background image

5

EN

CONTROL

 

MODULE

MODULE’S SOFTWARE

Device’s control logic is controlled by the device manufacturer’s software. The manufacturer grants licence to using the software only in 

cooperation with the purchased device and in order to control it. The abovementioned licence is granted by the

manufacturer for products purchased at the authorised distributors only. The licence is granted for:

1.  The time of one month from the devices sales date (on the base of a trade credit).

2. 

An indefinite time - after the payment for the device has been made.

Changes or modifications to the software of whatever kind may be introduced by a detailed and written consent of the device manufac-

turer only. Making changes or modifications to the software without the manufacturer’s consent are not covered by the licence regarding 

using the software. The manufacturer bears no responsibility for proper and safe operation of the device if changes of whatever kind have 

been made to the device’s controlling software, without the device manufacturer’s consent.

The manufacturer reserves the right to introduce changes or updates to the software

. All devices are supplied with a stored 

standard software described in the manual herein. 

TECHNICAL PARAMETERS

Supply power

24VDC / 24VAC

Storage humidity

10  -  90  %RH

Storage temperature 

104 -  185 ºF  ( -40  -  85 ºC )

Operation humidity

10  -  90  %RH

 Operation temperature

-4  -  94 ºF ( -20  -  70 ºC )

Power output load

max 120W

Fuse

5A

• 

Module’s input signals- Short circuit to ground of an appropriate input pin with potential of 5V. Duration should be MIN: 0.2s, MAX: 1s.

• 

Module’s output signals- Relay signals. Depending on which pair of pins is used, output signals can be normal opened or normal

closed. Duration of the output signal can be configured in the driver’s menu.

GLObAL FUNCTIONS

Global functions are functions that are common to all types of devices. Functions specific to a given device series are described in sec-

tions referring to a particular series of devices.

NAVIGATION

Use the rotary encoder to navigate through the menu. Turn it left or right to switch between menu positions. Press the encoder to enter 

the submenu or edit settings values.

1. Display, 2. Encoder

1

2

Содержание BA3 Series

Страница 1: ...1 SG BA3 BR2 GA SERIES DEVICES CONTROL MODULE User s Manual...

Страница 2: ...2 Complete documentation GENERAL INFORMATION PEDESTRIAN TRAFFIC CONTROL DEVICE CONTROL MODULE MONTAGE MAINTENANCE AND SERVICE TECHNICAL DRAWINGS EN...

Страница 3: ...3...

Страница 4: ...PICTOGRAMS CONFIGURATION 7 LICENSE MENU 7 TEST MODE 8 SG SERIES DEVICES 8 DESCRIPTION OF THE CONTROL MODULE TERMINALS 8 SETTINGS MENU 9 ZERO POSITION CONFIGURATION 9 CALIBRATION 10 FIRST RUN 10 BA3 BR...

Страница 5: ...g software without the device manufacturer s consent The manufacturer reserves the right to introduce changes or updates to the software All devices are supplied with a stored standard software descri...

Страница 6: ...of the rotor encoder Vel current velocity of the rotor Back return to the main menu SETTINGS MENU Language configuration Choose the interface language Default setting PL Free entrance function Set the...

Страница 7: ...enu allows you to insert the license key to unlock the license Submitting an in correct key results in a temporary blockade of this menu item Pictograms configuration Pictograms configuration submenu...

Страница 8: ...ck option In devices of the BA3 BR2 and GA series the mode is used only in devices equipped in the rotor s movement support system Caution While starting the test mode no person can be found within th...

Страница 9: ...for a trigger signal If this setting is different than the central one it is recommended to use this setting in combination with the free passage in that direction Default setting cen Fire alarm conf...

Страница 10: ...e when manually moving the arm 3 Check the connection of optical sensors menu parameters A 0 digit means that the barrier is interrupted while 1 means that the barrier is not interrupted 4 The zero po...

Страница 11: ...ETTINGS MENU Coils type There are two options for each coil NOR normal coil during power failure the rotor stays blocked REV reverse coil during power failure the rotor stays unblocked Default setting...

Страница 12: ...he device s motor to identify it s parameters Notice During the calibration nothing shall interrupt the rotor s movement Otherwise the procedure has to be repeated This option is not available in GA a...

Отзывы: