FRENCH WARNING TRANSLATIONS

Page

Warning Text

Texte d’advertissement

1

Misuse of this product may cause explosion and personal 
injury. These instructions must be thoroughly read and un-
derstood before unit is installed. See the product nameplate 
information for specific agency certifications applicable to 
your product. 

Utilisation abusive de ce produit peut causer une explosion et des 
blessures. Ces instructions doivent être soigneusement lues et com-
prises avant l’ appareil est installé. Voir l’information sur la plaque 
signalétique du produit pour les certifications d’agence spécifiques 
applicables.

1

Substitution of components may impair suitability for use in 
hazardous locations. Cable glands used must be rated for a 
minimum of IP66 in order to maintain the same IP rating. 

La substitution de composants peut nuire à l’aptitude à l’utilisation 
dans des endroits dangereux. Les presse-étoupes utilisés doivent 
avoir un indice de protection IP66 minimum afin de conserver le 
même indice de protection IP.

1

For zone hazardous locations, all cable entry devices shall be 
certified in type of explosion protection flameproof enclosure 
“d” with an IP66 rating suitable for the conditions of use and 
correctly installed. If cables and cable glands are not used, 
a stopping box shall be provided within 2” of the enclosure. 
Flameproof joint and gap details are provided on page 2. 

Pour les zones explosives poussiéreuses, tous les dispositifs 
d’entrée de câble doivent être certifiés dans le type de protection 
de l’ enceinte ignifuge “d” avec un indice de protection IP66, adapté 
aux conditions d’utilisation et correctement installés. Si les câbles 
et presse-étoupes ne sont pas utilisés, une boîte d’arrêt doit être 
fournie dans les 5 cm de l’enceinte. Plus de détails sont fournis à la 
page (2).

1

Install units where shock, vibration and temperature fluctua-
tions are minimal. Orient unit to prevent moisture from enter-
ing enclosure. Use properly rated sealing fittings for electri-
cal wire entry. Do not mount unit in ambient temperatures 
exceeding published limits. This is especially critical for local 
mount temperature units. Use of a shroud is recommended 
where direct sunlight and rain may come in contact with the 
enclosure.

Installez les unités où le choc, vibration et les fluctuations de tem-
pérature sont minimes. Orienter l’unité d’une manière à empêcher 
l’humidité de pénétrer dans l’enceinte. Utiliser des raccords 
d’étanchéité bien notés pour l’entrée de fil électrique. Ne pas monter 
l’unité à des températures ambiantes dépassant les limites publiées. 
Cela est particulièrement important pour les unités de température à 
montage locale. L’utilisation envelopper est recommandée lorsque le 
soleil et la pluie peuvent entrer en contact avec le boîtier.

3

Continuous operation should not exceed the designated over 
range pressure or working pressure range stated within the 
literature and on device nameplate. 

Le fonctionnement continu ne doit pas dépasser la pression de dé-
passement ou la plage de pression de fonctionnement indiquée dans 
la documentation et sur la plaque signalétique de l'appareil.

4

Before installing, check the sensor model selected for compat-
ibility to the process media in contact with the sensor and 
wetted parts.

Avant l’installation, vérifier le modèle de l’appareil sélectionné pour la 
compatibilité avec le fluide du procédé en contact avec le capteur et 
les parties mouillées.

4

In all applications, secure the enclosure as detailed below. Do 
not mount via the process connection only. 

Dans toutes les applications, sécuriser l’enceinte comme détaillé ci-
dessous. Ne pas installer par la connexion de processus seulement.

4

For pressure and local temperature models, always hold a 
wrench on the sensor housing hex when mounting the device. 
Do not tighten by turning the enclosure, as this will damage 
the connection between the sensor and housing. 

Pour tous les modèles de température et pression locaux, toujours 
tenir une clé sur l’hexagone du capteur pendant le montage de 
l’unité. Ne pas serrer en tournant l’enceinte, cela pourrait endom-
mager la connexion entre le capteur et l’enceinte.

4

For differential pressure models (especially low range units), 
mount the sensor level to minimize any pressure reading 
offsets. The offset command may be used to zero the display 
(see page xx for additional information). 

Pour les modèles de pression différentielle (de pressions faibles), 
montez le niveau du capteur afin de minimiser tout décalage de 
lecture de pression. La commande décalée peut être utilisée pour 
mettre l'affichage à zéro (voir la page xx pour plus d'informations).

4

Never insert any object into the pressure sensor opening. 
Damage to the sensor will result, affecting accuracy. 

Ne jamais insérer un objet dans l’orifice du capteur de pression. Les 
dommages à la membrane de capteur se traduira, à affecter la préci-
sion.

Содержание 1XSWHH

Страница 1: ...Ex UL 08 0017X Applicable Standards UL 913 UL 60079 0 UL 60079 11 CSA C22 2 No 157 92 CSA C22 2 No 60079 0 11 CSA C22 2 No 60079 11 14 EN 60079 0 2012 A11 2013 EN 60079 11 2012 IEC 60079 0 Ed 6 2011 06 Corr 1 2012 01 Corr 2 2013 12 IEC 60079 11 Ed 2011 Suitable for appropri ate use in EXIA Intrinsically Safe Sécurité Intrin séque Class I Div 1 Groups A B C D Class II Div 1 Groups E F G Class III C...

