The turnstile should carry out the relative actions reliably when the upstream management 
software is used to carry out operations for the turnstile such as rod up/down, open barrier, 
counting  value  of  read/reset  counter.  If  not,  it  is  necessary  to  check  carefully  the 
communications lines and connectors. 

For detail operation method and contents, refer to Appendix A1. 

6. Operation Instruction of the Equipment

Once the mechanical and electrical installation of the turnstile has been completed, it can 
be put into service. 
Check before startup 
6.1 The equipment can only be used after the above test to ensure a normal operation of the 

equipment. 

6.2  It  is  forbidden  for  the  passenger  to  push,  lean  or  pull  the barrier rod  during  the  card 

reading  or  prior  to  the  indicator  changing  into  a  green  lamp.  Otherwise,  the  normal 
operation of equipment may be affected. 

6.3 It is forbidden to sit or press with force on the barrier rod when the equipment is not in 

use, otherwise, the turnstile may be damaged. 

6.4  It  is  recommended  that  the  equipment  not  be  used  directly  in  the  exposed  site,  or  in 

humidity  or corrosive  environment.  Otherwise,  the application  life of  equipment  may 
be  affected  due  to  rain,  humidity  or  corrosive  subject  (for  application  in  outdoor, 
rainproof facilities such as sun shading board should be used). 

6.5

 

For passing, it is only needed for the passenger to push slightly the barrier rod and the 
equipment  will  then  drive  the  barrier  rod  to  move  automatically.  It  is  not  allowed  to 
push the barrier rod with strong force during the passing. 

    Precautions: 

1) Please do not use the system when there is lightning, otherwise the turnstile may be

damaged.

2) It  is  required  to  connect  reliably  the  protection  grounding  of  the  system  to  avoid

accident of personnel injury.

Содержание TPW-321ASP

Страница 1: ...OPERATING MANUAL AUTOMATIC SWING GATE TPW 321ASP...

Страница 2: ...4 3 SYSTEM COMPOSITION 4 5 EQUIPMENT ASSEMBLY AND INSTALLATION 4 5 1 EQUIPMENT INSTALLATION 4 5 2 EQUIPMENT FUNCTIONAL TEST 6 5 3 3 FAR END CONTROL 6 6 OPERATION INSTRUCTION OF THE EQUIPMENT 7 7 REGU...

Страница 3: ...the system It is recommended that the user read carefully the operation manual prior to application of the equipment otherwise your right may be infringed due to an improper application of the equipme...

Страница 4: ...ctro mechanism mounted within the top section of the Automatic Swing Gate and accessible by open the Top Cover Purely mechanical control is also possible 8 It is provided with multiple operation modes...

Страница 5: ...des there are also different types and specifications depending on different read write equipment installed 1200 Figure 1 4 Basic Operation Principle 4 1 Basic Operation Principle When card in card ou...

Страница 6: ...ay flow limit 2 One way reading card the other way barring 4 3 System Composition The product can either be used independently to form a passage or be combined into multiple passages of intelligent ma...

Страница 7: ...undation Drawing for Ground Installation 5 Pull the cable of the heavy current light current through the 3 4 PVC tubes respectively and bury them into the relevant position with cement 6 Move the equi...

Страница 8: ...for unlocking After the pre set time the main controller controls the motor drives the barrier rotate to the limit position and lock automatically the counter will automatically increase 1 at the pass...

Страница 9: ...a green lamp Otherwise the normal operation of equipment may be affected 6 3 It is forbidden to sit or press with force on the barrier rod when the equipment is not in use otherwise the turnstile may...

Страница 10: ...ection grounding of the system to ensure a reliable connection 4 It is required to check regularly the connectors and line connection points to ensure a reliable connection 8 Common Failures and the R...

Страница 11: ...nd sound alarm if passengers get into the gate area without sign in sign out NC mode normal close gate stay in close state gate will open if passenger sign in sign out successfully gate will return to...

Страница 12: ...oor closing time setting the max time for each passenger entering the passage The value effective range is 1 60 unit is second Default 5 4 Entry counter reset clear entry counting value 5 Exit counter...

Страница 13: ...11 Attached Figure 4...

Страница 14: ...12 2 The instructions of turnstile control panel Turnstile control panel instructions shown as Attached Figure 4 Attached Figure 4...

Страница 15: ...panel The common wirings for customer 1 OPEN_R Entrance open signal access dry contact signal 2 OPEN_L Exit open signal access dry contact signal 3 EMO Emergency signal access dry contact signal Conne...

Страница 16: ...ertime waiting time is 2 seconds The control board of turnstiles will send related parameters after received feedback signal Every parameter sent by main board needs the feedback signal address if you...

Страница 17: ...l board successfully corresponding commands can be sent to the control board to set the parameters The control board will send success return signal 0x02 0x44 0x00 0x04 to PC if the setting is success...

Страница 18: ...c tripod turnstiles For detailed command formats please refer to 3 Control Board Receiving Command Below is the flow Chart 2 Control Board Sending Command Control Board Sending Command Format Command...

Страница 19: ...tatus the second word shows exit status 0x30 Controlled Mode 0x31 Free Passing Mode 0x32 Forbidden Passing 0x33 Barrier free passing after swiping card 0x18 0x03 0x30 0x39 0x30 0x39 0x30 0x39 Door clo...

Страница 20: ...x33 Setting working mode of entry exit the first word shows setting entry working mode the second word shows setting exit working mode 0x30 Controlled Mode 0x31 Free Passing Mode 0x32 Forbidden Passin...

Страница 21: ...counting see the sending command format table 0x42 0x01 0x31 0x37 Setting the door opening closing speed ranking 1 7 0x31 0x37 ASCII code of 1 7 inapplicable to tripod turnstiles 0x81 0x01 0x31 0x35...

Страница 22: ...is command the control panel will set the display image of LED panel on both sides according to the command contents and then return to the feedback command The first word refers to LED panel address...