SPECIFICATIONS

Laser Type

Class II

Max Power

<1mW

Wavelength

630-670 nm

IR Temperature Range

-22° to 752°F

IR Accuracy

-22° to 0°F: ± 4°F + 0.2°/2°F

0° to 32°F: ± 5°F

32° to 752°F ± 4°F or 2% of reading, whichever is greater.

Assume ambient operating temperature of 70° to 77°F

Minimum Measuring Distance

2" < 122°F; 4" > 122°F

Temperature Display Resolution

0.1°F in Primary and Secondary

Emmissivity

0.95

Response Time

<500 msec

Spectral Response

8 to 14µm

Distance to Spot

10 to 1

Drop

2 meters

Repeatability

±0.8% or ±2°F (whichever is greater)

Operating Temperature

32° to 122°F

Storage Temperature

-4° to 140°F without battery

Relative Humidity

10 to 85% at 77°F, decreasing linearly to 10 to 45% at 122°F

Voltage

9 DC (one 9V battery)

Battery Life

>12 hours with all functions

2

5

1

3

6

4

7

8

10

12

11

9

HOLD

MAX

MIN

AVG

OFF

13

14

15

Содержание H-5802

Страница 1: ...nder the influence of alcohol or medication A moment of inattention may result in serious personal injury Do not overreach Keep proper footing and balance at all times This enables better control in u...

Страница 2: ...F 4 F 0 2 2 F 0 to 32 F 5 F 32 to 752 F 4 F or 2 of reading whichever is greater Assume ambient operating temperature of 70 to 77 F Minimum Measuring Distance 2 122 F 4 122 F Temperature Display Resol...

Страница 3: ...w the meter to reach ambient temperature before use 5 to 30 minutes depending on temperature change SETTING THE TRIGGER LOCK 1 To turn the trigger lock on and off pull the trigger then press the SET b...

Страница 4: ...th a cotton swab moistened with water 3 Using a second cotton swab dry completely WARNING To reduce the risk of personal injury and damage never immerse your tool in liquid or allow a liquid to flow i...

Страница 5: ...atenci n podr a provocar lesiones personales graves No intente hacer m s de lo que sus posibilidades le permiten Establezca y mantenga un anclaje y equilibrio adecuados en todo momento Esto permite u...

Страница 6: ...C 0 a 32 F 5 F 0 a 400 C 15 6 C 32 a 752 F 4 F o 2 de la lectura lo que sea mayor Supone que la temperatura ambiente de funcionamiento es de 21 1 a 25 C 70 a 77 F Distancia Medible M nima 5 cm 50 C 10...

Страница 7: ...es de usarlo entre 5 y 30 minutos dependiendo del cambio de temperatura CONFIGURAR EL CIERRE DEL GATILLO 1 Para activar y desactivar el cierre del l ser jale del gatillo y presione el bot n SET cinco...

Страница 8: ...god n empapado en agua 3 Con un segundo hisopo de algod n seque completamente ADVERTENCIA Para reducir el riesgo de lesiones personales y da os nunca sumerja la herramienta en l quido ni permita que e...

Страница 9: ...tilisez le pistolet infrarouge N utilisez pas le pistolet quand vous tes fatigu ou sous l influence d alcool ou de m dicaments Un moment d inattention peut entra ner des blessures corporelles graves N...

Страница 10: ...C 0 32 F 5 F 0 400 C 15 6 C 32 752 F 4 F ou 2 de la valeur observ e selon la valeur la plus lev e Avec une temp rature ambiante de fonctionnement de 21 1 25 C 70 77 F Distance de mesure minimale 5 cm...

Страница 11: ...ion du changement de temp rature VERROUILLAGE DE LA D TENTE Pour verrouiller ou d verrouiller la d tente maintenez la d tente enfonc e puis appuyez sur la touche SET cinq reprises Appuyez sur les touc...

Страница 12: ...i me coton tige s chez compl tement AVERTISSEMENT Pour r duire le risque de blessures et de dommages n immergez jamais l outil dans un liquide et vitez que du liquide s introduise l int rieur NETTOYAG...

Отзывы: