1. SAFETY INSTRUCTIONS 

 

IMPORTANT:

 Read this manual before installation, it contains important safety, 

installation, and operating instructions. Save this manual and keep it in a safe place. 
 
 
 
 

Sensata Technologies is an ISO 9001:2008 Registered Company 

 

1.1 Inverter Safety Instructions: 

 

 

Warning: Power Inverters produce hazardous voltages. To avoid risk of 

harm or fire, the unit must be properly installed. 

 

Warning: There are no user serviceable parts inside, do not remove the 

cover. 

 

Warning: Power Inverters should not be mounted in a location that may be 

exposed to rain or spray. 

 

Warning: Power Inverters should not be installed in a zero clearance 

enclosure. 

 

Warning: Damage to the Power Inverter will occur if correct polarity is not 

observed when installing the inverter’s DC input cables. 

 

Warning: Damage to the Power Inverter will occur if an external AC power 

source is applied to the inverter’s AC hardwire output. 

 

Warning: Power Inverters contain a circuit breaker and capacitor that may 

produce a spark. Do not mount in a confined battery or gas compartment. 

 

Warning: Be sure the Power Inverter is turned OFF during installation. 

 

1.2 Battery Safety Information: 

 

 

Warning: Working in the vicinity of lead-acid batteries is dangerous. There 

is a risk of acid exposure.  

 

Warning: Batteries generate explosive gases during operation.  

 

Warning: There is risk of high current discharge from shorting a battery that 

can cause fire and explosion. Use insulated tools during installation. 

 

Warning: Remove all rings, watches, jewelry or other conductive items 

before working near the batteries. 

 

Warning: Inspect the batteries once a year for cracks, leaks or swelling. 

 

Warning: Dispose of the batteries according to local regulations. Do not 

incinerate batteries; risk of explosion exists.  
 

Содержание 12WA7N

Страница 1: ...DC to AC Power Inverters Pure Sine Wave Output Owner s Manual MODELS 12WA7N 12WA10N...

Страница 2: ...put Wiring Diagram 10 Section 9 Overall Wiring Diagram 11 Physical Description 6 Section 7 Remote On Off Switch 9 Section 5 Inverter Mounting 8 Section 3 Nomenclature 5 Section 6 DC Wire Gauge Fusing...

Страница 3: ...put cables Warning Damage to the Power Inverter will occur if an external AC power source is applied to the inverter s AC hardwire output Warning Power Inverters contain a circuit breaker and capacito...

Страница 4: ...ge Any 120 VAC 60 Hz single phase product within the inverter s power rating INVERTER MODEL 12WA7N 12WA10 Dimensions LxWxH Inches Efficiency Input Current Amps DC Up to 70 Up to 100 Input Voltage Volt...

Страница 5: ...put Voltage 12 12VDC DI Dimensions Inverters Other Suffixes designates private label customer Pure Sine Signal Output Output Wattage 7 700 watt 10 1000 watt Chassis Designation WA N 3 Letter Suffix De...

Страница 6: ...ontrolled fan triggers only when necessary to cool down inside electronics 5 DC Field Wiring Compartment Provides access to the Positive Negative DC input lugs 6 DC input Openings Positive Negative Al...

Страница 7: ...er is operating from batteries in inverter mode 3 Low battery The Red LED indicates that the inverter is in a low battery voltage condition and will shutdown 4 Overload The Red LED indicates that the...

Страница 8: ...e The inverter mounting location should provide adequate ventilation and clearance to maintain room temperature during operation At least 1 2 inch of clearance is required on all sides 1 Locate a suit...

Страница 9: ...stranded copper cables in all cases 2 Use SGX cross linked polyurethane insulation type that complies with the high temperature insulation requirements 125 C of SAE J 1127 and vehicle manufacturer req...

Страница 10: ...the load side of the remote On Off switch to the cable lead extending from the inverter and the fused side to the positive post of the battery 6 Install the in line fuses removed in step 1 in the fus...

Страница 11: ...11 Form 122175 9 OVERALL WIRING DIAGRAM FIGURE 5 Typical AC DC wiring diagram Auxiliary battery configuration...

Страница 12: ...The green LED On will come on The AC power produced by the inverter comes from the energy stored in the battery bank through a sophisticated electronic inversion process A transformer a Metal Oxide Si...

Страница 13: ...t outlet make sure all breakers are reset If test light is on Check your AC connections and loads If test light is off Possible bad GFCI or transfer relay 1 3 Green LED External Power on Repeat 1 2 st...

Страница 14: ...d 14ft 18 gauge cable dash mount 611522 Remote switch panel kit with fuse and 14ft 18 gauge cable electrical box mount 140004 Battery box single group 31 250018 Ventilation assembly battery box 42in l...

Страница 15: ...f those goods subject to the qualifications indicated Sensata warrants to the original purchaser for use that the goods or any component thereof manufactured by Sensata will be free from defects in wo...

Страница 16: ...7 White Bear Parkway St Paul MN 55110 Phone 651 653 7000 800 553 6418 Fax 651 653 7600 888 439 3565 inverterinfo sensata com www dimensions sensata com Form 122175 03 25 2013 Sensata Technologies 2013...