LIQUID PROPANE CONNECTION
Notice
All gas installations, conversions, and/or adjustments must be performed by an authorized service agent.
Notice
If your Breakfast Club is for Liquid Propane application, a factory supplied L.P regulator is set for
11” WC and is for use with L.P. gas only. The factory-supplied regulator and hose must be used with a 20
lb. L.P. cylinder. For plumb-in installation (system L.P. installation), the regulator must be changed and a
main gas shutoff valve must be installed. Contact your Twin Eagles dealer for a system L.P. regulator.
NOTE
: An enclosure for a propane gas cylinder shall be vented by openings on the level of the cylinder
valve and at floor level. The effectiveness of the opening(s) for purposes of ventilation shall be determined
with the propane gas supply cylinder in place. This shall be accomplished by one of the following:
a.
One side of the enclosure shall be completely open; or,
b.
For an enclosure having four sides, a top and a bottom:
1.
At least two ventilation openings at cylinder valve level shall be provided in the sidewall, equally
sized, spaced at 180 degrees (3.14 rad), and unobstructed. Each opening shall have a total free
area of not less than ½ square inch per pound (7.1cm²/kg) of stored fuel capacity and not less
than a total free area of 10 square inches (64 cm²).
2.
Ventilation opening(s) shall be provided at floor level and shall have total free area of not less
than ½ square inch per pound (7.1 cm²/kg) of stored fuel capacity and not less than a total free
area of 10 square inches (64.5 cm²). If ventilation openings shall be at floor level and are in a
sidewall, there shall be at least two openings. The bottom of the openings shall be at floor level
and the upper edge no more than 5 inches (127 mm) above the floor. The openings shall be
equally sized, spaced at 180 degrees (3.14 rad) and unobstructed.
c.
Every opening shall have minimum dimensions so as to permit the entrance of 1/8 inch (3.2 mm)
diameter rod.
! WARNING !
The gas supply hose should be inspected prior to each use. Do not use a gas hose that has abrasions, cuts,
or excessive wear.
The gas supply must be turned off at the LP Gas supply cylinder and the LP Gas supply cylinder
must be disconnected from the regulator when this outdoor cooking gas appliance is not in use.
When your Breakfast Club is stored indoors, remove and store the LP Gas cylinder outdoors in a
protected, cool, and dry location out of reach of children. The cylinder should not be stored in a building,