5
I. Product Description, Specifications and Dimensional Data
Alpine Series boilers are condensing high efficiency gas-
fired direct vent hot water boilers designed for use in forced
hot water space or space heating with indirect domestic hot
water heating systems, where supply water temperature
does not exceed 210°F. These boilers have special coil
type stainless steel heat exchangers, constructed, tested and
stamped per Section IV ‘Heating Boilers’ of ASME Boiler
and Pressure Vessel Code, which provide a maximum heat
transfer and simultaneous protection against flue gas product
corrosion. These boilers are not designed for use in gravity
hot water space heating systems or systems containing
significant amount of dissolved oxygen (swimming pool
water heating, direct domestic hot water heating, etc.).
Table 2: Dimensions (See Figures 1, 2, and 3)
Table 1: Specifications
Specification
Boiler Model
ALP399C
ALP500C
ALP600C
ALP700C
ALP800C
Altitude (ft. above sea level)
1
0-10,100
0-10,100
2
0-10,100
0-10,100
3
0-6,000
4
Fuel
Shipped for Natural Gas, Field
Converted for LP Gas
Shipped for Natural Gas or Shipped for LP Gas
(no Field Conversion)
Max. Allowable Water Temperature (°F)
210
210
210
210
210
Max. Allowable Working Pressure (psi)
160
160
160
160
160
Factory Supplied Safety Relief Valve (psi)*
50
50
60
60
60
Boiler Water Volume (gal.)
3.4
4.3
5.4
5.4
6.2
Heat Transfer Area (sq. ft.)
41.8
58.1
76.2
76.2
87.0
Approx. Shipping Weight (lb.)
316
368
458
458
500
* Optional 80 psi and 100 psi safety relief valves are available for all models.
1
Follow Instructions for High Altitude Installations above 2000 ft. (see Appendix A)
2
ALP500C LP cannot be installed above 6,000 ft.
3
ALP700C LP cannot be installed above 7,800 ft.
4
ALP800C natural gas cannot be installed above 6,000 ft. ALP800C LP can be installed up to 10,100 ft.
Dimension
Boiler Model
ALP399C
ALP500C
ALP600C
ALP700C
ALP800C
A - Inch
(mm)
31-3/16
(792)
46-1/2
(1181)
49-1/2
(1258)
49-1/2
(1258)
53-5/16
(1258)
B - Inch
(mm)
5-1/2
(140)
N/A
N/A
N/A
N/A
C - Inch
(mm)
12-3/8
(314)
21-5/16
(541)
23-1/4
(591)
23-1/4
(591)
23-7/16
(596)
D - Inch
(mm)
23
(584)
34-13/16
(884)
38-1/16
(967)
38-1/16
(967)
41-3/16
(1046)
E - Inch
(mm)
15-1/8
(384)
28-5/16
(719)
30-7/8
(784)
30-7/8
(784)
32-9/16
(827)
Gas Inlet G - Inch
3/4 (FPT)
1 (FPT)
Return H - Inch
1-1/2 FPT
2 MPT
Supply J - Inch
1-1/2 FPT
2 MPT
PP Condensate Drain K - Inch
3/4 PVC Compression Coupling
PVC Combustion Air Connector - Inch
4
CPVC/PP/SS Vent Connector - Inch
(mm)
4
(100)
6
(150)
Содержание Alpine ALP500C
Страница 14: ...14 III Pre Installation and Boiler Mounting H Boiler Stacking continued Figure 5 Boiler Stacking ...
Страница 48: ...48 VI Water Piping and Trim continued Figure 28 Near Boiler Piping Heating Only ...
Страница 60: ...60 Figure 37 PCB Locations for Field Wiring Figure 38 120 VAC Field Wiring VIII Electrical continued ...
Страница 62: ...62 Figure 40 Ladder Diagram VIII Electrical continued ...
Страница 63: ...63 VIII Electrical continued 2 Figure 41 Wiring Connections Diagram ...
Страница 67: ...67 VIII Electrical continued Figure 45 Boiler to Boiler Communication with Zone Control Circulator Panel ...
Страница 72: ...72 IX System Start up continued Figure 48 Operating Instructions ...
Страница 124: ...124 XIII Repair Parts continued ...
Страница 126: ...126 XIII Repair Parts continued ALP600C ALP700C and ALP800C ALP800C shown ...
Страница 130: ...130 XIII Repair Parts continued ...
Страница 133: ...133 XIII Repair Parts continued 10A 10B 10C 10D 10G ...
Страница 143: ...143 ...
Страница 144: ...144 U S Boiler Company Inc P O Box 3020 Lancaster PA 17604 1 888 432 8887 www usboiler net ...