Error! No text of specified style in document. - System Integration Manual
CDMA-2X-11004-P1
Objective Specification
Design-In
Page 66 of 79
Category
Application
Immunity Level
Contact Discharge to coupling planes (indirect contact
discharge)
Enclosure
+2 kV / -2 kV
+4 kV / -4 kV
Contact Discharges to conducted surfaces (direct contact
discharge)
Enclosure port
Not Applicable
5
Contact Discharges to conducted surfaces (direct contact
discharge)
Antenna port
(only antenna with
completely insulating surface
can be used)
Not Applicable
6
Air Discharge at insulating surfaces
Enclosure port
Not Applicable
7
Air Discharge at insulating surfaces
Antenna port
(only antenna with
completely insulating surface
can be used)
+2 kV / -2 kV
+4 kV / -4 kV
+8 kV / -8 kV
Table 20: Enclosure ESD immunity level result, standards “EN 61000-4-2, EN 301 489-1 V1.8.1, EN 301 489-7 V1.3.1” for LISA
application reference design.
74.3.1
General precautions
The following module interfaces can have a critical influence in ESD immunity testing, depending
on the application board handling. The following precautions are suggested:
HW_SHUTDOWN pin (FW75-C200 only)
Sensitive interface is the reset line (HW_SHUTDOWN pin):
A 47 pF bypass capacitor (e.g. Murata GRM1555C1H470JA01) have to be mounted on the line
termination connected to the HW_SHUTDOWN pin to avoid a module reset caused by an
electrostatic discharge applied to the application board enclosure
A series ferrite bead (e.g. Murata BLM15HD182SN1) must be added on the line connected to
the HW_SHUTDOWN pin to avoid a module reset caused by an electrostatic discharge applied
to the application board enclosure
It is recommended to keep the connection line to HW_SHUTDOWN as short as possible
Reset_N pin (LISA-C200 only)
Sensitive interface is the reset line (Reset_N pin):
A 47 pF bypass capacitor (e.g. Murata GRM1555C1H470JA01) have to be mounted on the line
termination connected to the Reset_N pin to avoid a module reset caused by an electrostatic
discharge applied to the application board enclosure
5
LISA mounted on application design:
Not Applicability -> EUT with insulating enclosure surface, EUT without enclosure surface
Applicability -> EUT with conductive enclosure surface
6
LISA mounted on application design:
Not Applicability -> Antenna with insulating surface
Applicability -> Antenna with conductive surface
7
LISA mounted on application design:
Applicability -> EUT with insulating enclosure surface
Not Applicability -> EUT with conductive enclosure surface, EUT without enclosure surface