LISA-C2 series and FW75-C200 - System Integration Manual
UBX-13000620 - R21
Early Production Information
Features description
Page 78 of 103
Figure 42: AT+UOMADMCLEAN practical use
+UOMADMCLEAN use is not needed from version 03S / 23S onwards
3.5.2.9
FACTORY ENVIRONMENT
3.5.2.9.1
OMA-DM provisioning
Given that in a factory environment the OMA-DM session will start during the testing process, it is highly
recommended to include a checking routine to make sure the reg.conf file isn’t halting the OMA-DM sessions,
or to leave the device on factory default values.
The factory setup procedure should be:
1.
Check for DC values.
•
AT$MDN? Returns : 000000XXXX
•
AT$MSID? Returns : 000000XXXX
•
AT$QCMIPGETP=1 : Returns : [email protected]
2.
Check for +UOMASTAT URC messages.
3.
Allow 45 seconds from the C200 device’s power up and monitor the URCs. If no URCs received, then
execute: AT+UOMADMCLEAN=0.
4.
Check for DC values.
5.
If no +UOMASTAT URC is received, use:
•
AT+OMADM=2 to force a start
6.
If still no URC is seen, perform AT$RTN=000000.
7.
Allow for the URC +UOMASTAT to be displayed.
8.
If the device needs to be powered down, then execute: AT+CPWROFF and allow 5 seconds to
disconnect the power source.
9.
You can check if the device has been ever provisioned with AT+UPROVSTATE?
a.
+PROVSTATE: 0 response means it has never been provisioned before
b.
+PROVSTATE: 1 response means it has been provisioned before