Страница 2: ... cover cemented joint 0 753 19 1 mm rabbet spigot minimum length Breather element threaded joint M8 1 25 6g 6H medium fit class 11 threads engaged minimum Electrical conduit threaded joint 3 4 14 NPT 5 threads engaged minimum Enclosure to sensor threaded joint Pressure models 1 20 UNEF 2 10 threads engaged minimum Temperature models 1 2 14 NPT 5 threads engaged minimum Remote and local spring load...

Страница 3: ... 1 A maximum I Am Working IAW The One Series also contains UE s patented IAW self diagnostic software On a continuous basis the IAW algorithm checks for proper opera tion and locally reports the status using messages or revolving arrows on the display For remote reporting a discrete IAW Output signal can be monitored by the control system and used to detect normal tripped and fault conditions IAW ...

Страница 4: ...NEVER INSERT ANY OBJECT INTO THE PRESSURE SENSOR OPENING DAMAGE TO THE SENSOR WILL RESULT AFFECTING ACCURACY Pressure and Differential Pressure Models To pipe mount Thread the pressure connection onto the pressure port with thread sealant making sure that the mating threads are clean and free of debris Use a wrench on the pressure connection hex to tighten Test for leaks On Differential Pressure m...

Страница 5: ...S SHOULD ALSO BE FREE OF DIRT AND OTHER CONTAMINANTS Remove the enclosure cover by turning it counter clockwise for 7 revolutions Figure 2 Carefully remove the display module by grasping the outer edge and pulling it away from the base enclosure Figure 3 being careful not to strain any of the wired connections Allow the display module to hang from the wired connections to access the base enclosure...

Страница 6: ...LL 1XSWLL 1XSWHL 1XSWHL WIRING DIAGRAMS Models 1XSWLL and 1XSWHL Maximum Switch Ratings Flameproof and Non Incendive Model Signal Name Voltage Rating Current Rating 1XSWLL SW 7 8 50 0 VDC 0 1 amperes1 IAW 7 8 50 0 VDC 0 1 amperes1 1XSWHL SW 70 240 VAC VDC 0 1 amperes1 IAW 7 8 50 0 VDC 0 1 amperes1 1XSWHH SW 70 240 VAC 0 150 10 amperes2 IAW 7 8 50 0 VDC 0 1 amperes1 1 Derate at 0 001 amperes per C ...

Страница 7: ...N Connections for the programmable solid state relay switch are made at TB2 terminals A and B refer to table 2 page 6 and table 3 page 8 The wiring diagram below Figure 9 provides a view inside the One Series base enclosure with the display module removed TB2 is located there All models include a separate IAWTM switched output located at TB3 on the back of the display module This signal provides t...

Страница 8: ...ty parameters and wiring information https www ueonline com support product drawings Model 1XSWLL must be wired to an approved I S galvanically isolated barrier for Zone 0 EPL Ga and Class I Division 1 classifications The information provided is for reference only and is intended to act as a guide in the selection of a suitable I S Barrier SUBSTITUTION OF COMPONENTS MAY IMPAIR INTRINSIC SAFETY Ins...

Страница 9: ...utton sets the digit and moves to the next Once a valid password is entered OK will appear on the display Press and release the right g button CLR MAX MIN or MAN RSET if Latch is set will appear on the display This is the first command prompt in the Programming Mode NOTE The One Series will automatically exit the Programming Mode and resume monitoring the process go back online if two minutes elap...

Страница 10: ...ne break The IAW output always operates in DTT mode Please use the Switch Decision Logic Figure 11 page 11 for help with setting the appropriate switch mode Press and release the left 2 button until the desired mode appears Press the right g button to select the mode and move on to the set point SP will appear NOTE The set point is the process value at which the One Series opens or closes the swit...

Страница 11: ...m temperature Example The P15 sensor has a range of 0 to 300 psi When setting a Set Point of 150 the actual switch point may occur between 148 5 and 151 5 due to the accuracy error of 1 5 300 x 0 5 Switch Decision Logic Figure 11 Resetting the Maximum Minimum Values The One Series continuously captures the readings from the sensor and stores one minimum and maximum value since the last time they w...

Страница 12: ...actory setting Press the left 2 button to increment the blink ing digit Press the right g button to enter and move to the next digit Press the right g button to enter the new offset and return to the main menu Adjusting Span SPAN provides an adjustment to shift the slope of the sensor s response curve to accommodate an offset value other than zero To adjust SPAN calculate and enter a new SPAN valu...

Страница 13: ...he process port may be plugged It does this by monitoring the sensor for changes over time The amount of change and the time period are programmable If the process variable does not change by the amount and selected time period the display will indicate PLUG and the IAW Output will open indicating a fault Refer to the Programming Flowchart on page 18 Enter the Programming Mode and press the left 2...

