background image

11

USER GUIDE

GENERAL INFORMATION

Congratulations on your new sauna heater! Follow this user guide 
to get the most from your purchase.
Wet and dry saunas are forms of bathing which originate way 
back in history. A hot sauna is best enjoyed at temperatures be-
tween 145-190°F.

PRIOR TO USE

The fi rst time you use the heater

Fill the stone compartment

Fill the stone compartment around the heating elements from the 
bottom to the top, to approx. 2” above the top front edge. Do not 
press the stones into place. Capacity: Approx. 35 lb of stones.
Place the stones loosely to allow optimum air circulation. The tu-
bular heating elements must not be squeezed together or against 
the side.

Sauna stones must:
• 

tolerate extreme heat and fl uctuations caused by water being 
poured on them.

• 

be cleaned before use.

• 

must have an uneven surface, so that the water "clings" to 
the stone surface and evaporates effi  ciently.

• 

be between 1-1/2” to 2” in size to allow air circulation in the 
stone compartment. This will increase the life of the tubular 
elements.

Default settings

Using the control panel for the fi rst time:

See instructions supplied with the control panel. 

Prior to each use

Check the following
Check that:
• 

there are no foreign objects in the sauna cabin, on or in the 
heater.

• 

the door and any windows to the sauna cabin are closed.

• 

that the sauna door opens outwards with a little pressure.

NB:

DANGER! Fragrant essences and similar prod-
ucts may ignite, if poured directly onto the 
stones.

Figure 2: Positioning of the main power switch

1.  Main power switch

Figure 1: Filling the stone compartment

1.  Stone compartment
2.  Side chambers

Turn on the heater to remove any new paint odors
To remove "new paint odor" from the heater:
Heat the sauna heater for about one hour. The water reservoir 
does not need to be working.
A little smoke may appear.

NB: Always use dolerite stones (Tylö Sauna Stones)! 
"Ordinary" stones may damage the heater.
Do not use ceramic stones. Ceramic stones may 
damage the heater. The heater guarantee does not 
cover damage caused by ceramic stones.

NB: Never place stones on top of the side air 
chambers. This way will obstruct air circulation, 
causing the unit to overheat and the cut-out switch 
to activate.

1

2

NOTE! 

Do not use the sauna cabin for any purpose 

other than taking saunas.

Turn on the main power switch

The main power switch is at the bottom of the heater.
Switch it on, if it is not already switched on (see Figure 2).

1

Содержание Sense Combi USA Elite

Страница 1: ...2016 10 18 2900 5280 SENSE PURE ELITE USA ENGLISH INSTALLATION USER GUIDE FRANÇAIS NOTICE D INSTALLATION ET D UTIL ISATION ...

Страница 2: ...ehold only Keep this user guide In the event of any problems please contact the re tailer where you purchased the equipment This publication may not be reproduced in part or in whole without the written permission of Tylö Tylö reserves the right to make changes in materials construction and design Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above t...

Страница 3: ...ake vent see the Air intake vent positioning section page 5 Position the air exhaust vent see the Air exhaust vent posi tioning section page 5 Plan the electrical installation see the Connection wiring diagram section page 8 2 8 6 7 15 5 1 3 4 9 10 11 12 13 14 16 Table 1 Voltage and sauna volume Model Voltage Sauna volume min cu ft Sauna volume max cu ft Sense U 7 Elite Pure SPU7 208 V 240 V 175 1...

Страница 4: ... in from heater 3 Sensor 4 Minimum distance from back wall with legs 4 in 5 Sensor position option 2 3 in from heater front 6 Sensor position 1 in from ceiling 7 Minimum distance from ceiling 44 in 8 Minimum distance from interior fittings 4 in 9 Minimum ceiling height 75 in 10 Minimum distance 1 in 11 Minimum distance from interior fittings 2 in 12 Suggested distance from floor 7 in Positioning the ...

