11
TP9KF‐TUX
Mar 2019‐A
STEP 8
:
(Installing / Routing HYDRAULIC HOSES & HYDRAULIC FITTINGS)
1.
Install & connect hydraulic hoses & fittings as noted & shown below in
(Figs. 14-16)
along with the
Exploded View #1 diagram on page 21.
Note: Ensure Not To Overtighten Hydraulic & Hose Fittings!!
a) Remove red cap plug from high pressure port on side of power unit
’s valve block.
b) Install & secure hydraulic straight fitting (w/ O-ring) to power unit
’s high pressure port.
(Fig. 14)
c) Install short hydraulic hose to the straight fitting on power unit. Secure other hose end to the
fitting at the base of the mainside column. Tighten to secure.
(Figs. 14 & 15)
d) Install long hydraulic hose (w/ curved ends) between the columns to each cylinder. Secure hose
ends to cylinder fittings located at the base of each column. Tighten to secure.
(Fig. 16)
Fig. 14 Fig. 15 Fig. 16
CAUTION! When routing the hydraulic hoses, make sure hoses & fittings are clear of any moving parts.
STEP 9
:
(Installing Swing Arms, Floor Plate & Arm Restraints)
1.
Install the
Swing Arms
on the carriages using the included 1-1/2
” swing arm pins, as shown below.
2.
Install
Drive-Over Floor Plate
between each column & secure to Base Plates with socket screws, as
shown below.