Limited Warranty Terms & Conditions 

 

SHIPPING TERMS: F.O.B. St. Paul Minnesota. Freight prepaid and billed, subject to prior credit approval. 
 
MINIMUM ORDER: $50.00 Net Price 
 
LOSS OR DAMAGE: Loss or damage in transit are the responsibility of the carrier. Any claim should be filed with the 
delivering transport company. Invoice, Bill of Lading and Delivery receipt with damage noted therein must accompany any 
claims for freight damage. Claims for shortage and lost shipments must be made in writing to Sensata Technologies, 
Power Controls White Bear, St. Paul, MN within 10 days of date of shipment. Claims not reported within this time frame 
will not be honored. 
 
PRICES: Prices are subject to change without notice. All orders are subject to acceptance at the factory. We reserve the 
right to invoice prices in effect at time of shipment. 
 
TERMS: Net 30 days with approved credit, credit card or C.O.D. 
 
RETURN GOODS POLICY: 

• No returned materials will be accepted without an accompanying Returned Materials Authorization Number (RMA) from 
the factory. 
• Credit will be issued for returned goods to the original purchaser within 60 days of purchase, provided the inverter is 
returned to Sensata unused and not mounted. The amount of credit will be issued at Sensata’s discretion based on the 
condition of the product. 
• Customer must be in good standing with Sensata Technologies. 
• Inverters that are discontinued, high-voltage (over 24vdc), special-order or used are excluded and will not be eligible for 
credit. Non-inverter items such as cable assemblies, fuses and fuse holders, will not be eligible for credit 
• Support components supplied by Sensata vendors will be covered under that manufacturer’s credit return policy. 
• Customer pays return freight. 
 
PLEASE SHIP AUTHORIZED RETURNS TO: 
Sensata Technologies | Power Controls White Bear | 4467 White Bear Parkway | St. Paul, MN 55110 
Return Freight Prepaid 
 
LIMITED WARRANTY: 

Sensata Technologies extends the following warranty to the original purchaser of those goods subject to the qualifications 
indicated. Sensata warrants to the original purchaser for use that the goods or any component thereof manufactured by 
Sensata will be free from defects in workmanship from the date of purchase for the period listed on the product label, 
provided such goods are installed, maintained and used in accordance with Sensata and the original manufacturer’s 
written instructions. Damages caused by the misuse, undue care or obvious wear through use will not be covered by this 
warranty. 
 
Components not manufactured by Sensata, but used within the assembly provided by Sensata, are subject to the 
warranty period as specified by the individual manufacturer of said component, provided such goods are installed, 
maintained and used in accordance with Sensata and the manufacturer’s written instructions. 
 
Sensata’s sole liability and the Purchaser’s sole remedy for a failure of goods under this limited warranty and for any and 
all claims arising out of the purchase and use of the goods, shall be limited to the repair or replacement of the goods that 
do not conform to this warranty. 
 
To obtain repair or replacement service under the limited warranty, the purchaser must contact the factory for a Return 

Material Authorization (RMA). Once obtained, send the Return Material Authorization Number along with the defective 
part or goods to:  
Sensata Technologies, Power Controls White Bear, 4467 White Bear Parkway, St. Paul, MN 55110. Return Freight Prepaid. 
THERE ARE NO EXPRESS WARRANTIES COVERING THESE GOODS OTHER THAN AS SET FORTH ABOVE. THE IMPLIED 
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED IN DURATION TO ONE 
YEAR FROM DATE OF PURCHASE. 
 
SENSATA TECHNOLOGIES ASSUMES NO LIABILITY IN CONNECTION WITH THE INSTALLATION OR USE OF THE 
PRODUCT, EXCEPT AS STATED IN THIS LIMITED WARRANTY. SENSATA TECHNOLOGIES WILL IN NO EVENT BE LIABLE 
FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. 
 

WARNING:

 LIMITATIONS ON USE: DIMENSIONS

®

 brand products are not intended for use in connection with Life 

Support Systems and for Avionic use. Sensata Technologies makes no warranty or representation in connection with their 
products for such uses. 
 

Содержание 12WA7N

Страница 1: ...DC to AC Power Inverters Pure Sine Wave Output Owner s Manual MODELS 12WA7N 12WA10N...

Страница 2: ...put Wiring Diagram 10 Section 9 Overall Wiring Diagram 11 Physical Description 6 Section 7 Remote On Off Switch 9 Section 5 Inverter Mounting 8 Section 3 Nomenclature 5 Section 6 DC Wire Gauge Fusing...

Страница 3: ...put cables Warning Damage to the Power Inverter will occur if an external AC power source is applied to the inverter s AC hardwire output Warning Power Inverters contain a circuit breaker and capacito...

Страница 4: ...ge Any 120 VAC 60 Hz single phase product within the inverter s power rating INVERTER MODEL 12WA7N 12WA10 Dimensions LxWxH Inches Efficiency Input Current Amps DC Up to 70 Up to 100 Input Voltage Volt...

Страница 5: ...put Voltage 12 12VDC DI Dimensions Inverters Other Suffixes designates private label customer Pure Sine Signal Output Output Wattage 7 700 watt 10 1000 watt Chassis Designation WA N 3 Letter Suffix De...

Страница 6: ...ontrolled fan triggers only when necessary to cool down inside electronics 5 DC Field Wiring Compartment Provides access to the Positive Negative DC input lugs 6 DC input Openings Positive Negative Al...

Страница 7: ...er is operating from batteries in inverter mode 3 Low battery The Red LED indicates that the inverter is in a low battery voltage condition and will shutdown 4 Overload The Red LED indicates that the...

Страница 8: ...e The inverter mounting location should provide adequate ventilation and clearance to maintain room temperature during operation At least 1 2 inch of clearance is required on all sides 1 Locate a suit...

Страница 9: ...stranded copper cables in all cases 2 Use SGX cross linked polyurethane insulation type that complies with the high temperature insulation requirements 125 C of SAE J 1127 and vehicle manufacturer req...

Страница 10: ...the load side of the remote On Off switch to the cable lead extending from the inverter and the fused side to the positive post of the battery 6 Install the in line fuses removed in step 1 in the fus...

Страница 11: ...11 Form 122175 9 OVERALL WIRING DIAGRAM FIGURE 5 Typical AC DC wiring diagram Auxiliary battery configuration...

Страница 12: ...The green LED On will come on The AC power produced by the inverter comes from the energy stored in the battery bank through a sophisticated electronic inversion process A transformer a Metal Oxide Si...

Страница 13: ...t outlet make sure all breakers are reset If test light is on Check your AC connections and loads If test light is off Possible bad GFCI or transfer relay 1 3 Green LED External Power on Repeat 1 2 st...

Страница 14: ...d 14ft 18 gauge cable dash mount 611522 Remote switch panel kit with fuse and 14ft 18 gauge cable electrical box mount 140004 Battery box single group 31 250018 Ventilation assembly battery box 42in l...

Страница 15: ...f those goods subject to the qualifications indicated Sensata warrants to the original purchaser for use that the goods or any component thereof manufactured by Sensata will be free from defects in wo...

Страница 16: ...7 White Bear Parkway St Paul MN 55110 Phone 651 653 7000 800 553 6418 Fax 651 653 7600 888 439 3565 inverterinfo sensata com www dimensions sensata com Form 122175 03 25 2013 Sensata Technologies 2013...

Отзывы: