL IIC T4
II 3 D T+ 130ºC
-40ºC ≤ TAMB. ≤ +80ºC, IP66
4W3A MODELS
THIS EQUIPMENT IS SUITABLE FOR USE IN CLASS I, DIVISION 2, GROUPS A, B, C AND D; CLASS II, DIVISION 2, GROUPS F AND G; CLASS III; CLASS I, ZONE
2 AEx nC IIC T4; CLASS I, ZONE 2 Ex nC IIC T4; OR NON-HAZARDOUS LOCATIONS ONLY.
Содержание 2W2D
Страница 13: ...IM_ONE 01 13 www ueonline com PROCESS DISPLAY ...