background image

15

 

TP9KF-TUX   

Mar 2019-A 

 

OPERATION INSTRUCTIONS 

 

RAISE LIFT 

1.  Read operating and safety manuals before using lift. 

2.  Always lift a vehicle according to the manufacturers recommended lifting points 

3.  Position vehicle between columns, as equally as possible. 

4.  Adjust swing arms so that the vehicle is positioned with the center of gravity midway between pads. 

5.  Use truck adapters as needed. Never exceed 9

” of pad height. 

6.  Raise the lift by pressing button on power unit until support pads contact the underside of the vehicle 

and re-check to make sure vehicle is secure. 

7.  Raise vehicle to desired working height. The latch mechanism will 

‘trip over’ when the lift raises and 

drop into each latch stop.   

8.  Press lowering 

‘release’ lever on Power Unit to lower lift onto latches, to lock the lift in the proper safety 

position. 

 

Note: Always lock the lift before going under the vehicle. Never allow anyone to go under the lift 

when raising or lowering. Read the safety procedures in the manual. 

 

 

LOWER LIFT 

1.  Ensure tools, trays, stands and/or personnel are removed from under vehicle. 

2.  Slightly raise lift until the safety latches clear column locks. 

3.  Pull latch release cables on both sides. 

 

  WARNING:

   

ALWAYS RELEASE BOTH SAFETY LATCHES ON EACH SIDE

 

 

4.  Press the release lever on the power unit to lower the lift. 

5.  Before removing vehicle from lift area, position lift arms and supports to provide an unobstructed exit. 

 

 

WARNING:

   

NEVER DRIVE OVER LIFT’S ARMS.

 

 

Note: It is normal for an empty lift to lower slowly, it may be necessary to add weight. 

 

 

 

 

 

Содержание TP9KF-TUX

Страница 1: ...Mar 2019 A TP9KF TUX Two Post Floor Plate Lift Symmetric 9 000 lbs Capacity 2 250 lbs Max per Arm INSTALLATION OPERATION MANUAL...

Страница 2: ...t only part of the vehicle Improper use of this equipment could result in damage to the lift yourself or other property The lift is intended to lift vehicles only It is not designed to lift any person...

Страница 3: ...Screwdriver Locking Needle Nose and Snap Ring Pliers GENERAL INFORMATION 1 Carefully remove the crating and packing materials CAUTION Be careful when cutting steel banding material as items may become...

Страница 4: ...TP9KF TUX Mar 2019 A...

Страница 5: ...Always use architects plans when available Check layout dimension against floor plan requirements making sure that adequate space is available Figs 2 3 4 Fig 2 Elevation Layout 2 OVERHEAD OBSTRUCTION...

Страница 6: ...TP9KF TUX Mar 2019 A Fig 3 Swing Arm Column Layout Fig 4 Column Floor Layout 134 5 8...

Страница 7: ...lifting arms swivel pads height extensions hardware box etc from the column Check the quantity of each item with the parts list If anything is missing please contact your dealer at once STEP 3 Site L...

Страница 8: ...if shimming is required that enough threads are left exposed 6 Using a level check column plumb for every side Fig 6 If shimming is required use supplied Shim stock or 3 4 washers placing shims as clo...

Страница 9: ...r unit is clean Suggestion Use Non Detergent Non Foaming Hydraulic Oil SAE 10 AW 32 or equivalent The unit holds approximately ten quarts of fluid Fig 9 STEP 7 Installing Routing EQUALIZER CABLES 1 Ra...

Страница 10: ...S Cont Cable Routing Diagram Fig 13 5 Repeat above for the second cable 6 Adjust each equalizer cable to approximately 1 2 side to side play Ensure that each cable has equal tension Check the carriage...

Страница 11: ...ight fitting on power unit Secure other hose end to the fitting at the base of the mainside column Tighten to secure Figs 14 15 d Install long hydraulic hose w curved ends between the columns to each...

Страница 12: ...ms Floor Plate Arm Restraints Continued 3 Install Arm Restraint mechanisms to each swing arm as detailed below Fig 17 4 Check for proper engagement for the arm restraints as the gear rack should fully...

Страница 13: ...Fig 18 IMPORTANT The wiring must comply with local code Protect each circuit with time delay fuse or circuit breaker For 208V 230V single phase use 20 amp fuse WARNING Never operate the motor in line...

Страница 14: ...hydraulic system 2 To lower the lift both carriage s safety latch releases must be manually pulled down to be released to lower lift Fig 20 The latches will automatically reset once the lift ascends a...

Страница 15: ...es and drop into each latch stop 8 Press lowering release lever on Power Unit to lower lift onto latches to lock the lift in the proper safety position Note Always lock the lift before going under the...

Страница 16: ...ocking Prior to lowering vehicle walk around the lift and check for any objects that might interfere with the operation of lift and safety latches tools air hoses shop equipment After lowering swing t...

Страница 17: ...d tighten anchors bolts nuts and screws Check wiring switches for damage Keep base plate free of dirt grease or any other corrosive substances Check floor for stress cracks near anchor bolts Check swi...

Страница 18: ...ds for deformation or damage Check cylinder mount for looseness and damage Relocating or changing components may cause problems Each component in the system must be compatible an undersized or restric...

Страница 19: ...lift B Bad capacitor call electrician C Low voltage call electrician D Faulty wiring call electrician 5 Lift jerks going up and down A Air in hydraulic system raise lift all the way to top and return...

Страница 20: ...TP9KF TUX Mar 2019 A POWER UNIT PRIMING WARNING Failure to properly relieve pressure in the following steps can cause injury to personnel...

Страница 21: ...TP9KF TUX Mar 2019 A EXPLODED VIEW 1...

Страница 22: ...TP9KF TUX Mar 2019 A EXPLODED VIEW 2...

Страница 23: ...Rod Arm Restraint 4 15 TP9KF TUX 015 GB91 86 Split Pin 4 16 TP9KF TUX 016 GB97 2 85 Flat Washer 4 17 TP9KF TUX 017 TPF4 200 11 02 Spring 4 18 TP9KF TUX 018 TPF4 200 11 04 Gear Bar Arm Restraint 4 19 T...

Страница 24: ...1 Hyd Hose Long 1 46 TP9KF TUX 046 TPF4 200 01 00 Carriage 2 47 TP9KF TUX 047 DL38G C109A Sliding Rub Block 16 48 TP9KF TUX 048 GB91 86 Split Pin 2 50 TP9KF TUX 050 TPF4 300 00 Lock Latch 2 51 TP9KF T...

Страница 25: ...nsidered a warranty issue and therefore must be noted for any potential recovery with the shipping company The customer is required to notify Tuxedo of any missing parts within 72 hours Timely notific...

Отзывы: