ACM 400 S motor control unit

 

4 / 24

 

Photoelectric  barrier  Short  circuit 
current 

I

LSin-0

 

 

5.0 

6.0 

mA 

Via terminals 31 / 30 

photoelectric barrier reaction time 

t

LS-1

 

 

65 

100 

ms 

LS command time until motor switched 

photoelectric barrier reset time 

t

LS-0

 

 

500 

800 

ms 

 

SE1-SE4 (8K2) not actuated 

R

SE12-0

 

6.2 

8.2 

10.3 

K  

For SE1-SE4 

SE1-SE4 (8K2) actuated 

R

SE12-1

 

11.0 

 

5.8 

K  

For SE1-SE4 

SE1-SE4 (OSE) level, release 

U

SE12OSE-0

 

0.9 

 

2.5 

At terminals 32, 34, 35 and 37 

SE1-SE4 (OSE) frequency 

f

SE12OSE-0

 

0.6 

 

1.8 

KHz 

At terminals 32, 34, 35 and 37 

SE1-SE4  reaction time 

t

SE12-1

 

 

50 

80 

ms 

At 8K2 or OSE 

SE1-SE4  reset time 

t

SE12-0

 

 

500 

700 

ms 

 

Universal not actuated (open) 

U

UNIV-0

 

4.0 

5.0 

 

At terminals 23/24 

Universal actuated (closed) 

U

UNIV-1

 

 

0.0 

1.0 

At terminals 23/24 

Universal actuated (closed) 

I

UNIV-1

 

 

8.0 

10.0 

mA 

 

Universal input resistance 

R

UNIVin

 

 

625 

 

Pull-Up from +5V 

Universal 

pulse 

duration 

(debounce) 

t

UNIV

 

 

50 

 

ms 

 

Pulse not actuated (open) 

U

IMP-0

 

4.0 

5.0 

 

At terminals 25/24 

Pulse actuated (closed) 

U

IMP-1

 

 

0.0 

1.0 

At terminals 25/24 

Pulse actuated (closed) 

I

IMP-1

 

 

8.0 

10.0 

mA 

 

Pulse input resistance 

R

IMP

 

 

625 

 

Pull-Up from +5V 

Pulse duration (debounce) 

t

IMP

 

 

50 

 

ms 

 

Open not actuated (open) 

U

AUF-0

 

4.0 

5.0 

 

At terminals 26/27 

Open actuated (closed) 

U

AUF-1

 

 

0.0 

1.0 

At terminals 26/27 

Open actuated (closed) 

I

AUF-1

 

 

8.0 

10.0 

mA 

 

Open input resistance 

R

AUFin

 

 

625 

 

Pull-Up from +5V 

Open Pulse duration (debounce) 

t

AUF

 

 

50 

 

ms 

 

Closed not actuated (open) 

U

ZU-0

 

4.0 

5.0 

 

At terminals 28/27 

Closed actuated (closed) 

U

ZU-1

 

 

0.0 

1.0 

At terminals 28/27 

Closed actuated (closed) 

I

ZU-1

 

 

8.0 

10.0 

mA 

 

Closed input resistance 

R

ZUin

 

 

625 

 

Pull-Up from +5V 

Closed 

Pulse 

duration 

(debounce) 

t

ZU

 

 

50 

 

ms 

 

Stop not actuated (open) 

U

Stop-0

 

4.0 

5.0 

 

An terminals 29 / 0V 

Stop actuated (closed) 

U

Stop-1

 

 

0.0 

1.0 

An terminals 29 / 0V 

Stop actuated (closed) 

I

Stop-1

 

 

8.0 

10.0 

mA 

 

Stop input resistance 

R

Stop

 

 

625 

 

Pull-Up von +5V 

Stop pulse duration (debounce) 

t

Stop

 

 

50 

 

ms 

 

Outputs 

 

 

 

 

 

 

Light output (230V

AC

P

Licht

 

 

 

500 

An terminals 9 / 10 

Warning light output (230V

AC

P

Warn

 

 

 

500 

An terminals 11 / 10 

Motor output 1~  230V 

P

Motor1~

 

 

 

1,0 

KW 

 

Motor output 3~ 400V 

P

Motor3~

 

 

 

2.2 

KW 

 

Motor running time 

t

Mot

 

 

 

120 

 

Motor operating time 

ED 

 

 

25 

At maximum motor output, max running time 

Universal2- switching capacity 

U

Univ2

 

 

 

275 

V

AC

 

 

Universal2- switching capacity 

P

Univ2

 

 

 

750 

VA 

Max. 3A 

Voltage 24V- output 

U

24V

 

22 

 

33 

V

AC

 

full load / idle mode at terminals 21 / 20 

Current 24V- output 

I

24V

 

 

200 

mA 

@ 2 plug-in card, full load, U

Netz

 = 195V 

Voltage 12V- output 

U

12V

 

10 

 

12 

V

DC

 

full load / idle mode an terminals 22 / 20 

Current 12V- output 

I

12V

 

 

100 

mA 

@ 2 plug-in card, full load, U

Netz

 = 195V 

Voltage 5V-output 

U

5V

 

4.8 

5.0 

5.2 

V

DC

 

An BL3, Pin 3 

Current 5V-output 

I

5V

 

 

20 

mA 

An BL3, Pin 3 

Ambient conditions 

 

 

 

 

 

 

Ambient temperature 

T

Umgeb

 

-20 

 

+50 

°C 

Outside the housing 

Operating temperature 

T

Betr

 

-20 

 

+70 

°C 

Inside the housing, normal installed position 

Storage temperature 

T

Lag

 

-25 

 

+80 

°C 

 

Relative air humidity 

RH 

20 

 

90 

No condensation permitted! 

Printed circuit board 

 

 

 

 

 

 

Controller frequency 

f

Cont

 

 

4.19 

 

MHz 

Internal PLL at 16.76MHz 

Length 

L

LP

 

 

218 

 

mm 

 

Width 

B

LP

  

 

166 

 

mm 

 

Height 

H

LP

 

 

55 

 

mm 

 

Weight  

m

LP

 

 

1030 

 

Without plug-in card and housing 

Housing  

 

 

 

 

 

 

Length 

L

Geh

 

 

255 

 

mm 

Without cable entry 

Width 

B

Geh

 

 

176 

 

mm 

 

Height 

H

Geh

 

 

78 

 

mm 

 

Weight 

m

Gesamt

 

 

1680 

 

housing  incl.  printed  circuit  board  and  self-sealing 
plug 

Material 

 

 

 

 

 

ABS, self-extinguishing 

Degree of protection 

 

 

 

 

 

IP65 

 

Содержание ACM 400 S

Страница 1: ...302_ACM400S_EN doc 1 24 ACM 400 S 1 motor 230V 400 gate control unit Assembly installation connection and programming instructions for the fitter Please keep these instructions in a safe place so you...

Страница 2: ...r sensors X7 11 m Method of connection for self test 11 n Speed sensor X7 11 o Photoelectric barrier X7 11 p Closing edge safety device X7 11 q Light outputs X10 12 r Universal output X12 13 s Radio r...

Страница 3: ...ta based on software status ACM400S V1 4 Parameter Symbol Limit values Units Test conditions Min Typical Max Power supply System voltage 1 230V UNetz1 205 230 255 VAC At terminals 5 8 System voltage 3...

Страница 4: ...put resistance RZUin 625 Pull Up from 5V Closed Pulse duration debounce tZU 50 ms Stop not actuated open UStop 0 4 0 5 0 V An terminals 29 0V Stop actuated closed UStop 1 0 0 1 0 V An terminals 29 0V...

Страница 5: ...s The end product manufacturer is thus responsible for compliance and declaration of CE conformity The control unit complies with the requirements in DIN EN 60204 EN 13241 1 EN 61000 6 2 EN60335 1 EN...

Страница 6: ...ating moisture X13 The weight of the control unit is approx 1 7 kg Please take this into account when choosing the type of fixing Install the control unit housing professionally at the suitable instal...

Страница 7: ...to terminals L1 3 N PE c 400V motor 3 X14 The load tap of the motor control unit and 3 phase operation is designed for a max motor output of 2000W 400V However a max operating time of 25 must not be...

Страница 8: ...0 Stop is a purely function input without safety function Gate status Open pressed Closed pressed Stop pressed standing in limit position Open closes standing in limit position Closed opens standing i...

Страница 9: ...Textmarke nicht definiert is also possible via the membrane keyboard i Universal input X8 1 With this you can realise both optional partial opening mode and Automatic closing Partial opening mode ena...

Страница 10: ...keep open time standing in partial opening position Automatically closes after expiry of the keep open time keep Open button pressed Stays open keep open time starts running again Closed button presse...

Страница 11: ...et via menu 0 X7 1 Connect the signal output to terminals 19 20 Gate status Reaction Standing running Menu 0 value 00 no sensor connected 01 Type Castalia connected If signal cannot be measured 0 5s a...

Страница 12: ...Stop 14 14 30 closes Release 15 15 31 closes opens Release if an obstruction is detected the gate moves a short distance in the opposite direction released Release time in 0 25s steps Menu B value 00...

Страница 13: ...the limit position Open along the gate s path and in the Closed limit position the signal light remains red for special functions to be switched on by radio button e g bell time switch or pulse for ga...

Страница 14: ...ive inputs outputs X6 1 At terminals 23 39 lit LEDs mean that the respective inputs have been triggered or are not closed off X6 2 At terminals 40 42 lit LEDs mean that the respective limit switch has...

Страница 15: ...t switch within 2s of starting Restart motor If error remains Gate won t move Check mechanics motor transmission emergency unlocking gate frozen Gate moves Check limit switch contact wiring or speed s...

Страница 16: ...u item appears in the display You can now use the keys to change the value as described on pages 8 16 The value is immediately adopted as soon as you set it d Reset You can reset the values to the fac...

Страница 17: ...control unit constantly performs various self tests If an error occurs the control unit is locked and an error message is displayed see table on page 15 Faulty self tests are automatically repeated a...

Страница 18: ...mergency operation In order to enable controlled movement of the gate when safety equipment closing edge safety device photoelectric barrier is continuously actuated e g in case of a defect in a safet...

Страница 19: ...pen Closed Pulse and Partial opening functions or the universal output a radio receiver can be installed in the Radio slot see page 13 X4 This is described in greater detail in the installation instru...

Страница 20: ...Stop Stop 22 OSE Stop Release 23 OSE Stop Reversing 24 OSE Release No effect 25 OSE Release Stop 26 OSE Release Release 27 OSE Release Reversing 28 OSE Reversing No effect 29 OSE Reversing Stop 30 OS...

Страница 21: ...g Stop while closing panic function 02 RADIO OPEN Stop while opening Stop while closing panic function RADIO CLOSED Reversing while opening no effect while closing 03 RADIO OPEN No effect while openin...

Страница 22: ...ACM 400 S motor control unit 22 24 13 Figures Diagrams X1 X5 X7 X8 X9 X4 X3 X2 X6...

Страница 23: ...ACM 400 S motor control unit 23 24 X10 X12 X13 X14 X17 X15 X18 X16 X19 X11...

Страница 24: ...ACM 400 S motor control unit 24 24 14 Block CIRCUIT DIAGRAM...

Отзывы: