Installation, Maintenance and Inspection

The  owner  must  ensure  that  all  maintenance,  inspection  and  installation work  is  undertaken  by 

 

authorised and duly qualified personnel who have also studied this manual.

• 

Sensors must always be isolated before starting any work.

• 

Please be aware that the connected sensor(s) and the associated analyser may be controlling 
chemical dosing and as such shutting down the unit without due regard to the systems it is 
controlling can lead to the chemical release.

Impermissible Modes of Operation

Usage other than as described in this manual will lead to the immediate cancellation of the warranty 
and any other manufacturer’s liability.

Unauthorised Modification

Usage other than as described in this manual will lead to the immediate cancellation of the warranty 
and any other manufacturer’s liability.

Chemicals

Should the sensor(s) be in contact with hazardous chemicals, great care must be taken when handling 
them.

CAUTION

When  handling  this  equipment,  the  accident  prevention  regulations  applicable  on-site  must  be 

 

observed and the specified personal protective equipment worn.

 

PPE: examples of protective clothing, gloves and goggles.

DANGER 

 

Fire hazard. No parts are suitable for use in a hazardous rated area. 

Important: 

Please unpack the equipment and ordered accessories carefully in order not to miss small 

parts. Immediately compare the scope of delivery to the delivery note. If there are any discrepancies, 
contact your Turtle Tough Representative.

Sensors

Health and Safety

Before making or breaking any electrical or signal connections, ensure that the instrument is isolated 
from the electrical supply. When handling the sensor please wear the appropriate PPE.

Environmental Considerations

Please use this product in a manner sensitive to the environment and at the end of its life dispose 

 

or recycle in a manner appropriate at that time that complies with local regulations. 

Disconnect 

 

electrical supply 

before working 

 

on this equipment

Appropiate 

 

PPE to be 

 

worn when 

 

in contact 

 

with the 

 

sensor

Take care 

 

when

removing 

 

the sensor

Important

Danger

Caution

Warning

Содержание TT-TOUGH-DO-M4M

Страница 1: ...TURTLE TOUGH 1 TURTLE TOUGH turtletoughsensors com MANUAL M4M TOUGH DISSOLVED OXYGEN SYSTEM Dissolved Oxygen...

Страница 2: ...emicals 5 Sensors 5 Introduction 6 Specifications 7 Unpacking 7 Operation Temperature Measurement 8 Temperature Stabilisation Time 8 Dissolved Oxygen Measurement 8 Calibration Calibration Verification...

Страница 3: ...eading Safety Precautions the special safety precautions outlined in other sections must also be observed Warnings used in this manual This manual contains vital information relating to the safety of...

Страница 4: ...wired electrical outlet It is recommended that the outlet is protected by an Residual Current Detector or is in any event in compliance with all local electrical regulations Do not bury electrical su...

Страница 5: ...them CAUTION When handling this equipment the accident prevention regulations applicable on site must be observed and the specified personal protective equipment worn PPE examples of protective cloth...

Страница 6: ...d for zero solutions The sensor has an extremely fast response which is critical for applications that demand accuracy or measure at high ppm This is especially true for portable units which are often...

Страница 7: ...atmosphere Housing IP 65 PVC housing Dimensions 200 x 270 x 250 mm H x W x D approx Weight 2 3 kg approx Field case 385 x 355 x 180 mm H x W x D approx Weight 1 5 kg approx Unpacking Please have a cop...

Страница 8: ...antly kept in the measuring liquid it will not be necessary to observe a temperature stabilisation time The best procedure is to wait until the temperature value on the liquid crystal display remains...

Страница 9: ...nd the membrane have to be dry remove any humidity by dabbing the tip with tissue paper Cover the sensor i e with newspaper to avoid any wind on the tip 2 Wait for at least 15 20 minutes to be sure th...

Страница 10: ...material It is held by means of two red collars 4 and one O Ring 5 During measurements the membrane must not come into contact with sharp objects such as stones or sharp grained sand which might dama...

Страница 11: ...verified by holding the sensor horizontally You should now be able to see an air bubble no larger than 4 mm in the centre of the pressure compensation membrane Should refilling of the electrolyte be r...

Страница 12: ...low since the white wick like insert would otherwise be damaged Doing this voids the warranty 6 Wipe the cathode clean with tissue paper but do not polish it because the scratched surface helps to for...

Страница 13: ...ane until electrolyte appears in all the electrolyte channels Note Never use a needle or other sharp objects to create flow since the white wick like insert would otherwise be damaged Doing this voids...

Страница 14: ...pressure ring nut and screw it on carefully Using the Membrane Positioner Use the Membrane Positioner TT TOUGH DO MP to easily replace the cathode membrane without any wrinkles Follow these steps for...

Страница 15: ...Kit for sensor tip with 10 membranes 3 O Rings and 1 bottle electrolyte solution TT TOUGH DO MEM Refill Kit without electrolyte TT TOUGH DO ELEC Electrolyte Solution 125 ml bottle TT TOUGH DO SWM Refi...

Страница 16: ...faulty installations corrosion or the effects of chemical processes is excluded from this warranty coverage Our agents or representatives may provide you with a life expectancy guide based on similar...

Страница 17: ...service and description of the process Description of the fault and circumstances of the failure Process environmental conditions that may be related to the failure of the sensor Statement as to wheth...

Отзывы: