background image

15

 

LT6587 Iss 1 (10/13) 

260mmCRS.

30mm

460mm

FIX 4 OFF EYE

BOLTS IN

POSITIONS SHOWN

TENSIONING NUT

CLAMP SCREW

UC Living Rosmore SLIDE CONTROL Installation Instructions

 

 

SECTION NINE To Install the Appliance continued

 

 
GAS CONNECTION FROM THE FRONT 

Connections  may  be  made  from  the  front  of  the  appliance  from  either  the  left,  right  or  centre 
above  the  gas  valve  in  8-mm  diameter  pipe.    If  a  left-hand  connection  is  required  the  tube 
should  be  routed  below  the  gas  control  and  onto  the  inlet  elbow.    The  inlet  elbows  should  be 
rotated to the required position.   A suitable isolating cock should always be fitted in the supply 
feed to the fire to facilitate servicing. 

 

FIXING FIRE INTO OPENING 

Remove  the  paper backing  from the  length of foam  seal and  stick  it  around  the  rear flange of 
fire. If a spacer is going to be used stick the second length (supplied with the spacer kit) around 
the rear face of the spacer unit,  THE FOAM SEAL MUST BE POSITIONED TO  ENSURE AN 
AIR TIGHT SEAL WHEN THE APPLIANCE IS FITTED.  
 

NOTE: -

DO NOT USE PERMANENT SEALING COMPOUNDS 

i.e. 

SILICONE SEALANT

.

 THIS 

COULD  CAUSE  THE  APPLIANCE  TO  BE  DAMAGED  WHEN  IT  IS  REMOVED  FOR 
SERVICING, AND COULD INVALIDATE THE WARRANTY. 
 
If  a  spacer  is  not  being  used,  mark  position  of  flange  hole  in  the  fireplace  front  drill  and  fix 
firebox in position with wall plugs and wood screws. If spacer is being used fix the spacer to the 
fireplace first  with wood screws and wall plugs then screw firebox to spacer box using screws 
provided.  
 

OPTIONAL  CABLE  FIXING  SYSTEM  
(Available  on  request  from  PARAGON 
FIRES) 

(for  use  when  fixing  to  18"  openings  or 
when  it  is  desirable  not  to  drill  the 
fireplace fascia) it may 

not

 be possible to 

use  the  cable  fixing  system  with  some 
pre-cast flues. 
Drill  4  holes  in  the  rear  of  the  fireplace 
opening  in  the  position  shown  and  fix 
securely  the  4  eye  bolt  provided  with 
suitable wall plugs 
 
 
 
Fix  the  fire  casing  back  into  the  opening 
using the cable fixing system as shown in do 
not  cut  off  loose  ends  of  cable  after  fixing, 
coil and tuck carefully back 
Note: when using the cable fixing kit with the 
spacer, fix and seal the spacer to the rear of 
the  appliance  flange  with  the  screws  and 
foam seal provided. 

 
 
 

Содержание Rosmore Slide Control

Страница 1: ...ES USER INSTALLATION MAINTENANCE INSTRUCTIONS Please read these instructions carefully before you start using the appliance Keep this booklet handy for future reference This appliance is for use in GR...

Страница 2: ...ments 13 Clearance to Shelf 13 Clearance to Side of Fire 14 Ventilation 14 SECTION NINE To Install the Appliance 14 Examine Flue Chimney 14 Connecting to the Gas Supply 14 Preparing the Appliance for...

Страница 3: ...andling wash hands and other exposed parts If a vacuum is used for cleaning the fuel bed or cleaning after servicing installation it is recommended that it be of the type fitted with a HEPA filter Dis...

Страница 4: ...eing incorrectly laid This should be checked prior to contacting a service engineer SECTION TWO Operation The full lighting procedure is as follows a Push slide control lever down as far as possible a...

Страница 5: ...oved CARE SHOULD BE TAKEN TO AVOID CONTACT WITH THE REFRACTORY LINING THIS IS A DELICATE SURFACE AND SHOULD NOT BE WIPED OR RUBBED FUEL BED LAYOUT COAL OPTION Coal set provided consists of 6 off shape...

Страница 6: ...and Layout Cont Place the first row of 3 x A and 3 x B overlay loose coals as shown between the front coals and base matrix Make sure that they are stable and DO NOT let them fall down in the gaps be...

