PAGE 8 OF 8
HEATING ELEMENT REPLACEMENT
The heating element expands and contracts during
each sealing cycle and will eventually break over
time. Replace using only Uline heating elements.
Make sure that the machine is turned off
and the power cord is secured before
working on the machine.
Any attempt to use elements designed
for use on another machine or in another
application may not work properly and
may cause damage and/or create a
dangerous situation. Use of non Uline parts
will void all warranties.
Loosen the two clamp mounting screws and
rotate the roller knobs to rewind the Teflon
®
onto the roller to expose the heating element.
(See Figure 9)
Remove the heating element retaining nuts at
each end of the element (keep for reuse).
Remove the old heating element and
discard.
Inspect the insulator on the lower jaw for signs
of cracks, pits, burn marks, etc.
If the insulation material is worn replace it
before installing the new heating element.
Remove the old insulator when necessary,
clean the area, apply a smooth coating of RTV
adhesive, install the replacement insulation
and allow it to dry for several hours before
installing the new heating element.
NOTE: The heating element has a top
and a bottom. See Figure 9 for proper
positioning and installation.
NOTE: The seal jaw assembly is spring-
loaded on left end, fixed on right end.
.
2.
.
.
5.
Place the left end of the new heating element
over the threaded post at the left end of the
jaw assembly.
Compress the left end of the jaw (spring-
loaded) and place the right end of the
heating element over the fixed threaded post
on the right end.
Make sure that the heating element is
positioned correctly, is not twisted and lays
flat against the lower jaw.
Reinstall the retainer nuts no more than finger-
tight.
Reinstall the lower Teflon
®
cover.
6.
7.
8.
9.
0.
HEATING ELEMENT INSTALLATION
TOP
SIDE VIEW - HEATING ELEMENT
RETAINER NUT
SPRING LOADED TERMINATION
RETAINER NUT
BROKEN ELEMENT
BARRIER STRIP
NEW ELEMENT
REMOVE OR ROLL UP
LOWER TEFLON ASSY.
PRIOR TO STARTING
1
2
3
USE A SMALL SCREW DRIVER
TO COMPRESS THE TENSION
SPRING DURING INSTALLATION
NOTE:
REPLACE TEFLON
COVER BEFORE USE
Figure 9: Replacing heating element
1-800-295-5510
uline.com