9
SELF-INSPECTION OF THE INSTALLATION
To check the installation:
1. Turn power on at the Circuit Breaker Box.
2. Check that the control panel lights up.
3. Start the heater (see User Guide).
4. Check that all three tubular elements start to heat up (go
red).
Please keep these instructions!.
In the event of problems, please contact the retailer where you purchased
the equipment.
© This publication many not be reproduced, in part or in whole, without
the written permission of Tylö. Tylö reserves the right to make changes to
materials, construction and design.
1
2
3
4
Pin:
Pos 1A.
NTC
Pin 1:
Pin 2: NTC
Pin 3: NTC
Pin 4:
Pos 2A.
Ext sw
Pin 1:
Pin 2: LED
Pin 3: SW
Pin 4: 12 V
Pos 6A-9A.
4x RS485
Pin 1: A
Pin 2: B
Pin 3: 12 V
Pin 4: GND
Pos 5B-8B.
4x RS485
Pin 1: A
Pin 2: B
Pin 3: 12 V
Pin 4: GND
Pos 3A.
Door sw
Pin 1:
Pin 2: LED
Pin 3: SW
Pin 4: 12 V
Pos 4A.
Bim/NTC
Pin 1: Bim
Pin 2: NTC
Pin 3: NTC
Pin 4: Bim
Pos 1B.
NTC
Pin 1:
Pin 2: NTC
Pin 3: NTC
Pin 4:
Pos 2B.
Ext sw
Pin 1:
Pin 2: LED
Pin 3: SW
Pin 4: 12 V
Pos 3B.
Door sw
Pin 1:
Pin 2: LED
Pin 3: SW
Pin 4: 12 V
Pos 4B.
Bim/NTC
Pin 1: Bim
Pin 2: NTC
Pin 3: NTC
Pin 4: Bim
Pos 5A.
Addon (option)
1
2
3
4
Pin:
10
11
1A
2A
6A
7A
8A
9A
3A
4A
5A
1B
2B
3B
4B
5B
6B
7B
8B
ELITE
PURE
Description of cabling/modular contacts
Figure 19: Modular contacts, description
ELITE
(Pos 1-4 and 6-9: RJ10, Pos 5: RJ45)
1A. NTC Sensor
2A. Ext switch (optional)
3A. N/A
4A. N/A
5A. N/A
6A. N/A
7A. N/A
8A. N/A
9A. Controls Elite
10. Modular plug (RJ10)
11. Modular contact (RJ10)
PURE
(Pos 1-8: RJ10)
1B. NTC Sensor
2B. Ext switch (External switch
optional)
3B. N/A
4B. N/A
5B. N/A
6B. N/A
7B. N/A
8B. Controls Pure
10. Modular plug (RJ10)
11. Modular contact (RJ10)
Table 3: Connecting components in modular contacts (maximum cable area for RJ10: 0.90 mm/0.20 mm², AWG24)
Connection of
Pos
Pin
Comment
Temp. sensor (10kohm)
1 A/B
2-3
Must be NTC model.
External switch with no wire indicator 2 A/B
3-4
Both constant or impulse deactivation works.
External switch with wire indication
2 A/B
2-3-4
12VDC (max. 40mA).
NOTE!
Crimp pliers are needed if changing modular
cabling, e.g. shortening wires.