Страница 7: ...EE Fuel Bed Cleaning and Layout Cont Add 2 x type B coals and 1 x type A as shown Add the final 3 x B coals as shown The layout is now finished Note Dye is available for touching up coal and liner boa...

Страница 8: ...ilation is provided it should be checked periodically to ensure freedom from obstruction Ventilation in the Republic of Ireland Must be permanent ventilation and must comply with the rules in force an...

Страница 9: ...IANCE MUST ONLY BE INSTALLED IN THE GB OR IRELAND Only to be used in sufficiently ventilated room Read instructions carefully before installation and use The appliance must be installed by a competent...

Страница 10: ...an be installed in the following flues and locations CLASS ONE A conventional brick or stone chimney as used for a solid fuel appliance with a typical effective cross sectional dimension of 225 x 225...

Страница 11: ...must be suitable for the purpose SECTION EIGHT Fireplace Requirements A flat face of 605 mm high x 500 mm wide must be provided around the fireplace opening for the fixing of the appliance to ensure...

Страница 12: ...on of the appliance ensuring it is very visible and it should be positioned at a height were it can clearly be seen on approach Frets and Fascias used for HOLE in the WALL must be compliant with C J F...

Страница 13: ...d normal adventitious room ventilation exists The installer must satisfy this point by carrying out a mandatory spillage test In the Republic of Ireland permanent ventilation must comply with the rule...

Страница 14: ...echanism is swung up to give easy access to the gas connection point as shown Cut a cross slit in the rubber grommet and feed the appliance onto the 8mm gas supply pipe Position the restrictor elbow s...

Страница 15: ...CE IS FITTED NOTE DO NOT USE PERMANENT SEALING COMPOUNDS i e SILICONE SEALANT THIS COULD CAUSE THE APPLIANCE TO BE DAMAGED WHEN IT IS REMOVED FOR SERVICING AND COULD INVALIDATE THE WARRANTY If a space...

Страница 16: ...e Users Section of these instructions ENSURE THE FUEL BED IS PLACED AS INDICATED IN THESE INSTRUCTIONS Flip the slide control lever round so that the rubber capped end is protruding out to the right a...

Страница 17: ...st should be repeated with the fan running If there is a connected room with an extractor fan the test should be repeated with all the doors to that room opened and the extractor fan running COMPLETIO...

Страница 18: ...he loose components have been removed Examine the fuel bed components for signs of cracking and replace if necessary IMPORTANT see fuel bed layout procedure before attempting to replace loose fuel bed...

Страница 19: ...peration 2 for removal of burner and or silencer 3 Disconnect gas connection to injector and gas control 4 Unscrew the locking nut fixing injector to mounting bracket 5 Clean or replace as necessary 6...

Страница 20: ...helpdesk Model UC Living Rosmore Slide Control Serial No This information can be found on the label attached to the packaging and on the data badge which is located on the appliance flange top right b...

Страница 21: ...nual service Engineer Name Gas Safe Registration No Date of Second annual service Engineer Name Gas Safe Registration No Date of Third annual service Engineer Name Gas Safe Registration No Date of For...

Страница 22: ...22 LT6587 Iss 1 10 13...

Страница 23: ...pliance must be installed by a Gas Safe registered person 2 The appliance must be used in accordance with the users instructions 3 The appliance must be serviced annually by a Gas Safe registered pers...

Страница 24: ...24 LT6587 Iss 1 10 13...

Страница 25: ...________________ Address ________________________________ Post Code TELEPHONE No PRODUCT DETAILS Model UC Living Rosmore Slide Control Serial No Date of Purchase This information can be found on the l...

Страница 26: ...LT Iss...

Страница 27: ...27 LT6587 Iss 1 10 13...

Страница 28: ...28 LT6587 Iss 1 10 13...

Страница 29: ...29 LT6587 Iss 1 10 13...

Страница 30: ...30 LT6587 Iss 1 10 13...

Страница 31: ...31 LT6587 Iss 1 10 13...

Страница 32: ...t Burner Tray Box Assembly Slide Control Trim Covers And Instructions Warning Label Fire Guard Fuel Bed Comprises of Base Matrix 4720 Bag Of Coals 6543 Front Coal LH 4723 Front Coal RH 4724 Restrictor...

Отзывы: