LOADING/CHANGING THE BATTERY

1.  Using a flathead screwdriver, rotate the battery  

door lock to the unlocked position and  

open the battery door.

2.  Connect one 9V battery to the  

connector block. Fit the battery  

into the compartment.  

(See Figure 1)

3.  Close the battery door. Turn the  

battery lock to the locked position.

SELECTING CELSIUS OR FAHRENHEIT

To set the temperature scale, pull the trigger, then press 

the 

SET button three times. Press the buttons above the 

up and down arrows to toggle between "C" and "F." Wait 

five seconds for the setting to save and exit. 

SETTING THE LASER LOCK

To turn the laser on and off, pull the trigger, then press 

the 

SET button four times. Press the buttons above the up 

and down arrows to toggle between ON and OFF. Wait 

five seconds for the setting to save and exit. 

  

ASSEMBLY

OPERATION

SCANNING OBJECT TEMPERATURE

1.  Pull and hold the trigger for at least two seconds 

and scan the surface temperature of an object. A 

laser pointer is used for aiming on the area being 

scanned.

NOTE: The object should be larger than the 
spot being scanned. If not, readings will be 
affected. See Figure 2 for necessary object size.

2.  As you continue to hold the trigger, the  

 

 icon is displayed along with the 

primary measurement (surface 

temperature) and secondary 

measurement (maximum, minimum, 

average or differential temperature) 

readings. 

3.  Release the trigger. HOLD is displayed 

until the screen shuts off in about ten 

seconds.

NOTE: A quick change in temperature (>10°F) 
affects the meter’s readings. Allow the meter to 
reach ambient temperature before use (5 to 30 
minutes, depending on temperature change).

SETTING THE TRIGGER LOCK

1.  To turn the trigger lock on and off, pull the trigger, then 

press the 

SET button five times. Press the buttons above 

the up and down arrows to toggle between ON and 

OFF. Wait five seconds for the setting to save and exit.

TEMPERATURE ALARM

1.  Press the 

ALARM button to turn on the 

alarm function.

2.  The bell icon is displayed. If the 

temperature reading is outside the preset 
range, the temperature reading will flash 
and an alarm will sound.

SETTING PRESET RANGE FOR THE ALARM

1.  To set the alarm range, pull and hold the 

trigger, then press the 

SET button. Repeat to 

toggle between LO and HI settings.

2.  Press the up or down arrow soft keys to 

toggle between temperatures. Wait five 

seconds for the ranges to save and exit.

LOW BATTERY

When the low battery icon is displayed, change the battery.

WARNING! Always remove battery before 
changing or removing accessories. Only use 
accessories specifically recommended for this 
tool. Others may be hazardous.

Mode Description

MAX

Displays maximum temperature measured during a 

continuous reading.

MIN

Displays minimum temperature measured during a 

continuous reading.

AVG

Displays average temperature of last 20 measurements 

during a continuous reading.

DIF

Displays the difference between MAX and MIN during a 

continuous reading.

DISTANCE TO SPOT – 10:1

——  Center of Spot
– – – Laser pointer (approx. 3/4" above center of spot)
      Spot size at distance indicated

At 5' away, 

spot is 6" 

in diameter

At 3' away, 

spot is 3.6" 

in diameter

At 1' away, 

spot is 1½"

in diameter

MAX

0

516

3

81

2

MAX

0

516

3

81

2

HOLD

Figure 1

MAX

9

216

HI

1

32

LO

MAX

0

516

3

81

2

MAX

0

516

3

81

2

Figure 2

Содержание H-5802

Страница 1: ...nder the influence of alcohol or medication A moment of inattention may result in serious personal injury Do not overreach Keep proper footing and balance at all times This enables better control in u...

Страница 2: ...F 4 F 0 2 2 F 0 to 32 F 5 F 32 to 752 F 4 F or 2 of reading whichever is greater Assume ambient operating temperature of 70 to 77 F Minimum Measuring Distance 2 122 F 4 122 F Temperature Display Resol...

Страница 3: ...w the meter to reach ambient temperature before use 5 to 30 minutes depending on temperature change SETTING THE TRIGGER LOCK 1 To turn the trigger lock on and off pull the trigger then press the SET b...

Страница 4: ...th a cotton swab moistened with water 3 Using a second cotton swab dry completely WARNING To reduce the risk of personal injury and damage never immerse your tool in liquid or allow a liquid to flow i...

Страница 5: ...atenci n podr a provocar lesiones personales graves No intente hacer m s de lo que sus posibilidades le permiten Establezca y mantenga un anclaje y equilibrio adecuados en todo momento Esto permite u...

Страница 6: ...C 0 a 32 F 5 F 0 a 400 C 15 6 C 32 a 752 F 4 F o 2 de la lectura lo que sea mayor Supone que la temperatura ambiente de funcionamiento es de 21 1 a 25 C 70 a 77 F Distancia Medible M nima 5 cm 50 C 10...

Страница 7: ...es de usarlo entre 5 y 30 minutos dependiendo del cambio de temperatura CONFIGURAR EL CIERRE DEL GATILLO 1 Para activar y desactivar el cierre del l ser jale del gatillo y presione el bot n SET cinco...

Страница 8: ...god n empapado en agua 3 Con un segundo hisopo de algod n seque completamente ADVERTENCIA Para reducir el riesgo de lesiones personales y da os nunca sumerja la herramienta en l quido ni permita que e...

Страница 9: ...tilisez le pistolet infrarouge N utilisez pas le pistolet quand vous tes fatigu ou sous l influence d alcool ou de m dicaments Un moment d inattention peut entra ner des blessures corporelles graves N...

Страница 10: ...C 0 32 F 5 F 0 400 C 15 6 C 32 752 F 4 F ou 2 de la valeur observ e selon la valeur la plus lev e Avec une temp rature ambiante de fonctionnement de 21 1 25 C 70 77 F Distance de mesure minimale 5 cm...

Страница 11: ...ion du changement de temp rature VERROUILLAGE DE LA D TENTE Pour verrouiller ou d verrouiller la d tente maintenez la d tente enfonc e puis appuyez sur la touche SET cinq reprises Appuyez sur les touc...

Страница 12: ...i me coton tige s chez compl tement AVERTISSEMENT Pour r duire le risque de blessures et de dommages n immergez jamais l outil dans un liquide et vitez que du liquide s introduise l int rieur NETTOYAG...

Отзывы: