FABRICATOR 252i
INSTALLATION/SETUP
INSTALLATION/SETUP 3-2
Manual 0-5155
50/60 Hz
Single Phase
Primary Supply
Lead Size
Minimum
Primary Current
Circuit Size
(Vin/Iin)
Minimum
Plug Size
Current & Duty Cycle
MIG
LIFT TIG
STICK
Yes
10 AWG
208-230/50A
50A
40% @ 250A 40% @ 250A
40% @ 230A
Table 3-1: Input Power Source Leads for Fabricator 252i
WARNING
ELECTRIC SHOCK
can kill;
SIGNIFICANT DC VOLTAGE
is present after removal of input power.
DO NOT
TOUCH
live electrical parts.
SHUT DOWN
welding power source, disconnect input power employing lockout/tagging procedures. Lock-out/tagging
procedures consist of padlocking line disconnect switch in open position, removing fuses from fuse box, or shutting
OFF and red-tagging circuit breaker or other disconnecting device.
Electrical Input Requirements
Operate the welding power source from a single-phase 50/60 Hz, AC power source. The Welding Power Source must be:
• Correctly installed, if necessary, by a qualified electrician.
• Correctly earthed (electrically) in accordance with local regulations.
• Connected to the correct size power point, fuse and primary supply lead based on Table 3-1.
WARNING
Any electrical work must be carried out by a qualified Electrical Tradesperson.
3.05 Electromagnetic Compatibility
!
WARNING
Extra precautions for Electromagnetic Compatibility may be required when this Welding Power Source is
used in a domestic situation.
A. Installation and Use - Users Responsibility
The user is responsible for installing and using the welding equipment according to the manufacturer’s instructions.
If electromagnetic disturbances are detected then it shall be the responsibility of the user of the welding equipment to
resolve the situation with the technical assistance of the manufacturer. In some cases this remedial action may be as
simple as earthing the welding circuit, see NOTE below. In other cases it could involve constructing an electromagnetic
screen enclosing the Welding Power Source and the work, complete with associated input filters. In all cases,
electromagnetic disturbances shall be reduced to the point where they are no longer Troublesome.
NOTE
The welding circuit may or may not be earthed for safety reasons. Changing the earthing arrangements
should only be authorized by a person who is competent to assess whether the changes will increase the
risk of injury, e.g. by allowing parallel welding current return paths which may damage the earth circuits
of other equipment. Further guidance is given in IEC 60974-13 Arc Welding Equipment - Installation and
use (under preparation).
Содержание FABRICATOR 252i
Страница 6: ...This Page Intentionally Blank...
Страница 30: ...FABRICATOR 252i INTRODUCTION INTRODUCTION 2 6 Manual 0 5155 This Page Intentionally Blank...
Страница 88: ...FABRICATOR 252i PROBLEMS SERVICE PROBLEMS AND ROUTINE SERVICE 5 8 Manual 0 5155 This Page Intentionally Blank...
Страница 94: ...FABRICATOR 252i REPLACEMENT PARTS REPLACEMENT PARTS 6 6 Manual 0 5155 This Page Intentionally Blank...