LISA-C2 series and FW75-C200 - System Integration Manual
UBX-13000620 - R21
Early Production Information
Appendix
Page 96 of 103
LISA-C200 modules cannot be switched on by
RESET_N
pin, as provided by LISA-U series modules.
LISA-C200 offers a 5-wire UART interface (
TxD, RxD, RTS, CTS
and
RI
lines only): pins 9, 11, and 12 are
Reserved (
RSVD
) on LISA-C200 that do not provide
DSR
,
DCD,
and
DTR
signals as done so with LISA-U series
modules. For LISA-C200, these three Reserved pins are to be left unconnected.
The firmware of LISA-C200 cannot be upgraded by UART interface, but can be upgraded by USB interface.
LISA-C200 doesn’t provide SPI / IPC interface as LISA-U series modules: these related pins 55, 56, 57, 58, and 59
are Reserved (
RSVD
).
LISA-C200 provides one USB communications device class over a full-speed USB 2.0 interface on the
USB_D+
and
USB_D- pins
instead of multiple USB communications device classes over a high-speed USB 2.0 interface
provided by LISA-U series modules. The
VUSB_DET
input pin on the LISA-U series modules, is provided to sense
the VBUS (5 V typical) USB supply provided by the USB host.
LISA-C200 can support an external SIM (RUIM) card by the SIM interface pins. Contact u-blox support if this
feature is needed.
LISA-C200 provides an analog audio interface (
MIC_N, MIC_P
differential input and
SPK_P, SPK_N
differential
output) compatible with LISA-U120 and LISA-U130, but the other LISA-U series modules don’t provide the same
functionality on the paired pins 39, 40 and 53, 54.
LISA-C200 provides a PCM digital audio interface (
PCM_SYNC, PCM_DO, PCM_CLK, PCM_DI
) comparable
with the digital audio interface provided by LISA-U120, LISA-U130, LISA-U230 and LISA-U200. Migration from
LISA-U series is possible according to external device capabilities.
Pin 52 is Reserved (RSVD) on LISA-C200, while LISA-U230 and LISA-U200 provide a clock output (
CODEC_CLK
).
Leave this pin unconnected on LISA-C200.
LISA-C200 provides GPIOs (
GPIO1 to GPIO5
) on the pins 20, 21, 23, 24 and 51, as does the LISA-U series, but
LISA-U series modules provide additional functionalities.
LISA-C200 operating temperature range (refer to
LISA-C2 series Data Sheet
[1]) is comparable to LISA-U series
modules, but LISA-C200 doesn’t support embedded Smart Temperature Supervisor as LISA-U series modules.
The LISA-C200 is an SMT module and comes in the same compact form factor of LISA-U series, featuring
Leadless Chip Carrier (LCC) packaging technology. The signals keep-out area must be implemented on the top
layer of the application board, due to GND openings on module bottom layer.
Detailed pin assignment and layout comparisons between LISA-U series and LISA-C200 modules, with
remarks for migration, are provided in “Pin-out comparison LISA-U series vs. LISA-C200 module”
section of this
appendix. For more information regarding the LISA-C200 module’s electrical characteristics, refer to the
LISA-C2
series Data Sheet