11
Heating Control H1
Chapter 2
| Commissioning
0°C
2021.09.30
00:00
6. After the initializing process, the symbol for „Calibration“ appears
in the display.
7. The calibration of the H1 starts. The movements of the H1 valve pin
are now adjusted to the radiator valve and a status bar appears.
0°C
2021.09.30
00:00
8. After successful calibration, a checkmark will appear in the display.
0°C
2021.09.30
00:00
If the process fails even after several calibration attempts, there may
be a problem with your heating valve:
•
Your heating valve is stuck so that the H1 cannot move it in
•
Your heating valve is too long or too short so that the H1 cannot
start the calibration process
0°C
2021.09.30
00:00
9. Following the calibration, the device performs the network startup
and tries to connect to an open Zigbee network. This process can
take up to approx. 7 seconds.
Note:
Please make sure that the Zigbee network has been opened
via the app (see point 2).
0°C
2021.09.30
00:00
10. After joining a network successfully, the display will show the cur-
rent target room temperature (center) and the actual room tempe-
rature (bottom right).
11. You can now set your desired room temperature using the rotary
dial.
Note:
Also displayed, is the quality of the Zigbee wireless connec-
tion (top left), the battery status (top right) and the current actual
temperature (bottom right).
Содержание H1
Страница 1: ...Heating Control H1 Manual...
Страница 4: ...4 Heating Control H1 Chapter 1 General...
Страница 8: ...8 Heating Control H1 Chapter 2 Commissioning...
Страница 15: ...15 Heating Control H1 Chapter 3 Set Room Temperature...
Страница 20: ...20 Heating Control H1 Chapter 4 Schedules...
Страница 29: ...29 Heating Control H1 Chapter 5 More Functions and Information...