![Ublox LISA-U200 FOTA Скачать руководство пользователя страница 74](http://html1.mh-extra.com/html/ublox/lisa-u200-fota/lisa-u200-fota_integration-manual_833803074.webp)
LISA-U2 series - System Integration Manual
UBX-13001118 - R19
Early Production Information
System description
Page 74 of 175
Each USB profile of LISA-U2 module identifies itself by its VID (Vendor ID) and PID (Product ID) combination,
included in the USB device descriptor according to the
USB 2.0 specifications
If the USB interface is connected to the host before the module switch on, or if the module is reset with the USB
interface connected to the host, the VID and PID are automatically updated runtime, after the USB detection.
First, VID and PID are the following:
VID = 0x058B
PID = 0x0041
This VID and PID combination identifies a USB profile where no USB functions are available: AT commands must
not be sent to the module over the USB profile identified by this VID and PID combination.
Then, after a time period (roughly 5 s, depending on the host / device enumeration timings), the VID and PID are
updated to the following ones, which are related to the LISA-U2 module default USB profile:
VID = 0x1546
PID = 0x1102
The default configuration of the USB interface provides 7 USB CDC-ACM modem COM ports:
USB1: AT and data
USB2: AT and data
USB3: AT and data
USB4: GNSS tunneling
USB5: Primary Log (diagnostic purpose)
USB6: Secondary Log (diagnostic purpose)
USB7: SAP (SIM Access Profile)
The user can concurrently use the AT command interface on one CDC, and Packet-Switched / Circuit-Switched
Data communication on another CDC.
Figure 39 (left side) summarizes the USB end-points available with the default USB profile configuration.
The USB interface of the LISA-U2 series can be configured by the AT+UUSBCONF command (for more details see
the
u-blox AT Commands Manual
[2]) to select a different set of USB functions, available in a mutually exclusive
way, and including 1 CDC-ECM for Ethernet-over-USB and 4 CDC-ACM modem COM ports enumerated as
follows:
USB1: AT and data
USB2: GNSS tunneling
USB3: Primary Log (diagnostic purpose)
USB4: SAP (SIM Access Profile)
The default profile of the USB interface cannot be changed on "01", "x2" and "68" product versions
In the case of the USB profile with the set of functions described above, the VID and PID combination is the
following:
VID = 0x1546
PID = 0x1104
Figure 39 (right side) summarizes the USB end-points available with this alternative USB profile configuration.