PowerSeries Pro Installation Guide
Trouble 12 – Not Networked Troubles:
[01]
Zone 001-248 Not Networked: Generated when a zone becomes out of sync with
the wireless network or has not been synchronized with the network after enrollment.
[02]
Keypad 01-16 Not Networked: Generated when a keypad becomes out of sync
with the wireless network or has not been synchronized with the network after
enrollment.
[03]
Siren 01-16 Not Networked: Generated when a siren becomes out of sync with
the wireless network or has not been synchronized with the network after enrollment.
[04]
Repeater 01-08 Not Networked: Generated when a repeater becomes out of sync
with the wireless network or has not been synchronized with the network after
enrollment.
[05]
User 01 - 1000 Not Networked: Generated when a wireless key becomes out of
sync with the wireless network or has not been synchronized with the network after
enrollment.
Trouble 13 – AUX Troubles
[05]
HSM2300: 1 A power supply AUX output voltage is out of range.
[06]
HSM2204: A high current AUX output module output voltage is out of range.
[07]
System Area: AUX output voltage is out of range.
[10]
HSM3408: The 8 zone expander AUX output voltage is out of range.
[11]
HSM3204CX: The corbus repeater AUX output voltage is out of range.
[12]
HSM3350 AUX 1 Trouble: 3 A power supply AUX output voltage is out of
range.
[13]
HSM3350 AUX 2 Trouble: 3 A power supply AUX output voltage is out of
range.
Trouble 14 – Limit exceeded troubles
[01]
Interactive zone: The number of zones configured in the panel is not supported by
ADC firmware (e.g:>220)
[02]
Interactive partition: The number of partitions configured is not supported by
ADC firmware (e.g:>8)
IMPORTANT!
Ensure you have the following information available before contacting
Customer Support :
l
Alarm controller type and version, (e.g., HS3032, 1.0):
Note:
Version number can be accessed by entering [*][Installer Code]
[900] on any keypad. This information is also located on a sticker on the
printed circuit board.
l
List of modules connected to control panel, (e.g., HSM2108,
HSM2HOSTx etc.).
Specifications
Zone Configuration
l
32, 128 or 248 wireless zones supported and up to 8 hardwired
zones available on the controller
l
41 zone types and 15 programmable zone attributes
l
Zone configurations available: normally closed, single EOL res-
istor, DEOL resistor, and TEOL resistor.
l
Hardwired zone expansion (fully supervised) available using the
model HSM2108 or HSM3408 (eight zone expander module)
l
Wireless zone expansion (fully supervised) available using the
HSM2Host 2-way wireless integration module operating at 915
MHz (North America), 433 MHz (Europe) and 912-919 MHz
(international)
Access Codes
l
Up to 1003 access codes: 1000 (level 2-EN), one installer code
(level 3-EN), one maintenance code, and one guard code.
l
Programmable attributes for each user code
l
Access codes are either 4, 6 or 8 digits in length, depending on the
setting of programming section [041]. Duplicate codes are not
valid.
Note:
For EN50131-1 Grade 2 compliant systems using 100 access codes
or less, 6 digit codes must be used. If using more than 100 access codes, 8
digit codes must be used. For EN50131-1 Grade 3 compliant systems 8
digit codes must be used.
Warning Device Output
l
2 remote, wireless indoor/outdoor warning devices supported:
models PGX901 (indoor), PGX911 (outdoor) (X=4, 8, or 9)
l
Programmable as steady, pulsed or temporal three (as per
ISO8201) and temporal four (CO alarm) output
l
Warning device sounds alarms in the following priority: fire, CO,
burg
Note:
For NFA2P certified systems the delay for operating the warning
device shall be set to max. 10 min.
Memory
l
CMOS EEPROM memory
l
Retains programming and system status on AC or battery failure
for 20 years min. (not verified by UL)
Power Supply - North America
l
Power Supply:HS65WPSNA (cord connected) and
HS65WPSNAS (hardwired, use in ULC Commercial Burg Secur-
ity Level IV and ULC Commercial Fire Monitoring applications)
l
Primary: 120 VAC, 60 Hz, Energy Efficiency Class VI
l
Secondary: 18 V DC, 3.6 A Limited Power Source (LPS)
l
Model HS65WPSNA mounted in the same enclosure or outside,
cord connected
l
Model HS65WPS mounted in the same enclosure, permanently
connected
Power Supply - International
l
Power Supply: HS65WPS
l
Primary: 100-240 V AC, 50 Hz, 1.7 A, Energy Efficiency Class
VI
l
Secondary: 18 Vdc, 3.6A, LPS
l
Mounted in the same enclosure, permanently connected
Note:
For installations using the power supply module mounted inside the
cabinet, replace fuse only with the same type (20 mm) rated New fuse
rating 250 V/3.15 A Slow Blow.
Regulated power supply:
l
3.6 A regulated, supervised
l
Type A as per EN50131-6 Standard
l
FET protected for Bell, Aux+ and Battery terminals
l
Reverse battery detection/protection
l
Supervision for input power and low battery
l
Normal and high current battery charge options
l
Supervised battery charging circuit
Current draw (control panel board assembly):
l
120 mA (nominal)
Bell Output:
l
Ratings:
l
UL/ULC applications: 10.8 V DC - 12.5 V DC
l
EN applications: 10 V DC - 14 V DC
l
700 mA supervised (1 k Ohm) bell output (current limited at 2
amps)
l
Steady, Pulsed, Temporal 3 fire, Temporal 4 CO alarm cadences
l
Bell open short circuit detection (so hardware)
Aux+:
l
Ratings:
l
UL/ULC applications: 10.8 V DC - 12.5 V DC
l
EN applications: 10 V DC - 14 V DC
l
Current = 2 A (shared with Corbus R(ed) and PGM outputs)
- 12 -