Introduction

When it comes to TOUGH, nothing surpasses our Tough Portable System. For almost 30 years this unit has 
been used worldwide throughout the mining community, renown for its extreme durability and low mainte-
nance in some of the world’s harshest conditions. Utilising a Teflon membrane there have been many sceptics, 
tainted by their experience with cheap membrane technology that drifts, is un-repeatable and that fails due to 
tears and ruptures of the membrane that ultimately contaminate and destroy the sensor.

The Turtle Tough - Tough Portable System couldn’t be more different. This German-made technology sets a 
new benchmark in membrane technology. The Ultra Tough Teflon membranes are resilient to highly abrasive 
slurries and maintain excellent repeatability and accuracy. The membrane usually only requires replacement 
annually at the recommended service interval. Calibration stability is an astounding 3-4 months and the units 
simply calibrate in the air, without any need for zero solutions.

The sensor has an extremely fast response, which is critical for applications that demand accuracy or measure 
at high ppm. This is especially true for portable units which are often tank dipped or used to measure grab 
samples. Operators rarely allow the required time for stabilisation, so the fast response of the sensor means 
less human error and high accuracy. The standard unit is capable of 0-40ppm while 0 to 60ppm is optional.

Tough Portable System Dissolved Oxygen meter is equally at home in the laboratory as it is in the field. It has 
been designed with this dual-use in mind and powers directly from a 240Volt mains powered cable for full-
time lab use. Disconnecting it, the unit has full field portability, with a provision of up to 20 hours of use of 
battery backup power, and a long 7.5-metre cable that conveniently winds up onto the back of the unit.

The enclosure is seriously tough. Made from ABS plastics in an IP65 enclosure the major components and 
switches are all replaceable. To this day we still see field serviceable units that are greater than 25 years old. It 
is truly a testament to the quality and longevity of this model, one that has stood the test of time.

Содержание TT-TOUGH-DO-M4M

Страница 1: ...TURTLE TOUGH 1 TURTLE TOUGH turtletoughsensors com MANUAL M4M TOUGH DISSOLVED OXYGEN SYSTEM Dissolved Oxygen...

Страница 2: ...emicals 5 Sensors 5 Introduction 6 Specifications 7 Unpacking 7 Operation Temperature Measurement 8 Temperature Stabilisation Time 8 Dissolved Oxygen Measurement 8 Calibration Calibration Verification...

Страница 3: ...eading Safety Precautions the special safety precautions outlined in other sections must also be observed Warnings used in this manual This manual contains vital information relating to the safety of...

Страница 4: ...wired electrical outlet It is recommended that the outlet is protected by an Residual Current Detector or is in any event in compliance with all local electrical regulations Do not bury electrical su...

Страница 5: ...them CAUTION When handling this equipment the accident prevention regulations applicable on site must be observed and the specified personal protective equipment worn PPE examples of protective cloth...

Страница 6: ...d for zero solutions The sensor has an extremely fast response which is critical for applications that demand accuracy or measure at high ppm This is especially true for portable units which are often...

Страница 7: ...atmosphere Housing IP 65 PVC housing Dimensions 200 x 270 x 250 mm H x W x D approx Weight 2 3 kg approx Field case 385 x 355 x 180 mm H x W x D approx Weight 1 5 kg approx Unpacking Please have a cop...

Страница 8: ...antly kept in the measuring liquid it will not be necessary to observe a temperature stabilisation time The best procedure is to wait until the temperature value on the liquid crystal display remains...

Страница 9: ...nd the membrane have to be dry remove any humidity by dabbing the tip with tissue paper Cover the sensor i e with newspaper to avoid any wind on the tip 2 Wait for at least 15 20 minutes to be sure th...

Страница 10: ...material It is held by means of two red collars 4 and one O Ring 5 During measurements the membrane must not come into contact with sharp objects such as stones or sharp grained sand which might dama...

Страница 11: ...verified by holding the sensor horizontally You should now be able to see an air bubble no larger than 4 mm in the centre of the pressure compensation membrane Should refilling of the electrolyte be r...

Страница 12: ...low since the white wick like insert would otherwise be damaged Doing this voids the warranty 6 Wipe the cathode clean with tissue paper but do not polish it because the scratched surface helps to for...

Страница 13: ...ane until electrolyte appears in all the electrolyte channels Note Never use a needle or other sharp objects to create flow since the white wick like insert would otherwise be damaged Doing this voids...

Страница 14: ...pressure ring nut and screw it on carefully Using the Membrane Positioner Use the Membrane Positioner TT TOUGH DO MP to easily replace the cathode membrane without any wrinkles Follow these steps for...

Страница 15: ...Kit for sensor tip with 10 membranes 3 O Rings and 1 bottle electrolyte solution TT TOUGH DO MEM Refill Kit without electrolyte TT TOUGH DO ELEC Electrolyte Solution 125 ml bottle TT TOUGH DO SWM Refi...

Страница 16: ...faulty installations corrosion or the effects of chemical processes is excluded from this warranty coverage Our agents or representatives may provide you with a life expectancy guide based on similar...

Страница 17: ...service and description of the process Description of the fault and circumstances of the failure Process environmental conditions that may be related to the failure of the sensor Statement as to wheth...

Отзывы: