2.1.2.3
Battery protection
The evaluation board includes an on-board circuit that protects against overcurrent, over voltage and
under voltage. SW1 (battery connect/disconnect switch) switches the battery connection circuit
connects and disconnects the battery from the board circuit.
shows SW1 “battery connect”
and “battery disconnect” positions.
When in
“
battery disconnect
”
position, power for the system is only drawn from one of the two USB-C
connectors. In this configuration the battery is not charged.
In the
“
battery connect
”
position, power for the system is drawn from the USB-C. If more power is
needed than what USB-C can provide, then battery is used to supply the excessive power. If there is
excessive power on the USB-C, it is used to charge the battery.
Figure 11: SW1 (battery connect switch) positions
☞
Every time the battery is physically removed from the holder, the battery protection circuit
changes to disconnect state (for battery saving reasons). To change to normal state again, a
connection with an external charger should be done.
2.1.3
NORA-W106
NORA-W106 can be programmed with the main application code.
of NORA-W106 to different functions.
NORA-W106 pin
ESP32-S3 GPIO
Function
F7
GPIO0 / Boot
BOOT0/BUTTON-1
C8
GPIO21
BUTTON-2
A3
GPIO17 (A)
I2C-SCL
B4
GPIO18 (A)
I2C-SDA
H9
GPIO8 (A)
LED-B
H8
GPIO2 (A)
LED-G
J8
GPIO5 (A)
LED-R
E8
GPIO1 (A)
MB1-AN
D8
GPIO4 (A)
MB1-INT
E9
GPIO7 (A)
MB1-PWM
E7
GPIO9 (A)
MB1-RST