Страница 5: ...he rock guard upwards see Figure 7 This is necessary when filling the stone compartment or cleaning the fragrance holder and air humidifier 1 2 3 4 Figure 7 Removing the Rock Guard Room construction For safety and reliability the following rules must be addressed The enclosed WARNING Reduce the risk of overheating warning plate must be mounted on or alongside the door outside the sauna room at about...

Страница 6: ... and tighten the screws see Figure 9 2 8 4 5 7 6 9 1 10 3 11 Figure 10 Circuit board 1 Electrical cable 2 Terminal for connection of elec trical cable 3 Cable grommet x6 4 Control panel cable 5 Modular contacts for connection of control panel sensor etc 6 Sensor cable 7 Light cable if connected 8 Terminal for connection of light if connected 9 Strain relief connector for cables to modular contacts...

Страница 7: ...tructions supplied with the control panel Figure 13 Fitting the fragrance holder air humidifier 11 Hang the heater on the screws see Fig 14 Figure 14 Hang the heater up 12 Lock the heater into place with the lock screw see Fig 15 Figure 15 Lock screw for bracket 13 Install the sensor on the wall see Fig 16 The thermistor wire may also be passed through the wall Seal any holes in the wall behind th...

Страница 8: ... of light 14 Door contact option 15 External switch option 10 13 14 15 12 11 13 RJ10 4P4C 3 x 14 AWG RJ10 4P4C RJ10 4P4C ELITE PURE max 75 feet B G B 41 40 1 2 6 7 8 9 3 4 5 1A 2A 6A 7A 8A 9A 3A 4A 5A 120 V 14 AWG Max 6 Amp 5 3 8 3 kW 208 240 V 1B 2B 3B 4B 5B 6B 7B 8B CONNECTION WIRING DIAGRAM TAB 208 V 1 Phase 240 V 1 Phase Model Amperage Amps Output kW Wire Size AWG Amperage Amps Output kW Wire ...

Страница 9: ... Pin 4 Pos 2B Ext sw Pin 1 Pin 2 LED Pin 3 SW Pin 4 12 V Pos 3B Door sw Pin 1 Pin 2 LED Pin 3 SW Pin 4 12 V Pos 4B Bim NTC Pin 1 Bim Pin 2 NTC Pin 3 NTC Pin 4 Bim Pos 5A Addon option 1 2 3 4 Pin 10 11 1A 2A 6A 7A 8A 9A 3A 4A 5A 1B 2B 3B 4B 5B 6B 7B 8B ELITE PURE Description of cabling modular contacts Figure 19 Modular contacts description ELITE Pos 1 4 and 6 9 RJ10 Pos 5 RJ45 1A NTC Sensor 2A Ext...

Страница 10: ...10 14 8 1 6 375mm 17 0 23 6 431mm 600mm 41mm 206mm 8 11 262mm 262mm 10 31 262mm 10 31 DIMENSIONS ...

Страница 11: ...plied with the control panel Prior to each use Check the following Check that there are no foreign objects in the sauna cabin on or in the heater the door and any windows to the sauna cabin are closed that the sauna door opens outwards with a little pressure NB DANGER Fragrant essences and similar prod ucts may ignite if poured directly onto the stones Figure 2 Positioning of the main power switch...

Страница 12: ...eek Example If the unit is used 3 times a week check the stone compartment 3 times per year How to check the stone compartment 1 Remove all stones from the compartment 2 Remove any small stones gravel and limescale from the compartment 3 Put whole undamaged stones back Replace damaged sto nes with new ones as required see Filling the stone compart ment page 5 Air humidifier DANGER Fragrant essences...

Страница 13: ...ed the heater cannot be started again until the temperature has dropped down 68 degrees ºF on the PCA Heater The temperature cut out in the heater protects the com ponents and woodwork in the sauna from overheating There is a white reset button on the left side of the heater which must be pressed in see Fig 9 If the heater safety switch has activated the button will feel stiff and will click when r...

Страница 14: ... Transformer on PCB in heater faulty 6 Control panel faulty 1 Turn heater main power switch 2 Check and replace reset the fuses in the main switchboard 3 Switch off heater main power switch and connect each paired cable to the control panel Switch on heater main power switch again If this does not help an authorized electrician is required to find the fault 4 Requires an authorized electrician to fin...

