Operation
Page 19
printed: 06/2020 Subject to change!
:FFUserManual.docx
5.2 Operation / handling
Please observe the following check list for starting the operation of the unit.
Attention!
The ignition process takes place principally from downwards to upwards.
•
For igniting you have to turn the knob one eighth (1/8) rotation to the left
towards the ignition symbol.
•
Then push the knob up to the stop so that the gas flows out.
•
For ignition push the key of the piezo igniter.
•
After the ignition still push the knob for approx. 15 – 20 seconds.
•
For minimum adjustment, you have to turn the knob counter-clockwise.
•
Turn the knob on position 0 in order to switch off the main burner.
When you adjust the spit distances please observe that the spits are moved parallel to
the burner in order to achieve an even product result and in order not to overstrain the
spit gear motor.