manualshive.com logo in svg
background image

PAGE 2 OF 12 

0516 IH-5802

DIAGRAM

#

DESCRIPTION

1

Laser Window

2

Trigger

3

Display

4

Mode/Set/Alarm Buttons 

5

Battery Door Lock

6

Battery Door

7

Battery Indicator

8

Hold Indicator

9

Laser Active Indicator

10

Trigger Lock Indicator

11

Alarm Indicator

12

Celsius or Fahrenheit Indicator

13

Primary Measurement

14

Secondary Measurement

15

Mode Indicator

SPECIFICATIONS

Laser Type

Class II

Max Power

<1mW

Wavelength

630-670 nm

IR Temperature Range

-22° to 752°F

IR Accuracy

-22° to 0°F: ± 4°F + 0.2°/2°F

0° to 32°F: ± 5°F

32° to 752°F ± 4°F or 2% of reading, whichever is greater.

Assume ambient operating temperature of 70° to 77°F

Minimum Measuring Distance

2" < 122°F; 4" > 122°F

Temperature Display Resolution

0.1°F in Primary and Secondary

Emmissivity

0.95

Response Time

<500 msec

Spectral Response

8 to 14µm

Distance to Spot

10 to 1

Drop

2 meters

Repeatability

±0.8% or ±2°F (whichever is greater)

Operating Temperature

32° to 122°F

Storage Temperature

-4° to 140°F without battery

Relative Humidity

10 to 85% at 77°F, decreasing linearly to 10 to 45% at 122°F

Voltage

9 DC (one 9V battery)

Battery Life

>12 hours with all functions

2

5

1

3

6

4

7

8

10

12

11

9

HOLD

MAX

MIN

AVG

OFF

13

14

15

Содержание H-5802

Страница 1: ...nder the influence of alcohol or medication A moment of inattention may result in serious personal injury Do not overreach Keep proper footing and balance at all times This enables better control in u...

Страница 2: ...F 4 F 0 2 2 F 0 to 32 F 5 F 32 to 752 F 4 F or 2 of reading whichever is greater Assume ambient operating temperature of 70 to 77 F Minimum Measuring Distance 2 122 F 4 122 F Temperature Display Resol...

Страница 3: ...w the meter to reach ambient temperature before use 5 to 30 minutes depending on temperature change SETTING THE TRIGGER LOCK 1 To turn the trigger lock on and off pull the trigger then press the SET b...

Страница 4: ...th a cotton swab moistened with water 3 Using a second cotton swab dry completely WARNING To reduce the risk of personal injury and damage never immerse your tool in liquid or allow a liquid to flow i...

Страница 5: ...atenci n podr a provocar lesiones personales graves No intente hacer m s de lo que sus posibilidades le permiten Establezca y mantenga un anclaje y equilibrio adecuados en todo momento Esto permite u...

Страница 6: ...C 0 a 32 F 5 F 0 a 400 C 15 6 C 32 a 752 F 4 F o 2 de la lectura lo que sea mayor Supone que la temperatura ambiente de funcionamiento es de 21 1 a 25 C 70 a 77 F Distancia Medible M nima 5 cm 50 C 10...

Страница 7: ...es de usarlo entre 5 y 30 minutos dependiendo del cambio de temperatura CONFIGURAR EL CIERRE DEL GATILLO 1 Para activar y desactivar el cierre del l ser jale del gatillo y presione el bot n SET cinco...

Страница 8: ...god n empapado en agua 3 Con un segundo hisopo de algod n seque completamente ADVERTENCIA Para reducir el riesgo de lesiones personales y da os nunca sumerja la herramienta en l quido ni permita que e...

Страница 9: ...tilisez le pistolet infrarouge N utilisez pas le pistolet quand vous tes fatigu ou sous l influence d alcool ou de m dicaments Un moment d inattention peut entra ner des blessures corporelles graves N...

Страница 10: ...C 0 32 F 5 F 0 400 C 15 6 C 32 752 F 4 F ou 2 de la valeur observ e selon la valeur la plus lev e Avec une temp rature ambiante de fonctionnement de 21 1 25 C 70 77 F Distance de mesure minimale 5 cm...

Страница 11: ...ion du changement de temp rature VERROUILLAGE DE LA D TENTE Pour verrouiller ou d verrouiller la d tente maintenez la d tente enfonc e puis appuyez sur la touche SET cinq reprises Appuyez sur les touc...

Страница 12: ...i me coton tige s chez compl tement AVERTISSEMENT Pour r duire le risque de blessures et de dommages n immergez jamais l outil dans un liquide et vitez que du liquide s introduise l int rieur NETTOYAG...

Отзывы: