PowerSeries Pro Installation Guide

Table 2-1 SIA quick reference

SIA Feature Programming Section

Comments

Range/Default

Requirement

Exit Time

[005]>[001], option 3

Access to Entry and Exit delays and Bell Time Out for the system.

Range:45- 255
seconds

Default: 60 sec.

Required

(programmable)

Exit Delay Restart

[018], option 7

Opening a Delay zone door after it has already been opened and closed during an
exit delay restarts the exit delay timer.

Default: Enabled

Required

Auto Stay Arm on Un-vacated Premises

[001]>[001]-[248] Zone type 05, 06,09

Function key: Forces the system to arm in Stay mode if the occupant does not exit
the premises after pressing the Away function key.

If no exit after full arm

Default: Enabled

Required

Exit Time and Progress Annunciation/Disable
or Remote Arming

[861]>[001]-[005], option 4

System times and audible exit beeps can be disabled when using the wireless key to
stay arm the system. When away arming, audible exit beeps can not be disabled.

For remote arming (using keyfob), it is possible to program the instant stay arm (no
exit delay). By default this option is OFF.

When arming/disarming with keyfob the bell squawk option shall be enabled.

The Bell shall be tested daily. Alternate option is to have bell squawk enabled for
arming/disarming

Default: Enabled

Allowed

Entry delay(s)

[005]>[001]-[008], options 1 and 2

Access to entry and exit delays and bell time out for the system

Note: Combined entry delay and communications delay (abort window) shall not
exceed 60s.

Range: 30 sec. to 4
min.

Default: 30 sec.

Required

(programmable)

Abort Window for Non-Fire zones

[002]>[001]-[248], option 7 ON

Access to zone attributes, i.e., swinger shutdown, transmission delay and cross zone.
May be disabled by zone or zone type.

Default: Enabled

Required

Abort Window Time - for Non-Fire zones

[377]>[002], option 1

Access to the programmable delay before communicating alarms

Note: Combined entry delay and communications delay (abort window) shall not
exceed 60 seconds.

Range: 00 - 45 sec.

Default: 30 sees

Required

(programmable)

Abort Annunciation

An audible tone is generated when an alarm is aborted during the abort window.

Hard-coded ON

Required

Duress Feature

[*][5]> master code> user 2-95> 5> 2

When this feature is enabled, selected user codes send a duress reporting code to the
central station when used to perform any function on the system. Section [019],
option [6] must be enabled.

Default: N

Required

Cancel Window

[377]>[002], option 6

Access to the communications cancel window. Minimum duration must be 5
minutes.

Range: 005-255

Default: 005

Cancel Annunciation

[308]>[001], option 8

Access to the reporting code for Alarm Canceled.

A Cancel was
transmitted

Default: Enabled

Required

Cross Zoning

[042]>Selection 3, option 002

Enables cross zoning for entire system. Zones can be enabled for cross zoning via
zone attribute option 8 in sections [002][101] - [248].

Programming required

Default: Disabled

Required

Burglary Verification Timer

[005]>[000], option 3

Access to the programmable Cross Zone timer.

Range: 000-255 sec.

Default: 60 seconds

Allowed

Swinger Shutdown for Alarms

[377]>[001], option 1

Access to the swinger shutdown limit for zone alarms.

For all non-fire zones, shut down at 1 to 6 trips.

Default: 2 trips

Required

(programmable)

Swinger Shutdown Enable

[002]>[001] - [248], option 6 ON

Access to swinger shutdown, transmission delay and cross zone attributes. Zone
attribute option 6 (Swinger Shutdown enabled) is ON.

Non-police response
zones

Default: Enabled

Allowed

24-Hr. Auto-verified Fire

[001]>[001]-[248], Zone type 025 ON

Access to 24-Hr. Auto-verified Fire.

Activates if Not restored within the specified time.

Must choose zone type
for application

Required

Call Waiting Cancel

[382], option 4 OFF

Access to the dialing sequence used to disable call waiting. Call waiting string can
be programmed in [304].

Depends on user
phone line

Default: Disabled

Required

System Test:

[*][6] Master Code, option 04

The system activates all keypad sounders, bells or sirens for 2 seconds and all
keypad lights turn on. Refer to user manual.

Walk Test Mode:

[*][8][Installer code][901]

This mode is used to test each zone on the system for proper functionality.

Walk Test Communications

[382], option 2

Enables communication of zone alarms while walk test is active.

Default: Disabled

Walk Test Start/ End Reporting Codes

[308][401], options 1 and 2

Access to the reporting codes for walk test start and end times.

Duress Code

Duress codes function the same as user access codes, except they transmit a duress reporting code when used to perform any
function on the system. Duress codes cannot be used to access [*][5], [*][6] or [*][8] menus.

Duress codes are created by the master user or supervisor users

- 32 -

Содержание PowerSeries Pro HS3032

Страница 1: ...10xLRSTUL y A B or C A ULC listed models B UL listed models C European and Australian models 4 wire smoke detectors FSA 410xUL FSA 410xTUL FSA 410xSUL FSA 410xSTUL FSA 410xLSTUL FSA 410xRUL FSA 410xRT...

Страница 2: ...nnect device If the neutral wire cannot be identified then this equipment must be connected to a mains source that comes from a disconnect device that simultaneously disconnects both poles Line and Ne...

Страница 3: ...instructions provided with the module 9 Wire the tamper switch into any available zone Configure the tamper for normally closed NC supervision Zone must be programmed for 24 hour latching or non latch...

Страница 4: ...owing terminals are available on the PowerSeries Pro alarm controller Table 1 2 Terminal descriptions Terminal Description BAT BAT Battery terminals Use to provide backup power during a power outage a...

Страница 5: ...A continuous rating 2 A short term Available only with standby battery connected DO NOT exceed the 700 mA load for UL ULC or EN certified applications HSM3350 AUX1 AUX2 3 A Subtract the listed rating...

Страница 6: ...erride the option in 013 Observe the following guidelines when wiring zones l For UL listed installations use SEOL or DEOL only l Minimum 22 AWG wire maximum 18 AWG l Do not use shielded wire l Do not...

Страница 7: ...otion detectors To configure TEOL supervision per zone use programming section 002 bit 15 Figure 1 10 TEOL wiring Note Resistor values are configurable in section 004 Bell wiring These terminals suppl...

Страница 8: ...ted on the sticker attached to the device The format is XXX YYYY where l XXX identifies the type or model of the device l YYYY is a short encrypted ID used by the system to identify the specific devic...

Страница 9: ...l To assign a keypad to a partition key in 01 08 for partition 1 8 3 Press the key and repeat step 2 for next keypad When finished programming all keypads press the key twice to exit programming Users...

Страница 10: ...resent on the system Note When additional information is available for a specific trouble condition a is displayed Press the key to view the additional information 2 Trouble Display This feature is us...

Страница 11: ...A temperature sensor falls below the low temperature warning threshold 11 Probe Disconn The probe on the flood detector or the temperature detector is disconnected 12 Fire Trouble A smoke sensor is i...

Страница 12: ...915 MHz North America 433 MHz Europe and 912 919 MHz international Access Codes l Up to 1003 access codes 1000 level 2 EN one installer code level 3 EN one maintenance code and one guard code l Progr...

Страница 13: ...ies with TS203 021 1 2 3 Telecom equipment require ments and EN50136 1 EN50136 2 ATS SP3 DP2 when used in conjunction with Ethernet and or Cellular paths l The integral Ethernet communication port and...

Страница 14: ...0 24 Hour Non Latching Tamper 061 24 Hour Masking 066 Momentary Keyswitch Arm 067 Maintained Keyswitch Arm 068 Momentary Keyswitch Disarm 069 Maintained Keywsitch Disarm 071 Doorbell Zone 072 Push to...

Страница 15: ...larm 05 Panic Alarm 06 Burglary Alarm 07 Medical Alarm 08 Supervisory 09 Priority Event 10 Holdup 11 Duress 12 Emergency 13 Fire Supervisory 14 Fire Trouble 15 CO Alarm 157 System Tamper 01 True Outpu...

