3.3 Set temperature offset
Depending on the room conditions, the H1 may measure (and display as actual temperature) a temperature that
differs from the real condition in the room:
Furniture or curtains in front of the radiator accumulate the heated air. Then the valve closes too early and the
room remains cold. Conversely, the H1 may be permanently exposed to drafts, for example. The consequence:
The valve remains open although the desired temperature has already been reached - it becomes too warm in
the room.
To compensate for such temperature differences, the H1 offers a correction option of up to +10°C or -10°C.
For example: If it is 3°C warmer in the room than it is displayed on the H1 or in the ubisys app, +3°C must be
entered in the corresponding menu on the H1. If it is 3°C colder in the room, -3°C must be entered.
To enter a temperature offset at the H1, proceed as follows:
Display
Button
Schraubring
Drehrad
Batterie-Schutzfolie
100 mm
55 mm
1. Press and hold the button for 10 seconds to enter the menu mode.
2. By operating the rotary wheel, you can switch between the diffe-
rent menu items.
0°C
2021.09.30
00:00
3. Turn the rotary dial until the symbol for „Temperature offset“ (incl.
temperature) appears in the display.
4. Press the button again to confirm the menu item.
5. The symbol incl. temperature flashes.
6. Now press the rotary dial to set the correction temperature.
7. As soon as you have made your setting, press the button again to
confirm.
8. You will automatically return to the „start page“.
Содержание H1
Страница 1: ...Heating Control H1 Manual...
Страница 4: ...4 Heating Control H1 Chapter 1 General...
Страница 8: ...8 Heating Control H1 Chapter 2 Commissioning...
Страница 15: ...15 Heating Control H1 Chapter 3 Set Room Temperature...
Страница 20: ...20 Heating Control H1 Chapter 4 Schedules...
Страница 29: ...29 Heating Control H1 Chapter 5 More Functions and Information...