6.7 Language

 

Select English, Japanese, Spanish.

 

Scroll to select "Language”, then press "OK.” Then scroll through to select the desired 
language.

 

 

6.8 Advanced Setup

 

6.8.1 Unknown Format

 

This function only works with “6.2 Copy Area >> System and Files.”

 

Scroll to select "Unknown Format”, then press "OK”. 

 

Unknown format includes all forms of modified and proprietary data and partitions.

 

❶ Copy Unknown

 

Copy unknown format(s).

 

Scroll to select "Unknown Format >> Copy Unknown”, then press "OK" to save this setting.

 

❷ Skip Unknown

 

Skip unknown format(s).

 

Scroll to select "Unknown Format >> Skip Unknown”, then press "OK" to save this setting.

 

 

6.8.2 Erase Master

 

This function allows user to enable or disable the source port for sanitization.

 

Scroll to select "Erase Master”, then press "OK.” Then scroll through to select one of two 
settings.

 

 

❶ Disabled

 

Devices connected to source port cannot be erased.

 

Scroll to select "Erase Master >> Disabled”, then press "OK" to save this setting.

 

 

❷ Enabled

 

Devices connected to source port can be erased.

 

Scroll to select "Erase Master >> Enabled”, then press "OK" to save this setting.

 

 

6.8.3 Erase Pattern

 

Scroll to select "Erase Pattern”, then press "OK”. Then scroll through to select one of two 
settings.

 

 

❶ One Byte

 

Random character written per byte.

 

Содержание MT Series

Страница 1: ...MT MTC Series IDE SATA Duplicator and Sanitizer User Manual v A 04...

Страница 2: ...ty 3 Piracy Statement 3 Before You Start 4 Notice Symbols 4 Functions Table 5 Hardware Overview 9 Functions 12 1 Copy 12 2 Compare 13 3 Copy Compare 13 4 Erase 13 5 Utility 15 7 Log Manager 26 Real ti...

Страница 3: ...ducts software program and or hardware issues can cause loss of data defective formatting or unreliable data loading U Reach will make efforts to resolve or repair any issues recognized by customer ei...

Страница 4: ...r cord for 2 minutes for discharge Use product only in a clean dry dust free and ventilated area Liquids or foreign debris can severely damage your duplicator It is typical for the machine to heat up...

Страница 5: ...4 3 DoD Erase Erases device s complying with DoD 5220 22 M Standards 4 4 DoD EraseComp Erases device s complying with DoD 5220 22 M Standards and verifies complete erasure 4 5 7 Pass Erase Erases dev...

Страница 6: ...and skips empty space Only supports standard formats ALL Partitions Copies all partitions and data unallocated partitions not included Whole HDD Copies all source data bit by bit Percentage Sets perc...

Страница 7: ...Lock Key After keys are locked only OK ESC buttons will function System reboot is required 6 8 7 HPA Copy Mode Do Not Copy HPA Keep Target HPA Does not copy HPA data but keeps target device s original...

Страница 8: ...ice Signature After Copy No Yes Do not copy the disk signature onto target devices 6 9 Restore Defaults Reinstates manufacturer settings 7 Log Manager 7 1 Out Today Report Outputs today s log data 7 2...

Страница 9: ...re Overview Front View Back View USB Port for PC LINK Power Input USB port for Log Report Outputs and Firmware Updates LCD Display Control Buttons Grounding Port Daisy Chain Output Port Daisy Chain In...

Страница 10: ...10 LED Indicator LCD Configuration Yellow Powered Green Pass Red Fail...

Страница 11: ...TC Series Front View Back View Caution If the connection is successful the connected units will display Networked Duplicator on the LCD screen and will disable the control buttons Daisy Chain Cable Da...

Страница 12: ...s capacity must be equal to or larger than the source device capacity Note The number of working connected targets will be displayed on LCD Press OK to start Note Press together for 5 seconds to stop...

Страница 13: ...e Scroll to select 4 Erase then press OK to view these erase modes Caution User is responsible for verification of targets quality Testing a few completed targets in a mass production environment for...

Страница 14: ...e device s 7 times complying with DoD 5220 22 M ECE Standards Scroll to select 7 Pass Erase then press OK to start the erasing process 4 6 Secure Erase This function erases the non loadable areas comp...

Страница 15: ...Prepare a USB drive for update Connect a USB drive to a PC Download the latest firmware provided by our technical support unzip the BIOS firmware then save it to the root directory in the USB drive S...

Страница 16: ...press OK to initiate process Then scroll through to view connected device s by port order 5 5 Strict Verify HDD This function scans device for any bad sectors by reading and writing two times Scroll t...

Страница 17: ...methods Selecting the Proper Copy Modes Example There are two defined partitions in a 500GB device The charts below illustrate what portion would be duplicated Copy and Compare Preparations Please con...

Страница 18: ...method Allows user to copy source device s System and Files instead of the entire device The system will analyze the source device and identify the data area to copy If the source device s data is wi...

Страница 19: ...press OK to save the copy method Copies the whole source device irrespective of content format partition or empty space This mode does not analyze the data Percentage Select percentage of source capa...

Страница 20: ...vice capacity prior to copying 2 Deep Analysis is recommended for use with 8 1 Copy SSD to Image Caution 1 Use a clean source device to make the analyzed data capacity shorter Clean Source Device mean...

Страница 21: ...speed during Copy Compare Erase Scroll to select Minimum Speed then press OK to set desired minimum threshold speed The system will fail if any device does not achieve minimum speed Users can choose D...

Страница 22: ...own format s Scroll to select Unknown Format Skip Unknown then press OK to save this setting 6 8 2 Erase Master This function allows user to enable or disable the source port for sanitization Scroll t...

Страница 23: ...default is 30 seconds 6 8 6 Lock Key This function allows users to enable or disable the 4 control panel buttons Scroll to select Lock Key then press OK to access available settings Disabled Scroll to...

Страница 24: ...at Erase Sets to clear HPA setting during erase Scroll to select Clear HPA at Erase then press OK to save this setting Clear HPA Setting Clears HPA setting and data during erase Scroll to select Clea...

Страница 25: ...the size of the data transfer between the duplicator and the HDD The setting value is form 512Byte to 16Mbyte 6 8 13 Delete Device Signature After Copy Set at Yes means do not copy the disk signature...

Страница 26: ...n process By displaying detailed information for each port this tool helps to identify the slowest writing device that in turn keeps the operation running efficiently Note 1 The USB must be FAT16 FAT3...

Страница 27: ...asks press ESC key the LV07H status will return to STANDBY Step 1 Click Generate Log Report in the field of LV07H screen Log Data Step 2 Select Date Range After entering Open Report select the date ra...

Страница 28: ...le Step 5 Save Log to the Specific Location Specify a name and location to save the log Note If there is no record saved on the selected date or record has been wiped out the program would show No mat...

Страница 29: ...sfully creating and saving the log the report will be in the folder in which it was saved Caution 30 000 logs can be saved at one time One device record is equal to one recorded log E g duplication fr...

Страница 30: ...ouble clicking on software icon LV07H Step 5 When the below screen is shown the duplicator has linked to the computer successfully and is ready to use real time monitoring function Step 6 If the scree...

Страница 31: ...the program will display all related device information It captures detailed information from each device via PC Monitoring e g device model S N copy speed etc It also records all operational progres...

Страница 32: ...ows user to access several submenus Scroll to select Advanced Function then press OK access submenus Default password 123456 7 4 1 Clear All Log Clear all log records Scroll to select Clear All logs t...

Страница 33: ...k at text File Creates a watermark on the log report The log report can be checked by software iSecuLog exe to prevent modifying Specifications are subject to change without notice Note If you want to...

Отзывы: