Maintenance
Page 23
printed: 06/2020 Subject to change!
:FFUserManual.docx
6.3.2 Burner reaction
Checking of the burner reaction has to be made by sight and function control. The flames have to
burn stable and not yellow, not to lift up or flash back.
6.3.3 Heat Load and Test for leakages
For this check the right nozzles and the correct connection pressure. Further make a leakage test.
6.4 Maintenance of the bearing and the drive chain
Please check at least quarterly, more often if necessary, the fat content of the bearing and the
chain. If this is not the case, you have to renew the fat, so it can work perfectly. Please use for the
new fat only heat-resistant fat. If you disregard it, the bearing could take damage. If this is the
case, the spit rotation will not work.
6.5 Changing part
Every time you replace any parts at the unit you have to close the main gas supply and to unplug
the unit. After you have finished the work you have to control the function (acc. to section 1.5.3)!
6.5.1 Piezo igniter
•
Remove the lower fat drawer and the bottom plate.
•
Remove the ignition cable from the piezo igniter.
•
You can remove and replace the piezo igniter by loosening the fixing nut from the front panel.
The re-installation is to be made in reversed sequence.
6.5.2 Ignition plug
The ignition plug at the pilot flame burner can be replaced acc. to section 4.5.1.
6.5.3 Thermo element
•
Remove the lower fat drawer and the bottom plate.
•
Remove the corresponding side wall after you have unscrewed it.
•
Remove the thermo element from the pilot flame device (see 4.5.1)
•
Remove the thermo element union from the all gas valve.
The assembling is to be made in reversed sequence.
6.5.4 Pilot flame device
See section 4.5.1. The gas lead between the all gas valve and pilot flame device can be removed
by loosening of the unions of these both parts.
6.5.5 Burner
•
Remove the spits and the fat drawer in front of the burner which has to be replaced.
•
Close the main gas supply and unplug the unit.
Access from the front side of the unit:
•
Remove the spits and fat drawers
•
Remove the ribs as follows:
5. Push the rib upwards.
6. Push the lower rib to the rear.
7. Pull the rib downwards.
8. Remove the rib to the front.
Access from the rear side of the unit
•
Remove the rear wall after un-
screwing it.
Содержание FF Series
Страница 1: ...User Manual Wall of Flame FF Series...
Страница 2: ......
Страница 31: ...Maintenance 31 printed 06 2020 Subject to change FFUserManual docx 6 9 Declaration of Conformity...