Страница 15: ... authorities for details of your nearest recycling centre ROHS RESTRICTION OF HAZARDOUS SUBSTANCES Instructions for environmental protection Do not dispose of this product with the domestic refuse when no longer in use Take it to a recycling station for electrical and elec tronic equipment instead For further information see the symbol on the product manual or packaging SPARE PARTS LIST Figure 7 S...

Страница 16: ... 208 240V 1 ph FRONT MIDDLE BACK GND GND Switch Circuit board Type kW Amp Amp 208 V 240 V AWG AWG Sense Plus U 7 Sense Plus U 8 5 3 6 3 7 0 8 3 26 30 10 8 30 35 8 8 Use only 194 F copper wire Don t forget to earth ground 120 V N 1 3 4 2 High Limit Control Heater AWG 14 Max 6 Amp 120 Volt Light input Separate from Heater Power Output to light HEATER WIRING DIAGRAM ...

Страница 17: ...e revendeur où vous avez acheté le matériel Cette publication ne peut être reproduite en tout ou en partie sans la permission écrite de Tylö Tylö se réserve le droit d apporter des modifica tions dans les matériaux dans la construction et dans la conception L hyperthermie survient lorsque la température interne du corps atteint un niveau de plusieurs degrés au dessus de la température normale de 37...

Страница 18: ... nationaux et locaux du pays où le système est installé La taille du fusible A et la taille du câble d alimentation AWG doivent être adaptées au poêle voir le paragraphe intitulé Schéma de raccordement branchement Page 23 La ventilation du sauna doit se conformer aux instructions de ce manuel voir le paragraphe intitulé Emplacement de l entrée d air Page 20 le paragraphe intitulé Emplacement de la...

Страница 19: ...o 10 Distance minimale 25 mm 1 po 11 Distance minimale par rapport aux aménagements 50 mm 2 po 12 Distance par rapport au sol 18 mm 7 po Emplacement du panneau de commande Le panneau de commande peut être monté à l intérieur ou à l ex térieur de la cabine de sauna Le panneau de commande doit être correctement positionné en ce qui concerne les distances de sécurité ci dessous lorsqu il est installé...

Страница 20: ... humidificateur 1 2 3 4 Fig 7 Retrait du protège pierres Conception de la cloison Les règles suivantes doivent être observées pour des raisons de sécurité et de fiabilité L AVERTISSEMENT ci joint Réduire le risque de surchauffe la plaque d avertissement doit être montée sur ou à côté de la porte à l extérieur du sauna au niveau des yeux Utili sez les vis fournies Le texte de PRUDENCE ci joint Réduire...

Страница 21: ...ique 1 Câble électrique 2 Bornier pour le raccordement du câble électrique 3 Passe câble x6 4 Câble du panneau de comman de 5 Prises modulaires pour le raccordement du panneau de commande de la sonde etc 6 Câble de sonde 7 Câble d éclairage le cas échéant 8 Bornier pour le raccorde ment de l éclairage le cas échéant 9 Connecteur anti arrachem ent pour câbles des prises modulaires x2 10 Connecteur ...

Страница 22: ...mmande Fig 13 Montage du récipient à parfum de l humidificateur 11 Accrocher le poêle aux vis voir la figure 14 Fig 14 Fixer le poêle 12 Immobiliser le poêle au moyen de la vis de fixation voir la figure 15 Fig 12 Cotes 1 262 mm 10 31 po 2 270 mm 6 po 3 532 mm 16 3 po 4 206 mm 8 11 po 10 Coupelle à herbes humidificateur voir la figure 13 2 4 3 1 Fig 15 Vis de fixation du support 13 Installer le capteur...

Страница 23: ...er aux positions 8B 13 Éclairage bornier pour le raccordement de l éclairage 14 Contacteur de porte option 15 Interrupteur extérieur option 10 13 14 15 12 11 13 RJ10 4P4C 3 x 14 AWG RJ10 4P4C RJ10 4P4C ELITE PURE max 75 feet B G B 41 40 1 2 6 7 8 9 3 4 5 1A 2A 6A 7A 8A 9A 3A 4A 5A 120 V 14 AWG Max 6 Amp 5 3 8 3 kW 208 240 V 1B 2B 3B 4B 5B 6B 7B 8B SCHÉMA DE RACCORDEMENT BRANCHEMENT TAB 208 V monop...

Страница 24: ... ou raccordement constant possibles Interrupteur extérieur avec diode 2 A B 2 3 4 12 VDC 40mA max REMARQUE En cas de modification du câblage modulaire par exemple une réduction de la longueur d un câble une pince à sertir est nécessaire 1 2 3 4 Pin Pos 1A NTC Pin 1 Pin 2 NTC Pin 3 NTC Pin 4 Pos 2A Ext sw Pin 1 Pin 2 LED Pin 3 SW Pin 4 12 V Pos 6A 9A 4x RS485 Pin 1 A Pin 2 B Pin 3 12 V Pin 4 GND Po...

Страница 25: ...25 14 8 1 6 375mm 17 0 23 6 431mm 600mm 41mm 206mm 8 11 262mm 262mm 10 31 262mm 10 31 DIMENSIONS ...

Страница 26: ...utilisation du panneau de commande Consulter les instructions fournies avec le panneau de comman de Avant chaque utilisation Vérifier les points suivants S assurer que aucun objet qui n y a pas sa place ne se trouve dans la cabi ne sur le poêle ni à l intérieur de celui ci la porte et les éventuelles fenêtres de la cabine sont fermées la porte du sauna peut être ouverte vers l extérieur d une légèr...

Страница 27: ...voir à pierres 3 fois par an Pour contrôler l état du réservoir à pierres 1 Retirer toutes les pierres du réservoir 2 Éliminer tous les fragments de pierre graviers et concrétions de tartre 3 Remettre en place les pierres restées intactes et remplacer celles qui présentent des défauts Voir la section Remplir le réservoir à pierres page 13 Humidificateur DANGER Les essences parfumées etc peuvent s e...

Страница 28: ...ure baisse en dessous de 20º C 68 ºF sur le PCA Poêle La protection thermique dans le poêle sert empêcher la surchauffe du bois et des composants électroniques à l intérieur du sauna Sur le dessous du poêle se trouve un bouton pous soir rouge voir Fig 6 Si la protection thermique du poêle s est déclenchée un déclic est ressenti lorsqu on enfonce le bouton Si la protection thermique ne s est pas déc...

Страница 29: ...sformateur sur la carte PCB dans le poêle défectueux 6 Panneau de commande défectueux 1 Mettre le poêle sous tension au moyen de l interrupt eur principal 2 Vérifier et remplacer réinitialiser les fusibles dans le tableau principal 3 Mettre le poêle hors tension au moyen de l interrupt eur principal et connecter chaque câble paires de câbles au panneau de commande Mettre de nou veau le poêle sous t...

Страница 30: ...pour connaître le site de recyclage le plus proche ROHS RESTRICTION OF HAZARDOUS SUBSTANCES Instructions relatives à la protection de l environnement Cet appareil ne doit pas être mis au rebut avec des déchets mé nagers Après utilisation il devra être pris en charge par un site de recyclage des appareils électriques et électroniques Le symbole figurant sur le produit le manuel d utilisation ou l em...

Страница 31: ...194 F copper wire Don t forget to earth ground 120 V N 1 3 4 2 High Limit Control Heater AWG 14 Max 6 Amp 120 Volt Light input Separate from Heater Power Output to light SCHÉMA DE CÂBLAGE DU POÊLE ARRIÈRE MÉDIAN AVANT Interrupteur Circuit imprimé TERRE 208 240 V monophasé Sortie vers lampe Entrée lampe 120 Volt séparée de l alimenta tion du poêle Utiliser uniquement du fil de cuivre 90 C 194 F Ne p...

Отзывы: