C2-2450A O
PERATION
M
ANUAL
60
Number of logos
14F
Read only
Board temp. (deg.C)
0CD
Read only
Air temp. (deg.C)
148
Read only
Regulators temp.(deg.C)
147
Read only
PLD temp. (deg.C)
111
Read only
Fan speed (rpm)
0CE
Read only
Led brightness
12C
0..100
LCD backlight
200
0..1 = Off, On
Serial type
(See Specs to see if your
unit supports all options)
251
0 = RS-232
1 = RS-422
2 = RS-485
RS232 Baud rate
0AB
0..6 = 9600, 19200, 28800, 33600, 38400,
57600, 115200
TAC number 0
15D
Read only
TAC number 1
15E
Read only
TAC number 2
15F
Read only
TAC number 3
160
Read only
TAC number 4
161
Read only
TAC number 5
162
Read only
MAC number (IP port)
208
Read only – bytes reversed!
Not part of menu system
Front panel lock
0FC
0 = unlocked, 1 = locked
Emulate button press
24F
See section below.
Options installed or
attached – read only
264
24-bit number has a bit high to indicate that
a unit is attached, or an option installed:
Bit
Unit
Bit
Unit
0
Audio switcher
12
S2-110CV
1
S2-106AD
13
S2-110YC
2
S2-105PC
14
S1-101AA
3
S2-105PCA
15
Ethernet
4
S2-109PC
16
Tally / UMD module
5
S2-105CV
17
-
6
S2-105CVA
18
-
7
S2-105YC
19
-
8
S2-105YCA
20
-
9
-
21
-
10
S2-108HD
22
-
11
S2-105DVIA
23
-
11.4
Examples
Each example shows the packet sent to the unit and its response. When a byte is
not required to be sent it is indicated by a ‘- ‘in the table below (since a Read is 6
bytes shorter than a Write). Each character shown below is sent as a ASCII
character so F0400 is sent as ‘F’ ‘0’ ‘4’ ‘0’ ‘0’.
Packet sent
Packet returned