Страница 14: ...le selections are as follows Pressure Models OFF Default Temperature Models 1 2 second 1 4 second 1 second 1 2 second 2 seconds 1 second 2 seconds Using the left 2 button select a time constant Press the right g button to enter the time constant and return to main menu NOTE The One Series typically responds to a process value change in less that 100 milliseconds when the Filter is set to off Using...

Страница 15: ...tibility of the One Series with your PLC DCS or relay we can help Please have the manu facturer s model number ready when you call us In rare cases when the series resistor value is too large and falls out of the Acceptable Range placing another resistor across the input will allow it to work Please call 1 617 923 6977 Inside Sales for assistance 0 2000 4000 6000 8000 10000 12000 14000 16000 18000...

Страница 16: ...r connections E 16 Diagnostic Fault Sensor SHORT A short circuit has been detected on the sensor drive pins 2 3 Diagnostic Fault Sensor Short check all sensor connections E 18 Diagnostic Fault Relay Monitor The relay output fault monitor circuit has detected that the output state of the solid state relay is incorrect This feature must be enabled in the menu Check the wiring connections or dis able...

Страница 17: ...6977 or go online at www UEonline com UUC to obtain a unique unlock code The Kanban number from the product nameplate is required see Figure 13 THIS DOCUMENT IS PROPRIETARY PROPERTY OF UNITED ELECTRIC CONTROLS UNAUTHORIZED USE IS STRICTLY PROHIBITED TOLERANCES ON FRACTIONS 1 64 1 2 0 010 0 005 2 PLACE DEC 3 PLACE DEC ANGLES Page 1 of 1 WARNING AGENCY CRITICAL DOCUMENT NO REVISIONS WITHOUT CERTIFIC...

Страница 18: ...e flash Err OPEN FALL CLOSE RISE CLOSE FALL OPEN OUT OF WINDOW CLOSE OUT OF WINDOW SPH DBH SPL DBL Note Enter Set Point High Dead Band High Set Point Low and Dead Band Low Details of entry are similar above OFST POS NEG Offset out of Range Flash Err 8888 Set Blinking Digit Increments of Blinking Digit Sets Digit and moves to the next SPAN POS NEG SPAN out of Range Flash Err 8888 Set Blinking Digit...

Страница 19: ...PORT 1 2 14 NPT SENSOR PORT 1 20 NPT SENSOR PORT 1 20 NPT SENSOR PORT 111 92 mm 76 2 mm 133 35 mm 12 7 mm SURFACE MOUNTING KIT 6361 704 144 78 mm 134 62 mm 137 16 mm 154 94 mm 134 62 mm 137 16 mm 264 16 mm 203 2 mm 137 16 mm 129 54 mm 134 62 mm 137 16 mm 76 2 mm 92 20 mm 129 54 mm 134 62 mm 137 16 mm 107 95 mm 61 91 mm 158 75 mm 7 11 mm 107 95 mm 76 2 mm 6 35 mm 8 73 mm DIMENSIONAL DRAWINGS GAGE P...

Страница 20: ...ATED CABLE Ø0 125 3 18 mm FOR DC UNITS Ø0 250 6 35 mm 1 2 NPT COMPRESSION FITTING 300 SERIES st st 26 AWG STRANDED TEFLON INSULATION 4 50 114 3 mm FIXED DIM EPOXY SEAL 2 00 50 8 mm FIXED DIM 1 2 14 NPT PIPE NIPPLE 300 SERIES st st 0 50 12 7 mm Temperature Sensors Remote TR1 TRC TH1 THC TC1 TCC SENSOR OPTIONS Spring Loaded Local TTC Fixed Local TL1 TL3 Differential Pressure 1 4 18 NPT MALE BOTH END...

Страница 21: ... minimes Orienter l unité d une manière à empêcher l humidité de pénétrer dans l enceinte Utiliser des raccords d étanchéité bien notés pour l entrée de fil électrique Ne pas monter l unité à des températures ambiantes dépassant les limites publiées Cela est particulièrement important pour les unités de température à montage locale L utilisation envelopper est recommandée lorsque le soleil et la p...

Страница 22: ...s à la terre en utilisant les vis de terre fournies avec l enceinte 5 Field wiring must be rated 105 C minimum For ambient temperatures below 10 C use suitable field wiring Câblage sur le terrain doit être évalué à 105 C minimum Pour une température ambiante inférieure à 10 C utiliser le câblage approprié 5 Models 1XSWLL and 1XSWHL derive their power directly from a PLC DCS discrete input or other...

Страница 23: ...el Electrical ratings stated in literature and on nameplate must not be exceeded Overload on a switch can cause damage even on the first cycle Wire unit accord ing to local and national electrical codes using wire size recommended in installa tion sheet Do not mount unit in ambient temp exceeding published limits LIMITED WARRANTY Seller warrants that the product hereby purchased is upon delivery f...

Отзывы: