19
6.2 START-UP CHECKLIST
We recommend that these startup procedures be followed in sequence and checked off ( ) in the
boxes provided in any of the following cases:
• During initial installation
• After any shutdown period
• After maintenance work has been performed
• After booster has been moved to a new location
DATES CHECKED:
Check the unit for proper lubrication. Proper oil level cannot be over-emphasized.
Refer to the
Lubrication
section. Please see
Recommended Lubricants
for information
on acceptable lubricants for your product.
Check V-belt drive for proper belt alignment and tension.
Carefully turn the rotors by hand to be certain they do not bind.
WARNING
Disconnect power. Make certain power is off and locked out before touching
any rotating element of the booster, motor, or drive components.
“Bump” the unit with the motor to check rotation (counter-clockwise [CCW] when
facing shaft) and to be certain it turns freely and smoothly.
Start the unit and operate it for 30 minutes at no load. During this time, feel the
cylinder for hot spots. If minor hot spots occur, refer to the
Troubleshooting
chart.
Apply the load and observe the operation of the unit for one hour.
If minor malfunctions occur, discontinue operation and refer to the
Troubleshooting
chart.
6.3 STARTING
Check the oil for proper level at both ends of the booster. Add or drain oil as necessary to bring the oil to
the correct level. See Figure 4. Too much oil, particularly on the gear end, can result in excessive heat
generation. Too little oil will possibly result in failure of the timing gears, bearings, and mechanical seals.
Start the backing pump. When pressure is reduced sufficiently, start booster pump. A pressure switch can
be installed to start the booster at a predetermined pressure. If the booster is water cooled turn on the
cooling water when the booster is started. Adjust the water flow so that the discharge water temperature is
no more than lukewarm (70° to 80° F [21° to 26° C]).
6.4 OPERATING TEMPERATURE
The upper temperature limits for booster pump operation are between 350° to 375° F (177° to 190° C)
measured in the exhaust gas stream with a low mass thermocouple. When this temperature limit switch
is installed, as the temperature exceeds the predetermined temperature, the booster motor will stop and
cannot be restarted until the temperature drops below the trip setting of the temperature switch.
DANGER
The booster is not intended to be used with explosive products or in explosive
environments. The booster is not intended to be used in applications that
include hazardous and toxic gases. Consult the factory for support.
Содержание M-D Pneumatics 7010
Страница 43: ...43 NOTES ...
Страница 50: ...50 3200C CUTAWAY DRAWING 3200 90C 91C 92C 93C 1 OF 2 A ...
Страница 51: ...51 3200C CONFIGURATIONS DRAWINGS 3200 90C 91C 92C 93C 2 of 2 A ...
Страница 54: ...54 5500C CUTAWAY DRAWING 5500 90C 91C 92C 93C 1 OF 2 E OIL LEVEL SIGHT GAUGE DETAIL ...
Страница 55: ...55 5500C CONFIGURATIONS DRAWINGS 5500 90C 91C 92C 93C 2 of 2 E ...
Страница 56: ...56 7000C CUTAWAY DRAWING 7000 90C 91C 1 OF 3 ...
Страница 57: ...57 7000C CONFIGURATIONS DRAWING 7000 90C 2 OF 3 ...
Страница 58: ...58 7000C CONFIGURATIONS DRAWING 7000 91C 3 OF 3 7000 91C 7013 SHOWN ...
Страница 68: ...68 NOTES ...