TYAN B5538Y292X4-080PV4HR-BDW Скачать руководство пользователя страница 69

 

http://www.tyan.com 

 

69

Chapter 4: Motherboard Information

 

 

4.1   Board Image

 

 

 

 

 

This picture is representative of the latest board revision available at the time of 
publishing. The board you receive may not look exactly like the above picture. 

Содержание B5538Y292X4-080PV4HR-BDW

Страница 1: ...1 http www tyan com YR292 B5538 X4 Service Engineer s Manual...

Страница 2: ...2 http www tyan com...

Страница 3: ...ing liability or warranties relating to fitness for a particular purpose or merchantability MITAC retains the right to make changes to produce descriptions and or specifications at any time without no...

Страница 4: ...es These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radi...

Страница 5: ...Do not puncture mutilate or dispose of battery in fire There will be danger of explosion if battery is incorrectly replaced Replace only with the same or equivalent type recommended by manufacturer D...

Страница 6: ...nents gives a table of key components and provides block diagram of the system Chapter 2 Covers procedures on installing the CPU memory modules and hard drives Chapter 3 Covers removal and replacement...

Страница 7: ...t the purpose of this pin If your outlet does not support this kind of plug contact your electrician to replace your obsolete outlet Do not place anything on the power cord Place the power cord where...

Страница 8: ...mbols on Equipment Caution This symbol indicates a potential hazard The potential for injury exists if cautions are not observed Consult equipment documentation for specific details Warning This symbo...

Страница 9: ...nees bent Equipment Racks To avoid injury or damage to the equipment Observe local occupational health and safety requirements and guidelines for manual materials handling Do not attempt to move a rac...

Страница 10: ...install the Model in a rack do not place equipment on top of the unit It will cause restricted airflow and might cause damage to the equipment Make sure the product is properly matted with the rails P...

Страница 11: ...60 C 140 F The system battery is not replaceable If the battery is replaced by an incorrect type there is danger of explosion Replace the battery only with a spare designated for your product Do not a...

Страница 12: ...that could bridge live parts Use gloves when you remove or replace system components they can become hot to the touch If the product sustains damage requiring service disconnect the product from the...

Страница 13: ...13 http www tyan com...

Страница 14: ...PU and Heatsink 34 2 1 3 Installing the Memory 37 2 2 Rack Mounting 40 2 2 1 Installing the Server in a Rack 40 2 2 2 Installing the inner Rails to the Chassis 41 2 2 3 Installing the Outer Rails to t...

Страница 15: ...85 5 5 1 Manual Bars 86 5 6 BIOS Advanced Menu 87 5 6 1 PCI Subsystem Settings 89 5 6 2 ACPI Setting 92 5 6 3 Trusted Computing 93 5 6 4 CPU Configuration 94 5 6 5 SATA Configuration 97 5 6 6 USB Conf...

Страница 16: ...16 http www tyan com Appendix IV Technical Support 141...

Страница 17: ...X4 server system is capable of offering scalable 32 and 64 bit computing high bandwidth memory design and lightning fast PCI E bus implementation The YR292 B5538 X4 not only empowers your company in n...

Страница 18: ...2 5 Hot Swap 4 Internal Drive Bay per blade Supported HDD Interface SATA III 6 0Gb s System Cooling Configuration per blade FAN 3 4cm fans Processor per blade Supported CPU Series Intel Xeon E3 1200...

Страница 19: ...ard management controller BMC Supports storage over IP and remote platform flash USB 2 0 virtual hub AST2300 iKVM Feature 24 bit high quality video compression Dual 10 100 Mb s MAC interfaces BIOS per...

Страница 20: ...nt Yes Package Contains Barebone 1 YR292 B5538 Barebone Manual 1 Quick Installation Guide Installation CD 1 TYAN installation CD 1 3 Product Model Model HDD Bays Power supply YR292 B5538 X4 four nodes...

Страница 21: ...ld arrive packaged as illustrated below 1 4 1 Box Contents Per Node Component Description 2U chassis 4 nodes 4 hot swap HDD bays per node TYAN S5538 system board pre installed 2 800Watts single Power...

Страница 22: ...TYAN s website for service http www tyan com The web site also provides information of other TYAN products as well as FAQs compatibility lists BIOS settings etc TYAN Motherboard Drive CD 1 Heatsink p...

Страница 23: ...avior Power ID Power On Green Solid On ID active Blue Solid On IPMI System Normal Amber Off System Alert Amber Solid On LAN1 Active Green Blinking Link Green Solid On LAN2 Active Green Blinking Link G...

Страница 24: ...Amber solid on NOTE If you have checked and cleared the Status 2 and the IPMI LED continues to show amber solid on please refer to the Web UI to view the Event Log for possible solutions NOTE Node 1...

Страница 25: ...D Color Green Status LED Color Red No driver present or power disconnected OFF OFF Driver Present No Activity Solid ON OFF Access Activity Blinking OFF HDD Fail Don t care Solid ON Identifying Don t c...

Страница 26: ...t panel and the blue ID LED on the rear panel will light up The technical personnel can easily locate the system on the rack disconnect cables from the system and remove it from the rack for later rep...

Страница 27: ...reen 10Mb 100Mb 1000Mb activity Disabled Flash Green No LAN linked RJ 45 Linkage Right On Amber 1000Mb linked On Green 100Mb linked Disabled Off 10Mb mode or No LAN linked NOTE Left and Right are view...

Страница 28: ...28 http www tyan com 1 5 3 Internal View Per Node Number Description 1 HDD Cage 2 SATA HDD Backplane Board 3 System Fans 4 Power Distribution Board 5 CPU Socket 6 Memory 7 PCI E Riser Card Assembly...

Страница 29: ...d proper tools can prevent you from accidentally damaging the internal components 2 0 3 Tools The following procedures require only a few tools including the following A cross head Phillips screwdrive...

Страница 30: ...f any other grounded appliance Avoid touching motherboard components IC chips connectors memory modules and leads The motherboard is pre installed in the system When removing the motherboard always pl...

Страница 31: ...d on cards 2 1 1 Installing Hard Drives The YR292 B5538 X4 supports 4 2 5 hard drives per node Follow these instructions to install a hard drive Warning Always install the hard disk drive to the chass...

Страница 32: ...http www tyan com 32 3 Slide the HDD tray out 4 Unscrew the HDD tray bracket 5 Place a hard drive into the drive tray Use four screws to secure the HDD...

Страница 33: ...http www tyan com 33 6 Reinsert the HDD tray into the chassis 7 Press the locking lever to secure the tray Repeat the same procedures to install other HDD trays...

Страница 34: ...www tyan com 34 2 1 2 Installing the CPU and Heatsink Follow the steps below to install the processor and heatsink 1 Take off the CPU Socket protection cap 2 Pull the CPU lever up to unlock the CPU so...

Страница 35: ...om 35 3 Open the socket to a fully open position 4 Place the CPU in the CPU socket Make sure the gold arrow is located in the right direction 5 Close the socket and press the CPU socket lever down to...

Страница 36: ...http www tyan com 36 6 Place the heatsink on top of the CPU and secure it with 4 screws...

Страница 37: ...odules onto the motherboard 1 Press the memory slot locking levers in the direction of the arrows as shown in the following illustration 2 Align the memory module with the slot When inserted properly...

Страница 38: ...http www tyan com 38 Recommended Memory Population Table Quantity of memory installed Single CPU Installed DIMM_A0 DIMM_A1 DIMM_B0 DIMM_B1...

Страница 39: ...4GB DIMMs 32GB 4x 8GB DIMMs NOTE 1 Support DIMM type Unbuffered DDR3 ECC 2 No support for RDIMMs and SODIMM Ranks per DIMM DIMM Slots Per Channel DIMM Speed Support Voltage Single Rank UDIMM 1DPC 133...

Страница 40: ...ity A Sliding rails 2 B Screw kit 1 2 2 1 Installing the Server in a Rack Follow these instructions to mount the TYAN YR292 B5538 X4 into an industry standard 19 rack NOTE Before mounting the TYAN YR2...

Страница 41: ...n com 2 2 2 Installing the inner Rails to the Chassis 1 Draw out the inner rails from the rail assembly Install inner rails to the left and right side of chassis 2 Push the rails forwards to lock the...

Страница 42: ...ackets in the rack 2 Secure the outer rail to the rack using 4 M5 screws and 4 washers 2 sets front 2 sets rear for each side Secure the rails to the rack as shown 3 Repeat Step 2 if you want to insta...

Страница 43: ...http www tyan com 2 2 4 Rack mounting the Server To install the chassis to the rack 1 Lift the chassis and then insert the inner slide rails into the outside rails 2 Push the chassis back into the ra...

Страница 44: ...44 http www tyan com 3 Screw the chassis to the rack...

Страница 45: ...ck 1 Unscrew the chassis 2 Press the locking tabs on both sides of the chassis to pull the chassis out NOTE To avoid injury it is strongly recommended that two people lift the TYAN YR292 B5538 X4 into...

Страница 46: ...http www tyan com 46 NOTE...

Страница 47: ...pre installed components including the Motherboard front panel board SATA HDD board M2087 R PCI E Riser card System fans and Power supply unit etc 3 2 Disassembly Flowchart The following flowchart out...

Страница 48: ...the system PSU status 2 It is not recommended to plug out all four Compute Nodes at the same time during maintenance If possible please finish it within 5 minutes at room temperature 25 o C If the ma...

Страница 49: ...Follow Chapter 2 1 1 to pull the node out 3 3 1 Replacing Expansion Card The YR292 B5538 X4 has one preinstalled M7018_R16 1L riser card Follow the instructions below to disassemble the M7018 R16 1L...

Страница 50: ...the assembly Screw the riser card to the assembly and put it back in place 4 optional for M7018 R16 1L Unscrew to replace a new M7018 R16 1L card 5 Follow the procedures mentioned earlier in reverse...

Страница 51: ...3 2 Disconnecting All Motherboard Cables Before replacing the motherboard or certain components remove cables connected to the motherboard Follow these instructions to remove all motherboard cables 1...

Страница 52: ...bles follow the instructions below to remove the motherboard from the chassis 1 Remove the heatsink and processor if installed If there are any parts installed remove them as well 2 Remove the nine sc...

Страница 53: ...w these instructions to replace the Power Distribution Board 1 Disconnect the 20 pin power and PSMI cables from the power distribution board 2 Unscrew to take out the power distribution board 3 Repeat...

Страница 54: ...e Front Panel Board Follow these instructions to replace the Front Panel board 1 Release cables from the cable clip Unscrew the front panel tray 2 Pull the front panel tray from the chassis 3 Disconne...

Страница 55: ...4 Unscrew to take out the front panel board 5 Replace a new front panel board and screw it to the front panel tray 6 Repeat the procedures described earlier in reverse order to place the front panel...

Страница 56: ...cation LED 6 PW_LED FPB power LED 21 ID_SW Location Switch 7 WLED IPMI LED 22 FP5V_STBY 5VSB power 8 WLED IPMI LED 23 FPB_HDD_ACTIVITY_G HDD Green LED 9 SMBDAT I 2 C BUS Data 24 FPB_HDD_FAULT_R HDD Re...

Страница 57: ...eplacing the System Fan Follow these instructions to replace the cooling fans in your system 1 Disconnect the fan cables from the mainboard 2 Remove the screws that secure the fan to the system 3 Remo...

Страница 58: ...http www tyan com 58 4 Reinstall the fan s into the chassis following the procedures described earlier in reverse order...

Страница 59: ...tyan com To replace a fan unit 1 Remove the rubber screws from the fan 2 Use a flat head screw driver to push the screws open Replace a new fan and use the screw driver to push the screw back into the...

Страница 60: ...Backplane Board Follow these instructions to replace the SATA Backplane Board in your system 1 Disconnect one B4P PWR cable and five mini SAS cables from the backplane board 2 Unscrew the backplane br...

Страница 61: ...61 http www tyan com 4 Unscrew the backplane board from the bracket Replace a new SATA Backplane Board and reinstall it into the chassis following the above steps in reverse...

Страница 62: ...ane Board Features Front View Rear View Connector Description SATA0 J5 SATA1 J6 SATA2 J7 SATA3 J9 SATA Connector J1 J4 HDD Connector PW1 Power Connector JTAG CPLD Connector SGPIO J8 SGPIO Connector J1...

Страница 63: ...GND HDD Connector J1 J2 J3 J4 Pin NO Pin name Pin NO Pin name S1 GND P1 NC S2 SAS_TX P2 NC S3 SAS_TX P3 NC S4 GND P4 GND S5 SAS_RX P5 GND S6 SAS_RX P6 GND S7 GND P7 VDD_5_RUN S8 SAS_Present_L P8 VDD_5...

Страница 64: ...ption Pin No Net Name Description 1 CPLD_JTAG_TCK JTAC_TCK DataOut 6 NC 2 GND Ground 7 NC 3 CPLD_JTAG_TDO JTAC_TDO DataOut 8 NC 4 VDD_3P3_RUN 3 3V 9 CPLD_JTAG_TDI 5 CPLD_JTAG_TMS JTAC_TMS DataOut 10 G...

Страница 65: ...www tyan com 3 8 Replacing the Power Supply Replace the power supply unit 1 Press the latch down to pull the power supply out 2 After replacing a new power supply push the power supply back into the...

Страница 66: ...http www tyan com 66 Replace the power supply backplate boards 1 Press the latch down to pull the power supply out...

Страница 67: ...67 http www tyan com 2 Take out the power supply units 3 Unscrew the power supply backplate board M1501 BPB2 4 Disconnect the 24 pin power cable and the MB cable...

Страница 68: ...m 68 5 Unscrew the power supply backplate bracket 6 Take out the power supply backplate bracket 7 Unscrew to replace the M1501 BPB1 board 8 Repeat the procedures in reverse order to reinstall the powe...

Страница 69: ...m 69 Chapter 4 Motherboard Information 4 1 Board Image This picture is representative of the latest board revision available at the time of publishing The board you receive may not look exactly like t...

Страница 70: ...http www tyan com 70 4 2 Block Diagram S5538 Block Diagram NOTE NCSI 2 is optional...

Страница 71: ...of the latest board revision available at the time of publishing The board you receive may not look exactly like the above diagram But for the DIMM number please refer to the above placement for memor...

Страница 72: ...Module Header J21 24 SATA SGPIO Pin Header HBA J30 9 ME Firmware Update Jumper J25 25 7 pin Vertical SATA3 0 Connector SATA1 J23 10 BIOS Recovery Jumper J26 26 USB2 0 Header J27 11 Clear CMOS J28 27...

Страница 73: ...escriptor Security Override Pin Header Pin 1 2 Signal VCC3_AUX HDA_SD0 J18 Chassis Intrusion Header Open Pin 1 2 Signal INTRUSION GND Short Default Open to trigger the system chassis intrusion alarm S...

Страница 74: ...word or need to clear BIOS setting 2 Power off system and disconnect both power connectors from the motherboard 3 Put jumper cap back to Pin_1 and Pin_2 default setting 4 Use jumper cap to close Pin_2...

Страница 75: ...Connector Pin 1 2 3 4 Signal GND 12V NC NC Use this header to connect the cooling fan to your motherboard to keep the system stable and reliable J33 Front Panel Connector Signal Pin Pin Signal PWRLED...

Страница 76: ...TA1 SATA3 0 Connector 7 1 1 GND Connects to the Serial ATA ready drives via the Serial ATA cable SATA0 J24 SATA1 J23 SATA2 J20 SATA3 J19 SATA4 J15 SATA5 J14 2 SATA TX DP 3 SATA TX DN 4 GND 5 SATA RX D...

Страница 77: ...GND State Color Description On Blue System identified Off Off System not identified NOTE The ID LED can be activated remotely using IPMI Please visit the TYAN Web Site at http www tyan com to download...

Страница 78: ...touch this material Simply remove the protective cover and place the heat sink on the processor The second type of interface material is usually packaged separately It is commonly referred to as ther...

Страница 79: ...simply lay the motherboard inside the chassis and align the screw holes of the motherboard to the studs inside the case If there are any studs missing you will know right away since the motherboard w...

Страница 80: ...motherboard more securely in place Below is a chart detailing what the most common motherboard studs look like and how they should be installed Caution 1 To avoid damaging the motherboard and associat...

Страница 81: ...r exclusive use with the TYAN YR292 B5538 X4 barebones solution to provide power for the HDD backplane NOTE YOU MUST unplug the power supply before plugging the power cables to motherboard connectors...

Страница 82: ...http www tyan com 82 NOTE...

Страница 83: ...ettings and configurations of the BIOS are current at the time of print and are subject to change and therefore may not match exactly what is displayed on screen This section describes the BIOS setup...

Страница 84: ...st advice is to only alter settings that you thoroughly understand In particular do not change settings in the Chipset section unless you are absolutely sure of what you are doing The Chipset defaults...

Страница 85: ...ancy date and time of BIOS build and the version of BIOS Memory Information This displays the amount of system memory present on the system System Date Adjust the system date MM Months DD Days YYYY Ye...

Страница 86: ...Logs For record the system Event Logs Save Exit For selecting the exit options and loading default settings NOTE The Main BIOS Menu is the first screen that you can navigate which has two main frames...

Страница 87: ...ons for your system PCI Subsystem Settings PCI PCI X and PCI Express Settings ACPI Settings System ACPI Parameters Trusted Computing Trusted Computing Settings CPU Configuration CPU Configuration Para...

Страница 88: ...th Configuration Hardware health Configuration Parameters AST2300 Configuration System Super IO Chip Parameters Serial Port Console Redirection Serial Port Console Redirection Onboard Device Configura...

Страница 89: ...ed Single Root I O Virtualization Enable or disable Single Root I O Virtualization Enabled Disabled PCI Latency Timer Value to be programmed into PCI Latency Timer Register 32 PCI Bus Clocks 64 PCI Bu...

Страница 90: ...http www tyan com 90 PERR Generation Enables or Disables PCI Device to generate PERR Disabled Enabled SERR Generation Enables or Disables PCI Device to generate SERR Disabled Enabled...

Страница 91: ...http www tyan com 91 5 6 1 1 PCI Express Settings Automatic ASPM Automatically enable ASPM based on reported capabilities and known issues Disabled AUTO Force L0s...

Страница 92: ...g Enable ACPI Auto Configuration Enable or disable ACPI Auto Configuration Disabled Enabled Enable Hibernation Enable or disable System ability to Hibernate OS S4 Sleep State This option may not be ef...

Страница 93: ...m 93 5 6 3 Trusted Computing Security Device Support Enables or Disables BIOS support for security device O S will not show Security Device TCG EFI protocol and INTIA interface will not be available D...

Страница 94: ...Windows XP and Linux OS optimized for Hyper Threading Technology and disabled for other OS OS not optimized for Hyper Threading Technology When Disabled only one thread per enabled core is enabled Ena...

Страница 95: ...abled Hardware Prefetcher To turn on off the Mid Level Cache L2 streamer prefetcher Enabled Disabled Adjacent Cache Line Prefetch To turn on off prefetching of adjacent cache lines Enabled Disabled Bo...

Страница 96: ...U C7 Report Enable Disable CPU C7 Report to OS CPU C7s CPU C7 Disabled Package C State Limit Select Package C State Limit Auto C0 C1 C2 C3 C6 C7 C7s Intel TXT LT Support Enable Disable Intel TXT LT su...

Страница 97: ...abled SATA Mode Selection Determines how SATA controller s operate IDE AHCI RAID SATA Controller Speed Indicates the maximum speed the SATA controller can support Gen1 Gen2 Gen3 Serial ATA Port 0 1 2...

Страница 98: ...ATA eSATA Ports Support Disabled Enabled SATA Device Type Identify the SATA port is connected to Solid State Drive or Hard Disk Drive Hard Disk Driver Solid State Drive Spin Up Device On an edge detec...

Страница 99: ...ations Enabled Disabled Auto XHCI Hand off This is a workaround for OSes without XHCI hand off support The XHCI ownership change should be claimed by XHCI driver Enabled Disabled EHCI Hand off This is...

Страница 100: ...vice reset time out USB mass storage device Start Unit command time out 20 sec 10 sec 30 sec 40 sec Device power up delay Maximum time the device will take before it properly reports itself to the Hos...

Страница 101: ...ardware Health Configuration Auto Fan Control Auto Fan Control Help Select Disabled means the FAN Speed is running FULL ON Enabled Disabled BMC Alert Beep BMC Alert Beep On Off On Off PMBus Support PM...

Страница 102: ...http www tyan com 102 5 6 7 1 Sensor Data Register Monitoring Read only...

Страница 103: ...http www tyan com 103 5 6 8 AST2300 Configuration AST2300 Chip Read only...

Страница 104: ...disable Serial Port COM Enabled Disabled Device Settings Read only Change Settings Select an optimal setting for Super IO Device Auto IO 3F8h IRQ 4 IO 3F8h IRQ 3 4 5 6 7 9 10 11 12 IO 2F8h IRQ 3 4 5...

Страница 105: ...al Port for Out Of Band Management Windows Emergency Services EMS Console Redirection Console redirection enable or disable Disabled Enabled Console Redirection Settings The settings specify how the h...

Страница 106: ...xtends VT100 to support color function keys etc VT UTF8 Uses UTF8 encoding to map Unicode chars onto 1 or more bytes VT100 VT100 VT UTF8 ANSI Bits per Second Select serial port transmission speed The...

Страница 107: ...buffers are full a stop signal can be sent to stop the data flow Once the buffers are empty a start signal can be sent to restart the flow Hardware flow control uses two wires to send start stop sign...

Страница 108: ...r OS through a serial port COM1 COM2 Terminal Type VT UTF8 is the preferred terminal type for out of band management The next best choice is VT100 and then VT100 See above in Console Redirection Setti...

Страница 109: ...en sending data if the receiving buffers are full a stop signal can be sent to stop the data flow Once the buffers are empty a start signal can be sent to restart the flow Hardware flow control uses t...

Страница 110: ...N I350 Intel LAN I350 Enabled Disabled Onboard I350 LAN1 OPROM Intel LAN OPROM I350 Disabled PXE iSCSI Onboard I350 LAN2 OPROM Intel LAN OPROM I350 Disabled PXE LAN2 I210 Intel LAN I210 Enabled Disabl...

Страница 111: ...http www tyan com 111 5 7 Chipset Menu PCH IO Configuration PCH Parameters System Agent SA Configuration System Agent SA Parameters WatchDog Timer Configuration...

Страница 112: ...http www tyan com 112 5 7 1 PCH IO Configuration Restore AC Power Loss Specify what state to go to when power is re applied after a power failure G3 state Power Off Power On Last State...

Страница 113: ...1 USB Configuration EHCI1 Control the USB EHCI USB2 0 functions One EHCI controller must always be enabled Enabled Disabled EHCI2 Control the USB EHCI USB2 0 functions One EHCI controller must always...

Страница 114: ...ent SA Configuration VT d Check to enable VT d function on MCH Enabled Disabled Graphics Configuration Config Graphics Settings PEG Port Configuration Configure NB PCI Express Settings Memory Configur...

Страница 115: ...chable Gfx Auto IGFX PEG PCIE Primary PEG Select PEG0 PEG1 PEG2 PEG3 Graphics device should be Primary PEG Auto PEG11 PEG12 Primary PCIE Select PCIE0 PCIE1 PCIE2 PCIE3 PCIE4 PCIE5 PCIE6 PCI7 Graphics...

Страница 116: ...to Gen1 Gen2 Gen3 PEG1 Gen X Configure PEG1 B0 D1 F1 Gen1 Gen3 Auto Gen1 Gen2 Gen3 PEG2 Gen X Configure PEG2 B0 D1 F2 Gen1 Gen3 Auto Gen1 Gen2 Gen3 PEG0 ASPM Control ASPM support for the PEG Device Th...

Страница 117: ...Device This has no effect if PEG is not the currently active device Disabled Auto ASPM L0s ASPM L1 ASPM L0sL1 PEG2 ASPM Control ASPM support for the PEG Device This has no effect if PEG is not the cu...

Страница 118: ...http www tyan com 118 5 7 2 3 Memory Configuration Memory Information Read only Memory Frequency Limiter Maximum Memory Frequency Selections in Mhz Auto 1333 1600...

Страница 119: ...og Timer Configuration Watch Dog Mode Watch Dog Mode Help Disabled POST OS PowerON NOTE When Watch Dog Mode is set to Disabled the following item will not appear Watch Dog Timer Watch Dog Timer Help 2...

Страница 120: ...ivation key 65535 0xFFFF means indefinite waiting Bootup NumLock State Select the keyboard NumLock state On Off Quiet Boot Enable or disable Quiet Boot option Disabled Enabled Endless Boot Enable or d...

Страница 121: ...n event is detected the BIOS will display the event Disabled Enabled Wait for ESC If Error Wait for ESC key to be pressed if error occurs Enabled Disabled Boot Option 1 Set the system boot order Devic...

Страница 122: ...ing GA20 this option is useful when any RT code is executed above 1MB Upon Request Always Option ROM Messages Set display mode for Option ROM Force BIOS Keep Current INT19 Trap Response BIOS reaction...

Страница 123: ...OM policy Control the execution of UEFI and Legacy PXE OpROM Do not Launch UEFI only Legacy only Launch Storage OpROM policy Control the execution of UEFI and Legacy Storage OpROM Do not Launch UEFI o...

Страница 124: ...http www tyan com 124 Other PCI device ROM priority For PCI devices other than Network Mass storage or Video defines which OpROM to launch UEFI OpROM Legacy OpROM...

Страница 125: ...http www tyan com 125 5 8 3 Delete Boot Option Delete Boot Option Remove an EFI boot option from the boot order Select one to Delete Device Name...

Страница 126: ...he Create New Password window After you key in the password the Confirm New Password window will pop out to ask for confirmation User Password Set user password in the Create New Password window After...

Страница 127: ...http www tyan com 127 5 10 Server Mgmt Menu BMC Network Configuration Configure BMC network parameters...

Страница 128: ...iguration Configuration Address source Select to configure LAN channel parameters statically or dynamically by BIOS or BMC Unspecified option will not modify any BMC network parameters during BIOS pha...

Страница 129: ...http www tyan com 129 5 11 Event Logs Menu Change Smbios Event Log Settings Press Enter to change the Smbios Event Log configuration...

Страница 130: ...gs Erase Event Log Choose options for erasing Smbios Event Log Erasing is done prior to any logging activation during reset No Yes Next reset Yes Every reset When Log is Full Choose options for reacti...

Страница 131: ...anges Discard Changes and Exit Exit system setup without saving any changes Save Changes and Reset Reset the system after saving the changes Discard Changes and Reset Reset system setup without saving...

Страница 132: ...to any of the setup options Restore Defaults Restore Load Default values for all the setup options Save as User Defaults Save the changes done so far as User Defaults Restore User Defaults Restore th...

Страница 133: ...ation is also included for readers reference NOTE The red dots indicate the sensors Fan and Temp Sensor Location 1 Fan Sensor It is located in the third pin of the fan connector which detects the fan...

Страница 134: ...http www tyan com 134 BIOS Temp Sensor Name Explanation...

Страница 135: ...a MB_Air_Inlet Temperature of the M B Air Inlet Area NOTE If the DIMM slot is not populated the temp sensor will read N A CPU_DIMM_A0 Temperature of DIMM A0 Slot CPU_DIMM_A1 Temperature of DIMM A1 Slo...

Страница 136: ...http www tyan com 136 NOTE...

Страница 137: ...to S5538 MB Fan1 J49 Fan2 J50 Fan3 J51 2 SATA Cable SATA SAS Backplane BP Board to S5538 MB SATA SAS BP Board Connect to S5538 MB SATA Cable J5 SATA0 J24 J6 SATA1 J23 J7 SATA2 J20 J9 SATA3 J19 3 B4P P...

Страница 138: ...J1 J33 USB Cable J3 J27 5 2X10P PWR PSMI Cable PDB Board to S5538 MB PDB Board Connect to S5538 MB 2X10P PWR Cable PW1 Right blade J48 Left blade J41 PSMI Cable J3 Right blade J44 Left blade J45 6 2X1...

Страница 139: ...11T42800006 Power distribution board connect MB PBP 2 for YR292 Delta PSU RoHS Cable CCBL 033W 422T38600002 FRU TF CABLE KIT SBU B7008Y292X4 TCT MINI SAS CABLE 36P TO 7PX4 FOR YR292 B7008X4 700 750MM...

Страница 140: ...http www tyan com 140 NOTE...

Страница 141: ...es such as in depth Linux Online Support sections with downloadable Linux drivers and comprehensive compatibility reports for chassis memory and much more With all these convenient resources just a fe...

Страница 142: ...per maintenance of products Note A receipt or copy of your invoice marked with the date of purchase is required before any warranty service can be rendered You may obtain service by calling the manufa...

Отзывы: