2
When starting for the first time
Using the control panel for the first time:
1.
Check the heater manual for getting started and safety pre-
cautions.
2.
Pass your hand over the screen to light it up.
3.
Select region (
Europe
,
USA
,
Other
). Use
UP
and
DOWN
to
scroll through the menu. Confirm using
OK
(see
Figure 2,
Page 2).
Figure 2:
UP, DOWN and OK
4.
Select language. Confirm with
OK
.
5.
Enter current time. Confirm with
OK
.
6.
Enter current date (yyyy-mm-dd). Confirm with
OK
.
7.
Select
System type
(
Timer-controlled
,
Monitored
or
Private
).
Key to system type:
System type
Timer-controlled
is used for systems in which
calendar programming or delayed start are required. Maxim-
um running time for this choice is 12 hours. After 12 hours, the
system must be shut down for at least 6 hours. A door contact
must also be connected to the sauna door to detect whether
the door is opened after the last shut-down.
System type
Monitored
is used for systems where there are
always personnel to monitor the sauna. No calendar program-
ming or delayed start can be used with this choice.
System type
Private
is used for private systems. Max. sauna
time is 6 hours. Delayed start can be used with this choice,
but not calendar programming.
NOTE!
A door contact can be used for all system
types. The contact will detect if the sauna door is
opened after the last sauna has been taken. NB:
timer-controlled systems will require a check of the
sauna and confirmation on the control panel.
8.
Enter
Bathtime limit
(maximum time depends on system
type).
9.
Enter
Door contact
(
Yes
,
No
).
10.
Enter
Auto fill and empty
(automatic water filling and empty-
ing - applies to the Expression heater).
Start/stop
To start the heater:
1.
Pass your hand over the screen to light it up.
ON/OFF
is
marked (light intensity increases) (see
Figure 3,
Page 2).
Figure 3:
ON/OFF and ON/OFF STATUS
2.
If
ON/OFF
is not marked, use
UP
to scroll to the correct posi-
tion.
3.
Press
OK
.
ON/OFF STATUS
will light up in the
STATUS BAR
(see
Figure 1,
Page 1) to show that the sauna heater is
on.
When the heater is on, the temperature and time will be shown if
no other settings are changed.
To switch off, select
ON/OFF
and press
OK
.
NOTE!
When the heater is switched off or the set op-
erating time expires, it will switch into drying mode. The
heating element will run for 20 minutes to dry out the
sauna cabin. This can be deactivated by pressing
ON/
OFF
. When the heater is off, the control panel light will
go out. It is automatically activated when you pass your
hand over the panel. Tylö recommends using the drying
mode.
Setting temperature
To set sauna temperature:
1.
Select
TEMPERATURE
(see
Figure 4,
Page 2) and
press
OK
.
Figure 4:
TEMPERATURE
2.
Use
UP
and
DOWN
to set the temperature and confirm with
OK
.
At temperature settings over 70°C, sauna cabin heating will
be prioritised, and at temperature settings under 70 °C, steam
production will be prioritised. Prioritisation can be changed in
Settings
(see The section called
The SETTINGS menu
, Page
3).
Setting humidity level
To set humidity level:
1.
Select
HUMIDITY
(see ) and press
OK
.
Figure 5:
HUMIDITY/HUMIDITY STATUS for empty, half-full
and full reservoir.
2.
Set the desired humidity level on the scale of 0-10 (0 = dry
sauna and 10 = max. humidity). Confirm with
OK
.
Water level in the reservoir is indicated by
HUMIDITY STATUS
(see ) in the
STATUS BAR
(see
Figure 1,
Page 1, pos 6). An
illuminated, full drop symbol shows the reservoir is full. An illumin-
ated half-full symbol shows the reservoir is half full and a flash-
ing empty symbol shows the reservoir is empty. When starting, an
empty reservoir will also be indicated by a pulsating audio signal.
If the water runs out during your sauna, it will be indicated by a
pulsating audio signal and flashing symbol on the panel. When
filling with water,
HUMIDITY STATUS
will first change to half-full
and then to full, and a steady audio signal will indicate that the
reservoir is full.
Содержание H2
Страница 1: ...1205 ENGLISH USER AND INSTALLATION GUIDE H2 OK 29005140 ENG ...
Страница 12: ......
Страница 13: ...1205 SVENSKA BRUKS OCH MONTERINGSANVISNING H2 OK 29005140 SVE ...
Страница 24: ......
Страница 25: ...1205 РУССКИЙ ИНСТРУКЦИЯ ПО МОНТАЖУ И ЭКСПЛУАТАЦИИ H2 OK 29005140 RYS ...
Страница 36: ......
Страница 37: ...1205 DEUTSCH GEBRAUCHS UND MONTAGEANLEITUNG H2 OK 29005140 TYS ...
Страница 48: ......
Страница 49: ...1205 FRANÇAIS NOTICE DE MONTAGE ET D UTILISATION H2 OK 29005140 FRA ...
Страница 60: ......