3  Product information 

3.1  Introduction 

The most important feature of the FF-series rotisseries is the high functionality with very attractive 

optical effects. That guarantees an optimum food processing and presentation, which is the basis 

for every selling success. 

3.2  Special Features 

  Enamelled execution 

  Optimum grilling result due to movable spits 

  Heat storing cast iron or steel radiators 

  Elegant design by metal decoration 

  Excellent flame optical effect by glowing glass filaments 

  Illumination by halogen light 

3.3  Technical Data 

3.3.1  Capacity 

Depending on the size up to 6 chickens per spit. 

3.3.2  Dimensions [mm] 

Model 

W x H x D 

Number of Spits: 

FF - 22: 

1120 x 1000 x 675 

FF - 24: 

1120 x 1515 x 675 

FF - 26: 

1120 x 2030 x 675 

FF - 28: 

1120 x 2545 x 675 

FF - 32: 

1450 x 1000 x 675 

FF - 34: 

1450 x 1515 x 675 

FF - 36: 

1450 x 2030 x 675 

FF - 38: 

1450 x 2545 x 675 

FF - 42: 

1780 x 1000 x 675 

FF - 44: 

1780 x 1515 x 675 

FF - 46: 

1780 x 2030 x 675 

FF - 48: 

1780 x 2545 x 675 

3.3.3  Weight [kg] 

Model 

Net weight: 

FF - 22: 

ca 210kg 

FF - 24: 

ca 290kg 

FF - 26: 

ca 340kg 

FF - 28: 

ca 410kg 

FF - 32: 

ca 280kg 

FF - 34: 

ca 380kg 

FF - 36: 

ca 440kg 

FF - 38: 

ca 510kg 

FF - 42: 

ca 380kg 

FF - 44: 

ca 445kg 

FF - 46: 

ca 495kg 

FF - 48: 

ca 565kg 

Содержание FF Series

Страница 1: ...User Manual Wall of Flame FF Series...

Страница 2: ......

Страница 3: ...ata 8 4 Initial Installation Procedure 14 4 1 Unpacking 14 4 2 Installation 14 4 3 Electrical connection 15 4 4 Gas connection 15 4 5 Re adjustment 16 4 6 Waste Water Connection 17 4 7 Preparation of...

Страница 4: ...following That they know about the basic safety instructions and do know the regulations how to prevent possible accidents That they have read the safety chapter and warnings in this operation manual...

Страница 5: ...on regular maintenance of any parts being subject to wear and tear In case of nonprofessional service In case of any force majeure 2 3 Explanation of Symbols and notes for the user Within this operati...

Страница 6: ...are only allowed to operate the unit under supervision of a trained and experienced person 2 5 4 Operating the controls Only trained personnel is allowed to operate the controls 2 5 5 Safety check du...

Страница 7: ...the manufacturer Never weld on load bearing parts of construction All reconstructions do require a written permission of the manufacturer Improper parts have to be changed immediately Only use origin...

Страница 8: ...al effect by glowing glass filaments Illumination by halogen light 3 3 Technical Data 3 3 1 Capacity Depending on the size up to 6 chickens per spit 3 3 2 Dimensions mm Model W x H x D Number of Spits...

Страница 9: ...able FF 28 LPG 50mbar 4 130 80 screwed tightly open 20 screwed tightly FF 28 LPG 30mbar 4 140 90 screwed tightly open 20 screwed tightly FF 28 Natural gas H 4 240 50 adjustable open 35 adjustable FF 2...

Страница 10: ...F 44 Natural gas H 4 240 50 adjustable open 35 adjustable FF 44 Natural gas L 4 260 50 adjustable open 35 adjustable FF 44 Natural gas E 4 240 50 adjustable open 35 adjustable FF 46 LPG 50mbar 6 130 8...

Страница 11: ...s L 30 9 12 3 69 FF 26 Natural gas E 20mbar 30 8 48 3 17 FF 26 Natural gas E 25mbar 27 7 3 17 FF 28 LPG 40 13 87 3 15 FF 28 Natural gas H 40 11 31 4 23 FF 28 Natural gas L 40 12 16 4 93 FF 28 Natural...

Страница 12: ...ural gas L 60 18 24 7 38 FF 46 Natural gas E 20mbar 60 16 96 6 34 FF 46 Natural gas E 25mbar 54 14 6 34 FF 48 LPG 80 27 74 6 3 FF 48 Natural gas H 80 22 62 8 46 FF 48 Natural gas L 80 24 32 9 86 FF 48...

Страница 13: ...Power kW Electrical connection V N Hz 0085 Differing from a m indications the type plate will be executed suitable for the following countries Netherlands for natural gas L connection pressure 25 mba...

Страница 14: ...y that the surrounding area can be cleaned 4 2 2 Place of operation Attention The device must be placed on a level solid and fireproof surface in an well ventilated room under an on site extraction ho...

Страница 15: ...cal and technical data of your unit from the nameplate The unit is ready for plug in For power supply a shockproof socket is necessary Make sure the supply cable is protected separately with 16 Amps T...

Страница 16: ...2 control of type plate or pressure measurement 4 4 4 Control of function Set the unit into operation according to the manual Check the unit for gas leaks Check the correct adjustment of primary air a...

Страница 17: ...the ignition cable from all piezo ignitors Remove the front operation panel carefully after unscrewing it The minimum adjustment nozzle is to be find at the upper front side of the all gas valve Unsc...

Страница 18: ...taking up the grill products 2 Fat Drawer catches the meat juice and fat coming out of the grill product 3 Gear chain sets the spit in rotation 4 Spit support used as outer support of spit 5 Control k...

Страница 19: ...the key of the piezo igniter After the ignition still push the knob for approx 15 20 seconds For minimum adjustment you have to turn the knob counter clockwise Turn the knob on position 0 in order to...

Страница 20: ...ade steel machine working always keep the high grade steel surface clean watch out that there is always enough fresh air on the surface never contact the surface with rusty material never use bleachin...

Страница 21: ...ageous anti corrosive properties The corrosion resistance of the rustproof steel has a passive layer which can be formed on the surface by oxidation The oxygen in the air is enough to form a passive l...

Страница 22: ...f natural plastic or stainless steel bristles for mechanical cleaning Steel wool or brushes with unalloyed steel lead to external rust caused by abrasion Fresh rust spots can be removed with mild acti...

Страница 23: ...nd the bottom plate Remove the ignition cable from the piezo igniter You can remove and replace the piezo igniter by loosening the fixing nut from the front panel The re installation is to be made in...

Страница 24: ...rsed sequence 6 5 7 Motor Remove the lower fat drawer and the bottom plate Loosen the 2 screws from the protection plate above the motor and remove it Unplug the motor Loosen the chain tension union f...

Страница 25: ...its Spit does not rotate motor is not switched on Protective circuit breaker has re leased motor is defect Switch on the motor Push the protective circuit breaker gear 1 x Call the service Illuminatio...

Страница 26: ...r piezo ignitor 1 3m 180710 1 ignition cable for piezo ignitor 1 75m 180711 1 FF26 Description Part No Amount scale light motor 360203 2 scale gas valve 360215 3 drive shaft 180596 1 burner 180590 3 c...

Страница 27: ...ng drive shaft 380601 4 ignition cable for piezo ignitor 1 3m 180710 1 ignition cable for piezo ignitor 1 75m 180711 1 ignition cable for piezo ignitor 2 2m 180712 1 ignition cable for piezo ignitor 2...

Страница 28: ...1 3m 180710 2 ignition cable for piezo ignitor 1 75m 180711 2 ignition cable for piezo ignitor 2 2m 180712 2 FF38 Description Part No Amount scale light motor 360203 2 scale gas valve 360215 8 drive s...

Страница 29: ...1 3m 180710 2 ignition cable for piezo ignitor 1 75m 180711 2 FF46 Description Part No Amount scale light motor 360203 2 scale gas valve 360215 6 drive shaft 180597 1 burner left 180590 6 cast iron fi...

Страница 30: ...m 352327 2 temperature probe M8 850mm 352328 2 temperature probe extension M8 M10 600mm 352329 6 switch element for push button 380242 1 push button 380244 1 ignition transformer 380260 1 pilot flame...

Страница 31: ...Maintenance 31 printed 06 2020 Subject to change FFUserManual docx 6 9 Declaration of Conformity...

Отзывы: