background image

SCR053 

Sensor  Remote  Programmer 

OPERATION  INSTRUCTIONS 
SPECIFICATIONS 

Power  supply 

2 x AAA 1. 5V  battery,  Alkaline preferred 

Carrying case 

RC-100 in carrying case 

Communication  940 nm Infrared Tx &  Rx 
Upload  range 

Up  to  15 m  (50 ft.) 

Op.  temperature  0

°

C-50

°

C (32

°

F-122

°

F) 

Dimensions 

123x70x20.3 mm (4. 84"x2.76" xO. 8") 

REMOTE 

with carrying case 

WARNING

Remove  the  batteries  from  compartment  if  the  remote will  not  be  used  in  30  days. 

OVERVIEW 

The remote control  Wireless IR Configuration Tool is a handheld tool for remote configuration of 

IR-enabled fixture integrated sensors.  The tool enables device to modify via pushbutton without 

ladders or tools,  and stores up to four sensor parameter modes to speed configuration of multiple 

sensors. 

The remote control uses bidirectional IR communication to send and receive sensor settings at 

mounting height up to 50 feet. The device can display previously established sensor parameters, 

copy parameters and send new parameters or store parameter profiles.  For projects where identical 

settings may be desired across a large number of areas or spaces,  this capability provides a 

streamlined method of configuration. Settings can be copied throughout a site,  or in different sites. 

LED INDICATORS 

LED 

DESCRIPTION 

LED 

DESCRIPTION 

To select the current surrounding lux 

To Set the output level (in%) of 

value  as the daylight threshold. This 

BRIGHTNESS  connected lighting during 

@ 

feature enables the fixture to function 

occupancy 

well in any real application 

circumstances. 
The built-in daylight sensor stops 

SENSITIVITY  To set the occupancy sensing

@ 

working, and all motion detected 

sensitivity of the Sensor 

could turn on the lighting fixture, no 

matter how b

ight the natural light is. 

To set the output level (in%) of 

The time that the Sensor will turn 

connected lighting during vacancy. 

HOLD TIME  off(if you choose stand-by level is STAND-BY DIM  The sensor will regulate the lighting

0) or dim the light to a low level 

output at the set level. Setting the 

after the area is vacated 

STAND BY DIM at O means light full 

off during vacancy. 

DAYLIGHT  To represents various thresholds of 

To represents the time that the 

SENSOR 

natural light level for the Sensor . 

STAND-BYTIME  Sensor will keep the light at low dim 

level after the HOLD TIME elapsed. 

BUTTON  OPERATION 

BUTTON 

DESCRIPTION 

BUTTON 

DESCRIPTION 

Press the "ON/OFF" button, the 

light goes to pe

manent on or 

Press "Auto" button, the sensor starts to 

@ 

permanent off mode, and the 

function and all settings remain the same 

sensor is disabled.(MUST press 

as the latest status before the light is 

"Auto"button to quit this mode for 

switched on/off. 

Setting. 

Display the current/lastest setting 

The button" TEST" is for testing purpose 

令)

parameters in LED indicators(the 

sens仆ivity only. afle

you choose sens仆ivity

LED indicators will on for showing 

thresholds, then you press"TEST" button, 

the setting parameters) 

The sensor goes to test mode(hold time is 

only 2s) automatically ,meanwhile the 

Press "RESET" button, all settings 

stand-by period and daylight sensor are 

go back to  settings of dip Switch in 

disabled Press "AUTO" button to quit from 

sensor 

this mode 

@� 

Enter in the setting condition, and

Press this button for open or close the smart 

Navigate to UP and Down for choose 

photocell sensor which take place of normal 

selected parameters in LED indicators. 

photocell sensor switch  When remote 

control enters in se廿ing conduction, you can 

Navigate to LEFT and RIGHT for 

choose open and close the smart photocell 

�® 

sensor. If this smart photocell sensor open, 

choose selected parameters in 

2 Leds indicators of daylight sensor are on 

LED indicators. 

for choose photocell sensor setpoint on/off 

to light, and Stand by lime is only 8. When 

@ 

Keep records of selected parameters 

the natural light level exceeds setpoint off to 

light, the lights will turn off even if when the 

in remote cont

ol or 1n Mode 1 o

@ 

space is occupied once the natural light 

mode 2 mode 3,mode 4 

level exceeds this setpoint off to light, the 

sensor will wait and monitor for 1 minute in 

Upload the selected parameters to 

order to confirm the natural light level 

increase is not temporary before forcing the 

sensors. 

lights to go off.  When the natural light level 

lower than setpoint on to light, the lights will 

@8 

turn on even when the space is not occupied. 

4 Scene modes with preset 

when natural light level goes lower than this 

setpoint on to light, the sensor will wait and 

parameters which are available to 

monitor for 1 minute in order to confirm the 

@今

be changed and saved in modes

natural light level decrease is not temporary 

before forcing the lights go on 

SETTING 

The SETTING  Content  contains  all  available  settings  and  parameters  for  remote  sensors.  It 

allows  you to change  the  available  control,  parameters,  and  operation  of  the  sensor  from  factory 

default  or current  parameters. 

NOTE:the  setting  works  only  in  Auto  mode. 

Change multiple settings of sensor(s) 

1.Press DISP button(if you push ON/OFF button before you push DISP button, the sensor is locked,

so please push "AUTO" button to unlock the sensor ,and then push DISP button), the controler

leds indicators will show the latest parameters.

2.Press @ or®enter in the setting condition, navigate to the desired setting by pressing

@®@®to select the new parameters.

3.Press ok to confirm all setting and saving.

4.Aim at the target sensor and press SEND to upload the new parameter. light will be one time and off ,

as confirm.

-1-

-2-

Отзывы: