12. ACCESSORIES 

 

ADI Part 
Number 

 

Item Description 

430011 

Fuse 100A, ANN-250 

430052 

Fuse 150A, ANN-150 

430054 

Fuse 350A, ANN-350 

430010 

Fuse 200A, ANN-200 

431021 

Fuse holder with cover 

611096 

Inverter cable assembly 10ft, 4-gauge, 200A fuse and fuse holder 

611089 

Inverter cable assembly 15ft, 4-gauge, 200A fuse and fuse holder 

611103 

Inverter cable assembly 10ft, 6-gauge, 150A fuse and fuse holder 

611034 

Inverter cable assembly 15ft, 2-gauge, 250A fuse and fuse holder 

611022 

Inverter cable assembly 20ft, 2-gauge, 250A fuse and fuse holder 

611100 

Inverter cable assembly 20ft, 1/0-gauge, 350A fuse and fuse holder 

611348 

Remote lighted rocker switch kit with fuse and 14ft 18-gauge cable (dash mount) 

611522 

Remote switch panel kit with fuse and 14ft 18-gauge cable (electrical box mount) 

140004 

Battery box single group 31 

250018 Ventilation 

assembly 

(battery box) 42in long 

 

13. APPENDIX 

 

Battery Specifications Chart 

 

Group

Voltage

Capacity

Weight

Number

Volts DC

Amp-Hour

L

W

H

LBS

GC2

6

220

10 

3/8

3/16

10 

5/8

70

L16

6

350

11 

3/4

1/8

16 

3/4

125

27/31

12

95

13

13/16

7/16

70

4D

12

180

20 

3/4

3/4

9

 7/8

140

8D

12

225

20

 3/4

11 

1/8

9

 7/8

170

Dimensions in inches

 

 

Note:

 The use of deep-cycle batteries is strongly recommended on 

inverter applications; deep discharge cycles typical with inverter 

applications can shorten the life of other type of batteries. 

 
 

Sensata Technologies

 

Power Controls White Bear

 

4467 White Bear Pkwy, 

 

St. Paul, MN 55110-7626

 

Tel: 800-553-6418

 

Fax: 651-653-7600

 

[email protected]

 

http://dimensions.sensata.com  

Содержание 12WA7N

Страница 1: ...DC to AC Power Inverters Pure Sine Wave Output Owner s Manual MODELS 12WA7N 12WA10N...

Страница 2: ...put Wiring Diagram 10 Section 9 Overall Wiring Diagram 11 Physical Description 6 Section 7 Remote On Off Switch 9 Section 5 Inverter Mounting 8 Section 3 Nomenclature 5 Section 6 DC Wire Gauge Fusing...

Страница 3: ...put cables Warning Damage to the Power Inverter will occur if an external AC power source is applied to the inverter s AC hardwire output Warning Power Inverters contain a circuit breaker and capacito...

Страница 4: ...ge Any 120 VAC 60 Hz single phase product within the inverter s power rating INVERTER MODEL 12WA7N 12WA10 Dimensions LxWxH Inches Efficiency Input Current Amps DC Up to 70 Up to 100 Input Voltage Volt...

Страница 5: ...put Voltage 12 12VDC DI Dimensions Inverters Other Suffixes designates private label customer Pure Sine Signal Output Output Wattage 7 700 watt 10 1000 watt Chassis Designation WA N 3 Letter Suffix De...

Страница 6: ...ontrolled fan triggers only when necessary to cool down inside electronics 5 DC Field Wiring Compartment Provides access to the Positive Negative DC input lugs 6 DC input Openings Positive Negative Al...

Страница 7: ...er is operating from batteries in inverter mode 3 Low battery The Red LED indicates that the inverter is in a low battery voltage condition and will shutdown 4 Overload The Red LED indicates that the...

Страница 8: ...e The inverter mounting location should provide adequate ventilation and clearance to maintain room temperature during operation At least 1 2 inch of clearance is required on all sides 1 Locate a suit...

Страница 9: ...stranded copper cables in all cases 2 Use SGX cross linked polyurethane insulation type that complies with the high temperature insulation requirements 125 C of SAE J 1127 and vehicle manufacturer req...

Страница 10: ...the load side of the remote On Off switch to the cable lead extending from the inverter and the fused side to the positive post of the battery 6 Install the in line fuses removed in step 1 in the fus...

Страница 11: ...11 Form 122175 9 OVERALL WIRING DIAGRAM FIGURE 5 Typical AC DC wiring diagram Auxiliary battery configuration...

Страница 12: ...The green LED On will come on The AC power produced by the inverter comes from the energy stored in the battery bank through a sophisticated electronic inversion process A transformer a Metal Oxide Si...

Страница 13: ...t outlet make sure all breakers are reset If test light is on Check your AC connections and loads If test light is off Possible bad GFCI or transfer relay 1 3 Green LED External Power on Repeat 1 2 st...

Страница 14: ...d 14ft 18 gauge cable dash mount 611522 Remote switch panel kit with fuse and 14ft 18 gauge cable electrical box mount 140004 Battery box single group 31 250018 Ventilation assembly battery box 42in l...

Страница 15: ...f those goods subject to the qualifications indicated Sensata warrants to the original purchaser for use that the goods or any component thereof manufactured by Sensata will be free from defects in wo...

Страница 16: ...7 White Bear Parkway St Paul MN 55110 Phone 651 653 7000 800 553 6418 Fax 651 653 7600 888 439 3565 inverterinfo sensata com www dimensions sensata com Form 122175 03 25 2013 Sensata Technologies 2013...

Отзывы: