GAS REGULATOR CHECK / CONVERSION
If the side burner is factory built for natural gas, the regulator supplied is set for 4” water column. The
regulator is convertible to 11” water column for system LP application.
Do not use with a 20-lb LP cylinder.
Make sure that the regulator is set for the correct gas type. To check, remove the brass hex cap. You will find
the conversion plastic pin attached to the cap to the underside of the cap. If the disc (1/2 in. diameter) of the pin
is close to the cap, then the regulator is set for natural gas. If the disc is at the tip of the pin, away from the brass
cap, the regulator is set for system LP application. To convert to natural gas, remove the plastic conversion pin
and invert and replace it back in a manner such that the disc is close to the brass cap. For both natural and LP,
the maximum inlet pressure is 14” water column.
WARNING:
•
DO NOT STORE SPARE LP-GAS CYCLINDER UNDER OR NEAR THIS
APPLIANCE.
•
NEVER FILL THE CYLINDER BEYOND 80 PERCENT FULL.
•
FAILURE TO DO SO MAY CAUSE FIRE, DEATH, OR SERIOUS INJURY
MAY OCCUR.
•
USE ONLY A 20-LBS (5 GALLON CAPACITY) GAS CYLINDER.
•
DO NOT USE A DENTED OR RUSTED LP CYLINDER.
•
NEVER USE A CYLINDER WITH A DAMAGED VALV.E
•
ALWAYS CHECK FOR LEAKSAFTER CHANGING THE LP CYLINDER.
•
THE LP PRESSURE REGULATOR AND HOSE SUPPLIED WITH THIS UNIT
MUST BE USED WITHOUT ALTERATION.