background image

 

 

 

 10 

Form 

122175 

 

8. DC INPUT WIRING DIAGRAM 

 
 

 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 

FIGURE 4: 

Inverter Cable Assembly and Remote On/Off Switch Assembly Kit 

C

a

bl

e

 C

o

nn

e

c

ti

on

 P

roc

e

d

u

re

1) 

R

e

mo

ve the

 i

n

-l

ine fus

e

fr

om the 

fuse-hol

ders for 

cable 

in

st

allatio

n

.

2) C

o

nnect

 the

 i

n

verter’s bonding l

u

g t

o

 gr

ound

 o

r vehicle

 ch

assis

3) 

C

o

nnect

 the

 “in

v

erter cabl

e” se

to

 t

he app

rop

riat

e

 DC input

 lug

s

T

ight the 

stra

in r

e

lief to 

ho

ld

 t

he cabl

es in

 pl

ace. 

4) 

C

o

nnect

 the

 rin

g

 t

e

rmina

ted

 e

nds of t

he “i

nvert

e

ca

ble

” set

 d

irect

ly

 t

o

 the app

rop

riat

e

 bat

te

ry 

post.

 

   

 Make 

sure t

h

e

 ba

ttery 

p

o

la

ri

ty 

is

 ob

served.

5) 

C

o

nnect

 the

 l

oad sid

e

 of the 

“rem

ote 

O

n

/O

ff

” s

w

it

ch 

to the

 cab

le le

ad ext

ending 

fr

om

 th

e

 inver

ter an

th

e

  

  

fu

sed 

si

de

 to 

th

e

 p

o

si

ti

ve

 p

o

st

 of

 t

he bat

tery.

6) 

In

sta

ll 

the in-l

in

e

 fuses r

e

moved i

n

 st

ep (1)

 i

n

 the

 f

u

se-ho

lder

s. 

A

 t

y

pi

cal o

ne t

im

e

 sp

ark 

w

ill occur 

w

h

en 

th

is

 final

  

  conne

ct

ion 

is 

m

ade. 

Pl

ug 

the

 f

la

t cable t

o

 the back 

of

 the remot

e

 p

anel

 f

o

in

vert

er 

op

er

at

ion.

2

2

3

3

8-ga

uge

1/4" Rin

g

 

Te

rm

inal

18"

Fu

seholder

Fu

se

20

M

a

ximum,

 R

ed Ca

bl

e:

 Posit

ive 

(+)

20' Maxim

u

m,

 Black 

C

a

ble

: Ne

gative (

-)

3

/8" R

ing 

Te

rm

inals

1

4

4

 PO

S

.  

 

NEG

.

Fast on

AC

 Out

put

N

o

te

: u

n

screw

 th

e i

n

v

e

rte

r’

s

 f

ace 

plat

e

 to

 a

ccess

 the D

C

 l

u

gs 

Fuse &

 Fu

seholder

O

n

/O

ff

 S

w

it

ch

18

-g

auge

5-Amp

Singl

e P

o

le

Singl

e Throw

Re

m

o

te

 “O

n/

O

ff Switch”

 - 

Custo

m

e

sup

p

lied opt

io

n

 

18

"

5

1

Red

/V

iolet

 C

able

3

3

5

R

ear Vie

w

Side V

iew

Содержание 12WA7N

Страница 1: ...DC to AC Power Inverters Pure Sine Wave Output Owner s Manual MODELS 12WA7N 12WA10N...

Страница 2: ...put Wiring Diagram 10 Section 9 Overall Wiring Diagram 11 Physical Description 6 Section 7 Remote On Off Switch 9 Section 5 Inverter Mounting 8 Section 3 Nomenclature 5 Section 6 DC Wire Gauge Fusing...

Страница 3: ...put cables Warning Damage to the Power Inverter will occur if an external AC power source is applied to the inverter s AC hardwire output Warning Power Inverters contain a circuit breaker and capacito...

Страница 4: ...ge Any 120 VAC 60 Hz single phase product within the inverter s power rating INVERTER MODEL 12WA7N 12WA10 Dimensions LxWxH Inches Efficiency Input Current Amps DC Up to 70 Up to 100 Input Voltage Volt...

Страница 5: ...put Voltage 12 12VDC DI Dimensions Inverters Other Suffixes designates private label customer Pure Sine Signal Output Output Wattage 7 700 watt 10 1000 watt Chassis Designation WA N 3 Letter Suffix De...

Страница 6: ...ontrolled fan triggers only when necessary to cool down inside electronics 5 DC Field Wiring Compartment Provides access to the Positive Negative DC input lugs 6 DC input Openings Positive Negative Al...

Страница 7: ...er is operating from batteries in inverter mode 3 Low battery The Red LED indicates that the inverter is in a low battery voltage condition and will shutdown 4 Overload The Red LED indicates that the...

Страница 8: ...e The inverter mounting location should provide adequate ventilation and clearance to maintain room temperature during operation At least 1 2 inch of clearance is required on all sides 1 Locate a suit...

Страница 9: ...stranded copper cables in all cases 2 Use SGX cross linked polyurethane insulation type that complies with the high temperature insulation requirements 125 C of SAE J 1127 and vehicle manufacturer req...

Страница 10: ...the load side of the remote On Off switch to the cable lead extending from the inverter and the fused side to the positive post of the battery 6 Install the in line fuses removed in step 1 in the fus...

Страница 11: ...11 Form 122175 9 OVERALL WIRING DIAGRAM FIGURE 5 Typical AC DC wiring diagram Auxiliary battery configuration...

Страница 12: ...The green LED On will come on The AC power produced by the inverter comes from the energy stored in the battery bank through a sophisticated electronic inversion process A transformer a Metal Oxide Si...

Страница 13: ...t outlet make sure all breakers are reset If test light is on Check your AC connections and loads If test light is off Possible bad GFCI or transfer relay 1 3 Green LED External Power on Repeat 1 2 st...

Страница 14: ...d 14ft 18 gauge cable dash mount 611522 Remote switch panel kit with fuse and 14ft 18 gauge cable electrical box mount 140004 Battery box single group 31 250018 Ventilation assembly battery box 42in l...

Страница 15: ...f those goods subject to the qualifications indicated Sensata warrants to the original purchaser for use that the goods or any component thereof manufactured by Sensata will be free from defects in wo...

Страница 16: ...7 White Bear Parkway St Paul MN 55110 Phone 651 653 7000 800 553 6418 Fax 651 653 7600 888 439 3565 inverterinfo sensata com www dimensions sensata com Form 122175 03 25 2013 Sensata Technologies 2013...