Safety Information
IMPORTANT
The equipment is fixed, wall-mounted and shall be installed in the position specified in these instructions. The equipment enclosure
must be fully assembled and closed, with all the necessary screws/tabs and secured to a wall before operation. Internal wiring must be
routed in a manner that prevents:
- Excessive strain on wire and on terminal connections
- Loosening of terminal; connections
- Damage of conductor insulation
WARNING:
Never
install
this
equipment
during
a
lightning
storm!
Instruct
the
end-user
to:
-
Not
attempt
to
service
this
product.
Opening
or
removing
covers
may
expose
the
user
to
dangerous
voltages
or
other
risks.
Any
ser-
vicing
shall
be
referred
to
trained
service
persons
only.
-
Use
authorized
accessories
only
with
this
equipment.
Do
not
dispose
of
the
battery
in
fire
or
water.
Disposing
of
the
battery
in
a
fire
will
cause
rupture
and
explosion.
Do
not
dispose
of
the
waste
battery
as
unsorted
municipal
waste.
Consult
your
local
regulations
and
/or
laws
regarding
recycling
with
regard
to
this
lead-acid
battery.
Doing
so
will
help
protect
the
environment.
Some
of
the
materials
that
are
found
within
the
battery
could
become
toxic
if
not
disposed
of
properly
and
may
affect
the
environment.
This
equipment,
LE4000,
is
fixed
and
shall
be
installed
by
Service
Persons
only
(Service
Person
is
defined
as
a
person
having
the
appropriate
technical
training
and
experience
necessary
to
be
aware
of
hazards
to
which
that
person
may
be
exposed
in
performing
a
task,
and
of
measures
available
to
minimize
the
risks
to
that
person
or
other
persons).
It
shall
be
installed
and
used
within
an
envir-
onment
that
provides
the
pollution
degree
max
2,
over
voltages
category
II,
in
non-hazardous,
indoor
locations
only.
This
manual
shall
be
used
with
the
Installation
Manual
of
the
relevant
alarm
control
panel.
All
instructions
specified
within
that
manual
must
be
observed.
Approvals
Information
For
UL
Residential
Fire
and
Burglary
installations,
the
LE4000
is
listed
as
a
sole
means
of
communication
or
as
a
back
up
when
used
in
conjunction
with
a
POTS
line
(dialer).
For
UL
Residential
Fire
installations,
the
LE4000
must
be
connected
to
a
UL-listed
power
supply
with
a
minimum
of
24
hours
standby
power
or
powered
using
the
ADP1310
(
W
)
-NAU
and
a
2200mAh
battery.
For
UL
Commercial
Burglary
installations,
the
LE4000
is
listed
as
a
sole
means
of
communication
(supervision
window
of
200s
required
at
monitoring
station)
or
as
a
back-up
when
used
in
conjunction
with
a
POTS
line
(dialer).
The
LE4000
shall
be
powered
from
any
compatible
listed
control
unit
or
compatible
listed
power
supply
that
complies
with
the
ratings
specified
on
page
1.
The
power
supply
shall
be
listed
for
burglary
applications
and
provide
a
minimum
of
4
hours
standby
power
cap-
abilities.
An
example
of
a
suitable
listed
compatible
control
unit
is
the
DSC
Model
PC1864
with
an
AUX
output
rated
11.1
-
12.6Vdc.
An
example
of
a
suitable
Listed
power
supply
is
DSC
Model
PC5204
with
an
AUX
output
rated
11.6
-
12.6Vdc.
For
ULC
Commercial
Burglary
installations
the
LE4000
is
listed
as
a
passive
communication
system
with
communication
line
secur-
ity
level
P1
when
used
as
single
communication
path
or
P2
when
used
as
a
back
up
in
conjunction
with
a
POTS
line
(dialer).
The
LE4000
is
also
listed
for
Active
line
security
levels
A1-A4
(90
seconds
heartbeat
enabled
and
supervision
window
of
180s
required
at
monitoring
station
receiver).
For
ULC
Commercial
Burg
installations,
the
LE4000
must
be
connected
to
a
ULC-listed
power
supply
with
a
minimum
of
24
hours
standby
power
or
powered
using
the
ADP1310
(
W
)
-NA
and
a
2200mAh
battery.
The LE4000
can be used in commercial burglary applications up to Security Level IV.
For
ULC
Residential
Fire
and
Burglary
installations
the
LE4000
is
listed
as
a
sole
means
of
communication
or
as
a
back
up
when
used
in
conjunction
with
a
POTS
line
(dialer).
For
ULC
Residential
Fire
installations,
the
LE4000
must
be
connected
to
a
ULC-
listed
power
supply
with
a
minimum
of
24
hours
standby
power
or
powered
using
the
ADP1310
(
W
)
-NA
and
a
2200mAh
battery.