Страница 16: ...tition 1 2 Partition 2 3 Partition 3 4 Partition 4 5 Partition 5 6 Partition 6 7 Partition 7 8 Partition 8 201 208 Partition 1 8 Zone Assignment 001 Zone 1 8 002 Zn 9 16 003 Zn 17 24 004 Zn 25 32 005...

Страница 17: ...eiver 3 06 Alt Comm Receiver 3 Restore 07 Alt Comm Receiver 4 08 Alt Comm Receiver 4 Restore 355 Alternate Communicator 5 01 Alt Comm Receiver 1 Supervision Failure 02 Alt Comm Receiver 1 Supervision...

Страница 18: ...iday 07 Saturday 404 Interval 4 Holiday Assignment 09 Holiday 1 10 Holiday 2 11 Holiday 3 12 Holiday 4 711 714 Holiday Group 1 4 001 099 Holiday Group 1 4 Date 1 99 000000 MMDDYY Audio Station Program...

Страница 19: ...Arming and Disarming Notifications 04 Trouble and Trouble Restore Notifications 05 Test Transmission Notifications 06 Reserved 07 Reserved 08 Reserved 693 Session 3 Notification Control 01 Alarm and A...

Страница 20: ...ODUCT installed b Storage Network Use The SOFTWARE PRODUCT may not be installed accessed displayed run shared or used concurrently on or from different computers including a workstation terminal or ot...

Страница 21: ...MSTANCES SHALL DSC BE LIABLE FOR ANY SPECIAL INCIDENTAL CONSEQUENTIAL OR INDIRECT DAMAGES BASED UPON BREACH OF WARRANTY BREACH OF CONTRACT NEGLIGENCE STRICT LIABILITY OR ANY OTHER LEGAL THEORY SUCH DA...

Страница 22: ...011 012 013 014 015 016 017 018 019 020 021 022 023 024 025 026 027 028 029 030 031 032 033 034 035 036 037 038 039 040 041 042 043 044 045 046 047 048 049 050 051 052 053 054 055 056 057 058 059 060...

Страница 23: ...11 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 1...

Страница 24: ...06 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 Module Record Module Type Slo...

Страница 25: ...PowerSeries Pro Installation Guide Installer Defined Access Codes 001 Installer Code 002 Master Code 003 Maintenance Code System Account Code 25...

Страница 26: ...in developing the escape plan 2 Study the possible escape routes from each location within the house Since many fires occur at night special attention should be given to the escape routes from sleepin...

Страница 27: ...rrupted service Equipment Maintenance Facility If trouble is experienced with this equipment HS3032 HS3128 HS3248 for repair or warranty information please contact the facility indicated below If the...

Страница 28: ...ty applications the integral Ethernet communicator or the plug in cellular modules Models LE9080 3G9080 or 3H9080 shall have the Encryption Key enabled AES128 bit encryption algorithm is validated und...

Страница 29: ...by the person operating the security system during the daily arming and disarming cycle Protection of the Control Unit The local control unit and the local power supply must be protected in one of the...

Страница 30: ...with HSM2HOST8 Wireless Transceiver mounted in the HSC3020CP plastic enclosure meets the requirements of Grade 2 Class II equipment as per EN50131 1 2006 A1 2009 A2 2017 Standards The model HS3032P H...

Страница 31: ...laration of conformity DoC for this product can be found at www dsc com under the Agency Listings section SIA False Alarm Reduction Installations Quick Reference Minimum required system consists of on...

Страница 32: ...elected user codes send a duress reporting code to the central station when used to perform any function on the system Section 019 option 6 must be enabled Default N Required Cancel Window 377 002 opt...

Страница 33: ...or damage shall be evaluated and a repair estimate shall be provided No repair work will be performed until a valid purchase order is received from the Customer and a Return Merchandise Authorization...

Страница 34: ...nt that all system users be trained in the correct operation of the alarm system and that they know how to respond when the system indicates an alarm Smoke Detectors Smoke detectors that are a part of...

Страница 35: ...or any kind of construction activity inside or outside the premises The testing should include all sensing devices keypads consoles alarm indicating devices and any other operational devices that are...

Страница 36: ...secution wherever necessary All trademarks not owned by Tyco are the property of their respective owners and are used with permission or allowed under applicable laws Product offerings and specificati...

Отзывы: