Manual 2017 Rev C p/n 2017
16
05
Installation
Most CP Series blowers are shipped from
the factory in a left hand drive, vertical
À
ow
con
¿
guration. If drive shaft location is changed,
the oil level plugs, sight glasses and breathers
must be relocated to proper positions, as
shown in Figure 5-3. Failure to change plug
location will result in blower failure and void the
product warranty.
Filling Procedure
See Figure 5-3. See Recommended Lubricants
on page 42
for suggested lubricants and
grease.
1. Remove
the
¿
ll plugs or breathers from both
gear end and drive end plates.
2. Slowly pour oil through the
¿
ll until oil appears
in the oil sight glass. Bring the oil level to the
center of the sight glass.
3. Verify oil level is at proper level in both gear
end and drive end sight glasses.
4. Replace
the
¿
ll plugs or breathers that were
removed in step 1.
Figure 5-3 – Location of Oil Fill, Drain and Level Gauges on CP Series Blowers